サイクル敵対的生成ネットワークを用いた治療中 CBCT 画像の画質改善
今江 禄一鍛冶 静雄木田 智士松田 佳奈子竹中 重治青木 淳仲本 宗泰尾崎 翔名和 要武山下 英臣中川 恵一阿部 修
著者情報
ジャーナル フリー

2020 年 76 巻 11 号 p. 1173-1184

詳細
抄録

Purpose: Volumetric modulated arc therapy (VMAT) can acquire projection images during rotational irradiation, and cone-beam computed tomography (CBCT) images during VMAT delivery can be reconstructed. The poor quality of CBCT images prevents accurate recognition of organ position during the treatment. The purpose of this study was to improve the image quality of CBCT during the treatment by cycle generative adversarial network (CycleGAN). Method: Twenty patients with clinically localized prostate cancer were treated with VMAT, and projection images for intra-treatment CBCT (iCBCT) were acquired. Synthesis of PCT (SynPCT) with improved image quality by CycleGAN requires only unpaired and unaligned iCBCT and planning CT (PCT) images for training. We performed visual and quantitative evaluation to compare iCBCT, SynPCT and PCT deformable image registration (DIR) to confirm the clinical usefulness. Result: We demonstrated suitable CycleGAN networks and hyperparameters for SynPCT. The image quality of SynPCT improved visually and quantitatively while preserving anatomical structures of the original iCBCT. The undesirable deformation of PCT was reduced when SynPCT was used as its reference instead of iCBCT. Conclusion: We have performed image synthesis with preservation of organ position by CycleGAN for iCBCT and confirmed the clinical usefulness.