Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor †

1
Meijo University, Nagoya, Japan
2
Toyota Technological Institute, Nagoya, Japan
3
Toyota Motor Corporation, Nagoya, Japan
4
Tohoku University, Sendai, Japan
*
Author to whom correspondence should be addressed.
Presented at the Eurosensors 2017 Conference, Paris, France, 3–6 September 2017.
Proceedings 2017, 1(4), 303; https://doi.org/10.3390/proceedings1040303
Published: 11 August 2017
(This article belongs to the Proceedings of Proceedings of Eurosensors 2017, Paris, France, 3–6 September 2017)

Abstract

:
Tactile sensing is required for assistant robots. A new stacked sensor head was proposed which detects forces and thermal sensations with a nerve-net LSI chip. To measure temperatures and heat flows, the sensor head required a thin and small heater to heat up the sensor head. The features of the polyimide heater are compact, low heat capacity, low power consumption and ease of attaching it to the LSI chip. The polyimide heater consisted of Au 10 nm/Cu 200 nm/Cr 20 nm thickness layers on a polyimide film. The surface of the sensor head heated up to 60 °C by the polyimide heater with 0.3 W. By the Cu thin film polyimide heater, the small stacked sensor head with the nerve-net LSI chip is enable to detect forces, temperatures, and heat flows, simultaneously.

1. Introduction

It is required for upcoming aging society to realize next generation robots such as assistant robots for housework, business work and nursing. The robots will coexist with parsons and assist them. Tactile sensors make the robots to detect contacts with parsons and things, and to grasp and hold them gently and safely. If tactile sensors detect human-like thermal sensing, they are useful for material estimation. The robots are enable to estimate materials of things, such as metals, glasses, clothes and human bodies by contact. And the robots will be able to feel health of patients. Beside an infrared thermo-camera, the tactile sensors detect temperatures of behind objects contiguously. The tactile sensors should cover whole the hands, arms and body of the robots for them to work well.
A special nerve-net LSI chip has advantages in reducing number of wiring and simultaneous measurement with various sensors [1,2] (Figure 1 and Figure 2). The LSI chip was packaged in ceramics for good thermal conductivity and durability (Figure 3). A stacked sensor head with the LSI chip shown in Figure 4 was proposed for detecting forces and thermal sensations. The sensor head was designed to be installed in fingertips of the robots and to detect forces, temperatures, and heat flows by fingertip contacts. For accurate heat flow measurement, a heat insulator covers the sensor head except a carbon sheet top. As the heat flow detection is required to estimate materials, a heater installed into the sensor head is required to make the heat flow. For the heater of the stacked sensor head, the followings are important. The heater is compact as small as 8.5 mm square, low heat capacity, low power consumption, and ease to mount it into the sensor head. Conventional product heaters were not suitable for the above requirements. Compared to silicon substrate, polyimide film is superior to thermal isolation, low heat capacity and flexibility. Therefore, the thin film heater on the polyimide film is suitable for the sensor head. In the previous studies of polyimide heaters [3,4], gold and platinum films were used in practice. However, they were expensive and difficult to be products. We have designed and produced new heaters on a 125 μm thickness polyimide film. Cr and Cu films were compared as the heater material. The electric resistances and TCRs (resistance temperature coefficient) of the heaters were measured. Heating up the sensor head to 60 °C and down to 20 °C experiments were done with the heater. The heater materials and structures were evaluated to get the good thin film heater for the nerve-net tactile sensor [5,6].

2. Design and Fabrication

The small thin film heaters of Cr and Cu films were designed on the polyimide film for the sensor head. The required specifications of heaters are as follows.
  • Area of the heater is smaller than the area of the LSI ceramic package
  • Low power consumption to heat the sensor head surface up to 60 °C
  • Low heat capacity to get high thermal response of the sensor head
  • Easy mounting on the surface of the LSI ceramic package
The heaters were designed as 8.5 mm square. For low power consumption, low thermal capacity, and easy mounting, the polyimide film of 125 μm in thickness was selected as the heater substrate. The polyimide film is low thermal conductivity and flexible material. Cr and Cu films were compared as the heater material. The compositions of both film resistors are shown in Table 1. Line widths of heater patterns were changed from 400 μm to 800 μm.
A fabrication process of the heater was as follows. Firstly, the polyimide film was glued on a silicon wafer with wax and photoresist was coated. Heater patterns of the photoresist on the polyimide film were made by photolithography with a glass mask. The glass mask of the heater is shown in Figure 5. Secondly, metal layers for the resistors and electrodes were formed by a vacuum evaporation as shown in Table 1 and Figure 6. Thirdly, after the heaters on the polyimide film were detached from the silicon wafer, a polyimide tape of 55 μm in thickness was pasted on the both surfaces of the heaters for protection.

