Next Article in Journal
Waste Clearance in the Brain and Neuroinflammation: A Novel Perspective on Biomarker and Drug Target Discovery in Alzheimer’s Disease
Next Article in Special Issue
The Evolution of Complex Muscle Cell In Vitro Models to Study Pathomechanisms and Drug Development of Neuromuscular Disease
Previous Article in Journal
A Mechanistic Theory of Development-Aging Continuity in Humans and Other Mammals
Previous Article in Special Issue
Muscle Sonography in Inclusion Body Myositis: A Systematic Review and Meta-Analysis of 944 Measurements
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Non-Invasive Optical Motion Tracking Allows Monitoring of Respiratory Dynamics in Dystrophin-Deficient Mice

1
Translational Molecular Imaging, Max-Planck Institute for Multidisciplinary Sciences, City Campus, 37075 Göttingen, Germany
2
X-ray Based Preclinical Imaging Technologies, Institute for Diagnostic and Interventional Radiology, University Medical Center, 37075 Göttingen, Germany
3
Central Breathing Control, Clinic for Anesthesiology, University Medical Center, 37075 Göttingen, Germany
4
Neuromuscular Disease Research, Clinic for Neurology, University Medical Center, 37075 Göttingen, Germany
5
Clinic for Haematology and Medical Oncology, University Medical Center, 37075 Göttingen, Germany
6
Multiscale Bioimaging—From Molecular Machines to Networks of Excitable Cells, Cluster of Excellence (MBExC), 37075 Göttingen, Germany
7
Institute for Diagnostic and Interventional Radiology, University Hospital, 69120 Heidelberg, Germany
*
Author to whom correspondence should be addressed.
Current address: Biological X-ray Imaging, European Molecular Biology Laboratory, Hamburg Unit c/o DESY, 22607 Hamburg, Germany.
Cells 2022, 11(5), 918; https://doi.org/10.3390/cells11050918
Submission received: 31 December 2021 / Revised: 2 March 2022 / Accepted: 3 March 2022 / Published: 7 March 2022

Abstract

:
Duchenne muscular dystrophy (DMD) is the most common x-chromosomal inherited dystrophinopathy which leads to progressive muscle weakness and a premature death due to cardiorespiratory dysfunction. The mdx mouse lacks functional dystrophin protein and has a comparatively human-like diaphragm phenotype. To date, diaphragm function can only be inadequately mapped in preclinical studies and a simple reliable translatable method of tracking the severity of the disease still lacks. We aimed to establish a sensitive, reliable, harmless and easy way to assess the effects of respiratory muscle weakness and subsequent irregularity in breathing pattern. Optical respiratory dynamics tracking (ORDT) was developed utilising a camera to track the movement of paper markers placed on the thoracic-abdominal region of the mouse. ORDT successfully distinguished diseased mdx phenotype from healthy controls by measuring significantly higher expiration constants (k) in mdx mice compared to wildtype (wt), which were also observed in the established X-ray based lung function (XLF). In contrast to XLF, with ORDT we were able to distinguish distinct fast and slow expiratory phases. In mdx mice, a larger part of the expiratory marker displacement was achieved in this initial fast phase as compared to wt mice. This phenomenon could not be observed in the XLF measurements. We further validated the simplicity and reliability of our approach by demonstrating that it can be performed using free-hand smartphone acquisition. We conclude that ORDT has a great preclinical potential to monitor DMD and other neuromuscular diseases based on changes in the breathing patterns with the future possibility to track therapy response.

