Near Infrared LEDs-Based Non-Invasive Blood Sugar Testing for Detecting Blood Sugar Levels on Diabetic Care

Article Preview

Abstract:

Diabetes Mellitus, with its rapid development and various complications that have caused it, has become one of the deadliest diseases in the world. Early detection efforts to raise blood sugar levels can help to avoid a variety of complications. Measuring devices are needed to find out blood sugar levels detect how much sugar is in the blood. The blood sugar measuring device is invasive by taking blood from capillaries tested both in the lab and using portable testing instruments. The use of this tool results in discomfort, pain, and trauma for the patient. The purpose of this study was to determine the degree of sensitivity of the NIR LED sensor on the thumb to the little finger to the reading of light reflections coming out of body tissues.. Currently, the index finger is often used as a medium to find out how much blood sugar is in non-invasive blood sugar measurements. The other four fingers' sensitivity is unknown at this time. Because the use of the index finger, which is located in the middle, can make activities difficult at times, information on the sensitivity level of the other fingers is required. This paper discusses the sensitivity of placing the NIR LED sensor on the five fingers to determine the most sensitive finger with the best response. Based on the testing results of 15 samples, Although the index finger receives the most significant stress, the correlation and linear regression tests show that the thumb has the closest relationship with the R2 = 0.6841. With this research, a test instrument with higher sensitivity for Diabetes can be developed by placing the sensor in a comfortable area. The implication is that the results of this study can be recommended to use the thumb as an alternative to the placement of the NIR LED sensor to measure blood sugar levels non-invasively in DM patients.

You might also be interested in these eBooks

Info:

Pages:

183-191

Citation:

Online since:

March 2022

Export:

Price:

* - Corresponding Author

[1] WHO, Global Report on Diabetes,, (2016).

Google Scholar

[2] Kemenkes, Hasil Utama Riskesdas 2018,, Jakarta, (2018).

Google Scholar

[3] Kementerian Kesehatan Republik Indonesia, Cegah, Cegah, dan Cegah: Suara Dunia Perangi Diabetes,, 2018.

Google Scholar

[4] Kemenkes RI, Permenkes RI Nomor 71 Tahun 2015 tentang Penanggulangan Penyakit Tidak Menular. (2015).

Google Scholar

[5] S. Badriah, J. Sahar, J. Gunawijaya, S. Prasetyo, D. Mariani, and T. Kartilah, Sundanese culture-sensitive family nursing model improves behavior in controlling blood sugar in elderly patients with diabetes,, Enfermería Clínica, vol. 31, pp. S361–S365, Apr. (2021).

DOI: 10.1016/j.enfcli.2020.09.027

Google Scholar

[6] Kemenkes, Riset Kesehatan Dasar 2013,, p.90, Feb. (2013).

Google Scholar

[7] S. Badriah and J. Sahar, Family support in caring for older people with diabetes mellitus: a phenomenology study,, Enfermería Clínica, vol. 28, p.245–249, Feb. (2018).

DOI: 10.1016/s1130-8621(18)30077-9

Google Scholar

[8] S. Badriah, J. Sahar, J. Gunawijaya, and S. Prasetyo, Pampering older people with diabetes in Sundanese culture: A qualitative study,, Enfermería Clínica, vol. 29, p.733–738, Sep. (2019).

DOI: 10.1016/j.enfcli.2019.04.111

Google Scholar

[9] M. S. Abidin, A. Rajak, R. A. Salam, M. M. Munir, and Khairurrijal, Measurement of Glucose in Blood Using a Simple Non Invasive Method,, Mater. Sci. Forum, vol. 827, p.105–109, Aug. (2015).

DOI: 10.4028/www.scientific.net/msf.827.105

Google Scholar

[10] D. Bruen, C. Delaney, L. Florea, and D. Diamond, Glucose Sensing for Diabetes Monitoring: Recent Developments,, Sensors, vol. 17, no. 8, p.1866, Aug. (2017).

DOI: 10.3390/s17081866

Google Scholar

[11] K. Prawiroredjo and E. S. Julian, Comparative study of 940 nm and 1450 nm near infrared sensor for glucose concentration monitoring,, TELKOMNIKA (Telecommunication Comput. Electron. Control., vol. 17, no. 2, p.981, Apr. (2019).

DOI: 10.12928/telkomnika.v17i2.10149

Google Scholar

[12] H. S. Mondal, M. M. Hossain, M. M. H. Mahasin, P. K. Mondal, and M. E. Rahaman, Emerging Applications of Optical Bio-Sensors,, J. Biomimetics, Biomater. Biomed. Eng., vol. 40, p.41–55, Feb. (2019).

DOI: 10.4028/www.scientific.net/jbbbe.40.41

Google Scholar

[13] N. S. Oliver, C. Toumazou, A. E. G. Cass, and D. G. Johnston, Glucose sensors: a review of current and emerging technology,, Diabet. Med., vol. 26, no. 3, p.197–210, Mar. (2009).