3. Results

3.1. Thin Film Morphology and Electric Reistance Results

A photograph of the heater with line width 400 μm is shown in Figure 7. Photomicrographs of the Cr and Cu film heater surfaces are shown in Figure 8. A lot of scratches and particle like dots were seen on the both surface films. Especially, the Cr film heater was damaged by scratches and particle like dots. The Cr film heaters had problems as electrical breaking of wire or very high resistance. The Cu film heaters worked well. Electric resistances of the Cu film heaters were presented in Table 2 in order of patterns as shown in Figure 5. The obtained electrical resistances of the Cu film heaters were about 7 times larger than calculated resistances which were estimated from a reported electrical resistivity of Cu bulk. By the four probes measurement, 90% of the total resistance of the heater was the resistance of the Cu thin film and 10% of the one was an interface resistance between the heater layer and electrode layers.

3.2. Heater Performance Results

The TCRs of the Cu film heater of line width 800 μm were measured and results were shown in Figure 9. Alumel-chromel thermocouples of 0.1 mm in diameter were used for temperature measurement of the heaters. It was found that the TCR of the heater was about 2.2 × 10−3/°C (<60°C) and almost no hysteresis property was obtained. The heater was attached to the LSI ceramics package and temperatures were measured with a setup as shown in Figure 10, while an experiment of heating up and down. The Cu film heater was successfully achieved a required target temperature of above 60 °C at the sensor head surface with only 0.3 W as shown in Figure 11.

4. Conclusions

It was realized that the Cu thin film heater on the polyimide heated up the stacked sensor head successfully. The heater was fabricated with flexible in 8.5 mm square and about 0.2 mm thickness. The obtained electrical resistances of the heater were about 7 times larger than calculated resistances which were estimated from a reported electrical resistivity of Cu bulk. It was found that the TCR of the heater was about 2.2 × 10−3/°C (<60 °C). The heater achieved target temperature 60 °C at the sensor head surface with only 0.3 W, and obtained almost no hysteresis properties. The small sensor head with the nerve-net LSI chip is enable to detect forces, temperatures, and heat flows, simultaneously. The thin film heater and small temperature sensors will be combined to create ultra-small sensor head for robot fingers and artificial robot skin.

Acknowledgments

A part of this work was supported by Toyota Technological Institute Nano Technology Hub in “Nanotechnology Platform Project” sponsored by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan. The present study is supported in part regarding the experiments of thermal sensing by the New Energy and Industrial Technology Development Organization (NEDO). The development of the sensor platform LSI and the integration technology was performed in R&D Center of Excellence for Integrated Microsystems, Tohoku University under the program “Formation of Innovation Center for Fusion of Advanced Technologies” supported by Special Coordination Funds for Promoting Science and Technology with collaboration with Toyota Motor Corporation and Toyota Central R&D Labs., Inc.

Conflicts of Interest

The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.