1. Introduction

Duchenne muscular dystrophy (DMD) is the most prevalent and one of the most serious muscular dystrophies [1] for which no curative treatment is yet available [2,3]. The cause of DMD is a deletion or loss-of-function mutation in the more than two megabase large dystrophin gene, which leads to the loss of the muscle structure protein of the same name [4,5]. The dystrophin protein, a key component of the dystrophin-associated glycoprotein complex in skeletal muscle cells and cardiomyocytes [4], normally links the actin cytoskeleton to the sarcolemma and the extracellular matrix and thus provides mechanical stability during contraction as well as mechanosignalling to the extracellular matrix [6,7]. The absence of dystrophin leads to a contraction-induced muscle fibre damage, an altered calcium homeostasis with repeated cycles of de- and regeneration and myoinflammation until the muscle tissue is gradually replaced by fatty and fibrotic tissue [1,8,9]. Clinically, DMD patients present with progressive skeletal muscle degradation, a loss of ambulation, progressive cardiomyopathy [10] and a reduction in respiratory function [11]. Cardiopulmonary impairment is significantly involved in the premature death of patients [12,13]. The respiratory dysfunction results from morphological changes of the diaphragm and the auxiliary respiratory muscles [14] and thereby must be routinely assessed in DMD patients to determine the optimal time point for pulmonary respiratory aids and support. Although the standard treatment with glucocorticosteroids and non-pharmacological approaches including an improved management of cardiac function and respiratory support have increased survival of DMD patients by up to 10 to 20 years, the disease is still fatal between the third and fourth decades of life [15,16] Therefore, considerable efforts are undertaken towards targeted mitigation of the causative genetic mutation or compensating for the lack of dystrophin such as read-through [17], exon-skipping [18], vector-mediated gene therapy [19], CRISPR/Cas9 gene editing [20] and cell therapy [21], all aiming to decrease morbidity and mortality and increase the life quality of these patients [22].
The most common mouse model for DMD is the well-established mdx (C57 BL/10 ScSn-Dmdmdx/J (Bl10/mdx))-mouse [23]. The mdx (X-chromosome-linked muscular dystrophy) mouse was discovered spontaneously in a C57 BL/10 ScSn colony [24] and is characterised by a nonsense mutation in Exon 23 which results in a premature stop codon and absence of dystrophin protein [4,25,26,27]. Even though mdx animals have a milder phenotype compared to DMD patients, they exhibit a characteristic DMD pathology of the diaphragm early in the disease phase [24]. The myodystrophic processes of the mdx mouse increase over its lifetime [28].
For optimised use of mdx animals, sensitive and standardised preclinical measurement methods have been developed by the TREAT-NMD network (Translational Research in Europe for the Assessment and Treatment of Neuromuscular Disease; http://www.treat-nmd.eu, accessed 30 December 2021). Terminal or paraclinical measurement parameters such as serum creatine kinase (CK), histological changes in the skeletal muscle and the expression of mediators at the mRNA level are recommended. Other preclinical assessments in mdx mice include motor tests such as determination of grip strength and running wheel analyses. The recommended procedures for respiratory system evaluation are spirometric measurements with a pneumotachometer, intratracheal end-point ventilation and whole-body plethysmography [29].
Respiratory muscle weakness is a known consequence of many neuromuscular diseases. Patients with conditions such as amyotrophic lateral sclerosis (ALS), certain myopathies, myasthenia gravis and muscular dystrophies, including DMD, are found to have abnormal breathing patterns and changes in respiratory dynamics [30,31,32,33]. Latter observation makes monitoring DMD disease progression based on the respiratory dynamics desirable for both, humans and mouse models and has motivated this study.
One option to monitor respiratory dynamics is whole-body plethysmography, which previously has been used to analyse DMD mouse models [34,35,36,37,38,39]. An alternative method is X-ray based lung function (XLF) which relies on planar low dose X-ray imaging [40,41,42]. While the method to this day has been used primarily to monitor mouse models of chronic and inflammatory pulmonary diseases, it, nevertheless, has been shown to be suitable for tracking the progression of respiratory function [41]. However, XLF relies on the use of ionising radiation. While the received dose is relatively small (6 mGy), due to accumulation, XLF is not suitable for long-lasting follow-up studies with repeated measurements. Therefore, the aim of the present study was to establish an alternative optical method that is able to recognise changes of the respiratory dynamics of the mdx phenotype. To achieve this, we developed the optical respiratory dynamics tracking (ORDT) based on camera-enabled tracing of chest surface markers and compared the results with XLF measurements in mdx and wt mice.
ORDT was found to have the following advantages: (1) easy to perform, (2) non-invasive, (3) low cost and (4) featuring commonly available tools and equipment. Moreover, ORDT was successfully able to reproduce XLF derived data, showing a faster expiration in mdx mice compared to wt controls. Additionally, ORDT depicted a clear two-phase expiration pattern present in both mdx and wt mice, and revealed distinct differences in the two-phase expiration behaviours, which was not found in the XLF measurements.