DOI: 10.1111/j.1464-5491.2008.02642.x

Google Scholar

[14] Louise Nybacka, FTIR spectroscopy of glucose,, (2016).

Google Scholar

[15] W. Villena Gonzales, A. Mobashsher, and A. Abbosh, The Progress of Glucose Monitoring—A Review of Invasive to Minimally and Non-Invasive Techniques, Devices and Sensors,, Sensors, vol. 19, no. 4, p.800, Feb. (2019).

DOI: 10.3390/s19040800

Google Scholar

[16] F. A. D. Saputra, B. Utomo, S. Sumber, and M. Shahriar Arefin, Development of Measuring Device for Non-Invasive Blood Sugar Levels Using Photodiode Sensor,, Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 2, no. 2, p.74–79, Aug. (2020).

DOI: 10.35882/ijeeemi.v2i2.3

Google Scholar

[17] P. S. Reddy and K. Jyostna, Development of Smart Insulin Device for Non Invasive Blood Glucose Level Monitoring,, in 2017 IEEE 7th International Advance Computing Conference (IACC), 2017, p.516–519.

DOI: 10.1109/iacc.2017.0112

Google Scholar

[18] N. Li et al., A Noninvasive Accurate Measurement of Blood Glucose Levels with Raman Spectroscopy of Blood in Microvessels,, Molecules, vol. 24, no. 8, p.1500, Apr. (2019).

DOI: 10.3390/molecules24081500

Google Scholar

[19] A. T. Priyoti, S. J. Jim, S. Hossain, S. Mahmud, S. Salvin, and A. Bhattacharjee, Non-Invasive Blood Glucose Measurement Using Near Infra-Red Spectroscopy,, in 2019 IEEE R10 Humanitarian Technology Conference (R10-HTC)(47129), 2019, vol. 2019-Novem, p.1–4.

DOI: 10.1109/r10-htc47129.2019.9042473

Google Scholar

[20] B. E. Manurung, H. R. Munggaran, G. F. Ramadhan, and A. P. Koesoema, Non-Invasive Blood Glucose Monitoring using Near-Infrared Spectroscopy based on Internet of Things using Machine Learning,, in 2019 IEEE R10 Humanitarian Technology Conference (R10-HTC)(47129), 2019, vol. 2019-Novem, p.5–11.

DOI: 10.1109/r10-htc47129.2019.9042479

Google Scholar

[21] C. D. Chua, I. M. Gonzales, E. Manzano, and M. C. Manzano, Design and Fabrication of a Non-Invasive Blood Glucometer Using Paired Photo-Emitter and Detector Near-Infrared LEDs,, in DLSU Research Congress, 2014, p.1–7.

Google Scholar

[22] J. Yadav, A. Rani, V. Singh, and B. M. Murari, Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy,, Biomed. Signal Process. Control, vol. 18, p.214–227, (2015).

DOI: 10.1016/j.bspc.2015.01.005

Google Scholar

[23] S. Robiah et al., Infra Red Light Emitting Diode in 1200 nm Range have Moderate Performance in Detecting Glucose in Human Blood Glucose Model,, IOP Conf. Ser. Earth Environ. Sci., vol. 58, no. 2, p.012021, Mar. (2017).

DOI: 10.1088/1755-1315/58/1/012021

Google Scholar

[24] Wemos.cc, D1 mini Lite — WEMOS documentation., [Online]. Available: https: //www.wemos.cc/en/latest/d1/d1_mini_lite.html#technical-specs. [Accessed: 12-Aug-2021].

DOI: 10.57152/ijeere.v2i1.208

Google Scholar

[25] J. Nedoma, M. Fajkus, and R. Martinek, Fiber-Optic Breath Sensors: A Comparison Study,, J. Biomimetics, Biomater. Biomed. Eng., vol. 40, p.56–63, Feb. (2019).

DOI: 10.4028/www.scientific.net/jbbbe.40.56

Google Scholar

[26] M. S. Asekar, Development of Portable Non-Invasive Blood Glucose Measuring Device Using NIR Spectroscopy,, in 2018 Second International Conference on Intelligent Computing and Control Systems (ICICCS), 2018, no. Iciccs, p.572–575.

DOI: 10.1109/iccons.2018.8663039

Google Scholar

[27] P.Muhamaduyasic, K.M. Gopinath, K.Rohini, and R. Sukanesh, a Non-Invasive Blood Glucose Monitoring Device Using Red Laser Light,, Int. Res. J. Eng. Technol., vol. 05, no. 03, p.78–82, (2018).

Google Scholar

[28] B. Javid, F. Fotouhi-Ghazvini, and F. Zakeri, Noninvasive optical diagnostic techniques for mobile blood glucose and bilirubin monitoring,, J. Med. Signals Sensors, vol. 8, no. 3, p.125, (2018).

DOI: 10.4103/jmss.jmss_8_18

Google Scholar