References

  1. Muroyama, M.; Makihata, M.; Nakano, Y.; Matsuzaki, S.; Yamada, H.; Yamaguchi, U.; Nakayama, T.; Nonomura, Y.; Fujiyoshi, M.; Tanaka, S.; et al. Development of an LSI for Tactile Sensor Systems on the Whole-Body of Robots. IEEJ Trans. Sens. Micromach. 2011, 131, 302–309. [Google Scholar] [CrossRef]
  2. Muroyama, M.; Nakayama, T.; Hata, Y.; Nonomura, Y.; Bartley, T.; Tanaka, S. A CMOS-LSI for a Sensor Network Platform of Social Robot Applications. In Proceedings of the Smart Systems Integration 2016, Munich, Germany, 9–10 March 2016; pp. 320–327. [Google Scholar]
  3. Yu, S.; Wang, S.; Lu, M.; Zuo, L. A novel polyimide based micro heater with high temperature uniformity. Sens. Actuators A 2017, 257, 58–64. [Google Scholar] [CrossRef]
  4. Han, J.S.; Tan, Z.Y.; Sato, K.; Shikida, M. Thermal characterization of micro heater arrays on a polyimide film substrate for fingerprint sensing applications. J. Micromech. Microeng. 2004, 15, 282–289. [Google Scholar] [CrossRef]
  5. Yamadera, H.; Sugimoto, N.; Kageyama, Y. Preparation of MEMS Thin Film Heater by All Dry Processes and Application to GAS Sensor. IEEJ Trans. Sens. Micromach. 2011, 131, 246–250. [Google Scholar] [CrossRef]
  6. Kawato, Y.; Arimura, H.; Kudo, T. Sintering of Conductive Cu Nano Ink by Photo-sintering Process and Observation of Interface between Cu Film and PI. J. Smart Proc. 2013, 2, 173–177. [Google Scholar] [CrossRef]
Figure 1. Image of nerve-net tactile sensing in robot.
Figure 1. Image of nerve-net tactile sensing in robot.
Proceedings 01 00303 g001
Figure 2. Nerve-net tactile sensing systems.
Figure 2. Nerve-net tactile sensing systems.
Proceedings 01 00303 g002
Figure 3. Nerve-net LSI chip packaged in ceramics.
Figure 3. Nerve-net LSI chip packaged in ceramics.
Proceedings 01 00303 g003
Figure 4. Structure of stacked sensor head.
Figure 4. Structure of stacked sensor head.
Proceedings 01 00303 g004
Figure 5. Glass mask of photolithography.
Figure 5. Glass mask of photolithography.
Proceedings 01 00303 g005
Figure 6. Metal layers on polyimide film.
Figure 6. Metal layers on polyimide film.
Proceedings 01 00303 g006
Figure 7. Photograph of the polyimide heater.
Figure 7. Photograph of the polyimide heater.
Proceedings 01 00303 g007
Figure 8. Photomicrographs of the Cr film heater (A) and the Cu film heater (B).
Figure 8. Photomicrographs of the Cr film heater (A) and the Cu film heater (B).
Proceedings 01 00303 g008
Figure 9. TCR measurement of Cu film heater.
Figure 9. TCR measurement of Cu film heater.
Proceedings 01 00303 g009
Figure 10. Heating up and down experimental setup.
Figure 10. Heating up and down experimental setup.
Proceedings 01 00303 g010
Figure 11. Heating up temperatures vs applied power.
Figure 11. Heating up temperatures vs applied power.
Proceedings 01 00303 g011
Table 1. Compositions of Cr and Cu film heaters.
Table 1. Compositions of Cr and Cu film heaters.
StyleComposition of Film
Cr film resistorAu 10 nm/Cr 300 nm/Polyimide 125 μm
Cu film resistorAu 10 nm/Cu 200 nm/Cr 20 nm/Polyimide 125 μm
Common electrodeAu 10 nm/Cu 200 nm/Cr 20 nm
Heater line width400 μm, 600 μm, 700 μm, 800 μm
Table 2. Resistance of the Cu film heater due to linewidth of heater pattern.
Table 2. Resistance of the Cu film heater due to linewidth of heater pattern.
Electric Resistance [Ω]Linewidth 400 μmLinewidth 800 μmLinewidth 600 μmLinewidth 700 μm
Row 1157364845
Row 2136344442
Row 3130344540
Row 4128334339
Average Value138344541
Calculated Value18.45.16.75.8
Average/Calculated Ratio749%679%673%717%

Share and Cite

MDPI and ACS Style

Suganuma, Y.; Sasaki, M.; Nakayama, T.; Muroyama, M.; Nonomura, Y. Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor. Proceedings 2017, 1, 303. https://doi.org/10.3390/proceedings1040303

AMA Style

Suganuma Y, Sasaki M, Nakayama T, Muroyama M, Nonomura Y. Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor. Proceedings. 2017; 1(4):303. https://doi.org/10.3390/proceedings1040303

Chicago/Turabian Style

Suganuma, Yusuke, Minoru Sasaki, Takahiro Nakayama, Masanori Muroyama, and Yutaka Nonomura. 2017. "Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor" Proceedings 1, no. 4: 303. https://doi.org/10.3390/proceedings1040303

Article Metrics

Back to TopTop