2. Materials and Methods

2.1. Mouse Model and Experimental Design

Mdx mice (C57 BL/10 ScSn mdx) used for breeding were kindly provided by Ralf Herrmann (University of Essen, Germany). Equal numbers of male and female mice were used in mdx and healthy [C57 BL/10 ScSn] control groups. The longitudinal experiment spanned 12 weeks, the measurements were performed on mice at 5, 7, 9, 11, 13 and 17 weeks of age. For the initial measurement at five weeks 5 animals in each group were recruited (n = 5) and 1 wt, 1 mdx mice were sacrificed directly after the measurement for model validation by histological assessment (Figure S1). At 7 weeks, 3 additional mice were added to each group for all following measurements (n = 7). Upon the completion of the timeline, all of the mice continued in another experiment unrelated to this study. The summary of the body masses can be found in Figure S2. For XLF and ORDT measurements, the animals were anaesthetised with 2–3% isoflurane, airflow of 1 L/min of 50:50 mix of air and oxygen. The anaesthesia was titrated to maintain the respiratory intervals at approximately 1400 ms. This interval was chosen due to limiting acquisition frame rate (30 Hz) of the X-ray detector used in the XLF analysis. An additional set of ORDT measurements were performed at approximately 800 ms breathing intervals to compare the effect of deepness of anaesthesia on the functional parameters. ORDT and XLF readings were performed sequentially on the same day on the same animals in both groups. First ORDT measurement was performed on the mouse in supine position, the markers were then removed, and the CT scans were then performed without repositioning the mouse. The experiments were approved by the responsible ethics committee of the state of Lower Saxony, Germany and performed in accordance with the ethical guidelines of the national animal protection law. The colony was maintained by crossing mdx males with mdx females and bred at the central animal facility of the University Medical Center Göttingen. All mice were housed in plastic individually ventilated cages and maintained on a regular diurnal lighting cycle (12:12 light:dark) with ad libitum access to standard rodent food and water.

2.2. Optical Respiratory Dynamics Tracking (ORDT)

For the standard ORDT the breathing motion of anaesthetised mice was recorded by a camera (Basler acA640-90 gc, Basler AG, Ahrensburg, Germany; Pentax Cosmicar TV Lens 25 mm 1:1.4, Ricoh, Tokyo, Japan) acquiring images with 600 by 400 pixels for over 10 s at 100 frames per second (fps) in 8-bit grey value format. Paper markers with a printed black cross-hair pattern (3 mm side length and 1 mm centre diameter) were used. They were placed on the thoracic-abdominal region of the animal and attached to the fur of the mice with double-sided tape. The markers in the video feed were located by a Laplacian of Gaussian particle detection and tracked by Linear Assignment Problem algorithms implemented in the TrackMate plugin for ImageJ [43]. Calculation of the expiration constant was performed in the latest version of XLF software [40].
For smartphone-based ORDT (iORDT), an iPhone 12 (Apple Inc., Cupertino, CA, USA) was used. The breathing motion was recorded freehand in HD 1920 by 1080 pixels using 60 and 240 fps modes. The resulting frame rate for the 240 fps was approximately 177 fps as stated by the smartphone device. The acquired video was motion-corrected (see Supplement for further details) the resulting image sequence was then entered to the same analysis pipeline as in the ORDT approach.

2.3. X-ray Lung Function Measurement

Low dose planar cinematic X-ray images were acquired in anesthetised mice using an in vivo microCT (QuantumFX, Perkin Elmer, Waltham, MA, USA) using the following parameters: field of view 20 mm × 20 mm, tube voltage 90 kV and tube current 40 µA. 1024 images were recorded continuously at 30 fps. Mice were scanned unrestrained and as with the ORDT set up. The X-ray transmission over time in the lung area was measured and the expiration constant was calculated using latest version of the XLF software [40].

2.4. Statistical Analysis

All calculated parameters were analysed by mixed-effects model with p < 0.05 significance level. Šídák’s multiple comparisons test was performed to find the differences between mdx and wt groups on individual measurement days. Statistical analysis was performed in Graphpad Prism version 9.2.0 (GraphPad Inc., San Diego, CA, USA).

3. Results

3.1. Optical Respiratory Dynamics Tracking (ORDT) Workflow and Its Comparison to XLF

To perform the optical measurement, the following set-up was established (Figure 1A). The mouse was positioned lying on its back with its nose exposed to isoflurane anaesthesia via a mask. The camera was placed 25 cm cranial and 10 cm anterior to the anaesthetised mice and at 40° facing the abdomen. Four paper markers were positioned in the thoracic-abdominal region of the mouse in order to capture possible phase shifts in the chest motion across different quadrants of the recorded area. The markers were designed with a visible cross-hair pattern for easy camera detection. Thus, four markers were attached: abdominal marker placed on the umbilicus (north, N), sternum marker (south, S) and the 12th rib region on each side (east, E, west, W). In order to parametrise the optical recordings, the markers had to be identified and traced over time. For every marker ∆y and ∆x were calculated as anterior-posterior and sinister-dexter displacements over time. It was further assumed that the total displacement of the markers in each location represents the state of the chest expansion. Due to the shape of the mouse and the marker placement, the analysis cannot be performed considering the displacement in the original y or x axis alone. Therefore, the data for each marker individually was projected into the cardinal direction of the movement (y’) using a Karhunen–Loéve Transformation. To compensate for low-frequency artefacts associated with setup vibration, the resulting traces were filtered, corrected for background and normalised. We applied an adaptive moving average filter with a filter window of w. Since a standard moving average filter Fm may alter the shape of the curve, a weighted moving average filter Fw was applied to penalise points that represent the breathing peak. This approach successfully removed background variations without interfering with the shape of the peak.
F m t   =   1 w   i = w / 2 w / 2 y t + i
F w t   =   1 G t   i = w / 2 w / 2 ( y t + i y t + i     F m t + i   +   0.1 )
G t   =   i = w / 2 w / 2 y t + i     F m t + i   +   0.1
Fw was then subtracted from y’ and the result was scaled to a dynamic range between 0 and 1. Breathing peaks were identified using a threshold of 30%. The starting point and the end-point of a breathing event were defined as local minima in the approximated 2nd derivative of the function prior to the breathing peak. Examples of the resulting exemplary relative marker displacement (rmd) traces of a wt mouse at 5 weeks (38 days) of age from each marker are shown in Figure 1B. The appearance of the breathing peaks in N, W and E traces is consistent, confirming that the cardinal displacement obtained by the performed procedure represents the expanding breathing motion. Since the S marker is located more cranial than the rest of the markers but is still at the caudal end of the sternum, its movement is affected by the movement of the thorax and the abdomen. The biphasic behaviour can be attributed to the placement of the marker on the chest region where the diaphragm passes twice in a single breathing cycle. Additionally, a more prominent pulse wave generated by the heart is seen as a high-frequency modulation in the baseline.
The breathing traces obtained by ORDT were compared to XLF breathing measurements, which are based on the modulation of the averaged X-ray transmission in the lung region. An example of XLF recording from a wt mouse is shown in Figure 2 with selected X-ray transmission regions of interest in right and left lungs displayed in panel A. Obtained average transmission traces are shown in panel B. It is evident that the shape of the breathing events in the traces obtained by ORDT is closely recapitulated by the XLF derived traces. High-frequency modulation present in the baseline of the S trace can be spotted in the XLF trace derived from the left lung region as well due to heart proximity.

3.2. Expiratory Dynamics Measured by ORDT Reproduce Expiratory Constant Differences Found by XLF

To validate whether the ORDT approach is able to detect the DMD/mdx typical phenotype of respiratory neuromuscular weakness and to establish its sensitivity towards respiratory dynamic changes, ORDT derived traces were compared to an established XLF measurement [40]. According to the existing XLF procedure, all expiration segments from a single measurement were combined and a function (Equation (4)) was fitted ensuring the coefficient of determination to be >0.9. Expiration constant (k) was calculated for the XLF derived expiration segments in the right lung and for ORDT derived expiration segments from N, W and E markers. There were no significant differences between N, W, E k values (data not shown), therefore only the N marker is further reported on. Figure 3 shows the computed values for XLF (right lung) and ORDT (N) in mdx and wt mice over the period of 5 to 17 weeks of age.
A t   =   A 0 e k · t 2 + b
XLF derived k was found to be significantly higher in mdx mice compared to wt at all observed timepoints, with higher k indicating steeper expiratory function (Figure 3B). ORDT derived k was found to be significantly higher in mdx mice compared to wt from 7 to 17 weeks of age (Figure 3A). For both XLF and ORDT no significant changes with time were observed in either mdx or wt groups.

3.3. ORDT Identifies Two-Step Expiratory Behaviour which Differs between mdx and wt

The simple calculation of the expiration constant revealed the differences in the expiratory dynamics between mdx and wt in both XLF and ORDT measurements. However, when comparing the shapes of the breathing peaks obtained by ORDT (Figure 1B) and XLF (Figure 2B) it is evident that ORDT derived expiratory segments display a two-step behaviour with a fast descending phase immediately at the beginning of expiration followed by a slow phase. The same phenomenon cannot be observed by XLF due to the limitation of the sampling rate which is 3 times smaller than that of ORDT. Figure 4 shows representative traces of mdx (A) and wt (B) mice obtained by ORDT. Evidently, the two-phase expiratory behaviour is observed in both phenotypes, however, the distribution of the phases differs with mdx slow expiratory phase beginning a lot later in the breathing event which we termed the ‘dampening point’. Since the function native to the XLF analysis pipeline assumes a single Gaussian (Equation (4)), it may not be the best representation of the two-phase expiration data obtained by ORDT. Therefore, the dampening point was defined as the relative marker displacement (rmd) corresponding to the absolute minimum in the third derivative of a fitted sum of Gaussians (Equation (5)). Furthermore, the relative amplitude of the fast expiratory phase was quantified as the difference between maximum relative marker displacement (rmdmax) and the relative marker displacement of the dampening point (rmddp) (Figure S3). In line with the expiration constant observation, amplitude of the fast expiratory phase was found to be significantly larger in mdx mice when compared to wt at all observed time points, except for week 5 (Figure 4C).
D t   =   A 0 e k 1 · t 2 + L 0 e k 2 · t 2 + b
Additionally, the area under the curve (AuC) was calculated by integration of the aforementioned function from the last minimum before the breathing event to 30% of the maximum at the end of the breathing event. AuC was found to be significantly higher in wt mice compared to mdx mice at all observed time points except at 5 weeks (Figure 4D).
The symmetry of the breathing in mdx mice is of particular interest since DMD affected patients are known to exhibit signs of paradoxical breathing [44,45,46], which is defined by the changes in phase between the chest and the abdomen. Thus, simultaneity of the local maxima of the inspiration was analysed by means of ORDT. Here particularly both the left-right symmetry across the sagittal plane of west and east markers and the cranial-caudal continuity of the south and north markers were of interest. No significant phase shifts between any of the marker positions in either right-left or cranial-caudal movement for either of the groups were observed. With these findings, no evidence of paradoxical or otherwise notable breathing asymmetry was detected at all observed time points (data not shown). Additionally, we found no significant differences in the amplitude of displacement between mdx and wt for any of the markers or the calculated inspiration times (data not shown). When comparing different breathing intervals, there were no significant differences between 1400 ms and 800 ms breathing intervals in the same group in any of the measured parameters (Figure S4).

3.4. iORDT Reveals the Importance of the Sampling Rate in Diseased Phenotype Differentiation

The possibility to simplify the ORDT approach further was explored, and a smartphone-compatible version of the protocol was developed (iORDT). A smartphone was used to provide the following advantages: (1) no additional equipment is required, (2) the recordings are streamed directly to the device’s memory and (3) it has a capability of recording with high sampling rates. The setup was modified by including stationary markers for the possibility of motion correction (Figure 5A). The parameters expiration constant k (Figure 5B), relative fast expiratory phase amplitude (Figure 5C) and AuC (Figure 5D) were derived as described above from 60 and 177 Hz smartphone recordings. k has shown better segregation of the phenotypes at 177 Hz, while at 60 Hz this difference was no longer evident. Additionally, the changes in k across different recording frequencies were prominent. Amplitude of the fast expiratory phase remained segregated between phenotypes at all recorded frame rates. AuC has remained different between mdx and wt mice, similarly to k it changed across different recording frequencies.

4. Discussion

Here we developed a novel, simple, low cost and non-invasive approach to track respiratory dynamics based on optical imaging utilising a camera and markers placed on the thoracic-abdominal region in the mdx mouse model of Duchenne muscular dystrophy. ORDT was for the first time applied to successfully differentiate breathing behaviour of diseased mdx mice from healthy controls. When ORDT was compared with the established XLF method and analysed according to the same principle [40,41,42], we found significantly steeper expiration in mdx mice compared to controls at all measured time points beginning with the 7th week from birth as observed by the calculated expiration constant (k). Therefore, ORDT was able to reproduce XLF results without the need for X-ray dose exposure. Evidently, while XLF relies on changes in X-ray attenuation inside the lung, essentially quantifying the shifts in lung transparency (how much air is in the lungs) during breathing, ORDT describes the dynamic expansion state of the chest and abdomen. Fibrotic remodelling of the diaphragm with loss of function is a known consequence of mdx disease [24,47,48,49]. Additionally, previous findings report on anatomical changes of the skeletal structure such as increased spine curvature (kyphosis) [50]. Others further report remodelling in mdx intercostal muscles and recruitment of accessory musculature for breathing assistance with the progression of the disease [51,52]. Therefore, a steeper expiratory phase in mdx mice displayed by ORDT is likely an observed cumulative effect due to pathological remodelling on the microscopic level and changes in macroscopic anatomy leading to altered pressure differentials and musculature contributions, which may not be captured by XLF to the full extent.
Interestingly, ORDT has shown a distinct two-phase expiration pattern in both mdx and wt mice which was not evident in XLF measurements. While the wt mice had almost equally distributed fast- and slow-phases, mdx mice displayed a less prominent slow-phase and a significantly larger fast-expiration-phase as shown by the dampening point calculation. Previously, reports on post-inspiratory contractile electrical activity of the diaphragm have been made [53,54,55,56]. Pellegrini et al. state that this activity is responsible for the acute dampening of the elastic recoil produced by the lung during expiration and actively prevents its collapse [53]. It is feasible that with the weakening of the diaphragm muscle in mdx mice, while the inspiratory motion remains intact, potentially due to use of accessory inspiratory muscles, the post-inspiratory contractility of the diaphragm appears critically affected and is overwhelmed by the elastic recoil of the lung.
The data from functional breathing measurement in mdx mice is not equivocal. Several sources describe a reduction in tidal volumes in mdx at 2, 3 and 6 months of age [36,37,39]. Quindry et al. report no functional differences between 2-month-old mdx and wt mice [39]. Roberts et al. have shown no difference in inspiration time between mdx and wt mice at 4, 9 and 16 weeks of age, but found that the peak expiratory flow was significantly higher in mdx with retained expiration times at the observed time points [57]. Other methods to monitor breathing dynamics include respiratory inductance plethysmography (RIP), which uses elastic resistance bands placed around the top chest and the abdomen [58,59,60]. The method was recently employed in the golden retriever dystrophy model [61]. The expiratory flow ratios of young and adult dogs were found to be elevated, pointing to increased expiratory recoil. The faster termination of the respiratory cycle detected with ORDT with expiration constant measurement is in line with these observations.
It should be noted that the periods of inspiration and expiration in the ORDT approach are defined by the maximum and minimum positions of the relative marker displacement. It is known that the breathing contractile musculature generates pressure gradients that lead to flow of air in and out of the lungs. Thus, inspiration/expiration phases defined for ORDT are not strictly the same phases defined by classical volume and flow representations. Therefore, a further investigation with plethysmography calibration is necessary to elucidate how the different expiratory behaviour between mdx and wt seen in ORDT is represented in a functional sense.
In this study, all ORDT derived measurements were not significantly different on the first measurement day at 5 weeks of age since large variability in the values was detected. It is known that mdx diaphragms experience peak inflammation at 4 weeks for age [62], it is therefore feasible that the effect on the diaphragm immediately following inflammation was not fully established in all animals by week 5 or a permanent fibrosis was present. The amplitude of the fast expiratory phase in the mdx mice appears to follow an upward trend over time. While no progression in the observed time frame has been reported previously, a further investigation over a longer time period may be helpful in elucidating the role of the two-phase expiration on overall course of the disease.
Since many neuromuscular disorders such as amyotrophic lateral sclerosis (ALS), certain myopathies and myasthenia gravis also display abnormal breathing dynamics [30], we believe that a comparative study using ORDT in different mouse models of neuromuscular disorders would be of great interest. Additionally, the approach may prove to be feasible in human subjects. Great care has to be taken when addressing translatability into patients, since the relationship between chest/abdomen surface and lung pressure-volume dynamics largely vary from a highly compliant mouse chest [63]. Further, we have shown that ORDT is possible with a smartphone. The use of personal devices such as smartphones and tablets has been a rising interest in research and medicine. The opportunity to diagnose and monitor certain diseases directly from home by a commonly available personal device is of large interest.
To conclude, we established a non-invasive and easy to use method, ORDT, that is able to distinguish diseased mdx phenotype by breathing dynamics. We were able to derive two distinct expiration phases that differ between mdx and wt mice. Further investigation will be made in order to understand how these observations correspond to functional lung volume and airflow. Since the approach is based on the assessment of the dynamics of the body surface, thereby detecting abnormal breathing patterns observed in many other neuromuscular disorders, ORDT has future potential to become an easy technique for preclinical monitoring of disease severity as well as tracking the response and efficacy to therapeutic intervention.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/cells11050918/s1, Figure S1: Validation of the mdx model by histological and CT assessments. Figure S2: Summary of mouse body mass. Figure S3: Detailed representation of the fast expiratory phase amplitude calculation. Figure S4: Comparison of expiration constant k (top) and relative fast expiratory phase amplitude (dp) (bottom) at 800 ms and 1400 ms breathing intervals.

Author Contributions

Conceptualization, C.D.; methodology, A.S. and C.D.; software, A.S. and C.D.; validation, A.S., J.A., S.H. and C.D.; formal analysis, A.S., J.A., S.H. and C.D.; investigation, A.S. and M.A.M.; data curation, A.S.; resources, J.Z. and F.A.; writing—original draft preparation, A.S. and J.A.; writing—review and editing, S.H., M.A.M., J.Z., F.A. and C.D.; visualization, A.S. and J.A.; supervision, F.A. and C.D.; project administration, A.S. and C.D.; funding acquisition, A.S. and F.A. All authors have read and agreed to the published version of the manuscript.

Funding

No funding to declare.

Institutional Review Board Statement

All animal in-vivo procedures were performed in compliance with the guidelines of the European Directive (2010/63/EU) and the German animal ethics regulations and were approved by the local ethics office (Niedersächsisches Landesamt für Verbraucherschutz und Lebensmittelsicherheit, LAVES, ethics approval 33.9-42502-04-18/2763. Furthermore, the study was carried out in compliance with the ARRIVE guidelines https://arriveguidelines.org/ (accessed on 30 December 2021).

Informed Consent Statement

Not applicable.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Acknowledgments

The authors thank Sarah Garbode, Bärbel Heidrich, Regine Kruse and Iris Iben for technical assistance in animal handling and histological processing. J.Z. is member of the European Reference Network for Rare Neuromuscular Diseases (ERN EURO-NMD). S.H. is partially funded by DFG (Hu/97/13-1). This work was supported by the “Multiscale Bioimaging (MBExC) Cluster of Excellence EXC 2067/1 – 39072994 (DFG).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Emery, A.E. Population Frequencies of Inherited Neuromuscular Diseases—A World Survey. Neuromuscul. Disord. 1991, 1, 19–29. [Google Scholar] [CrossRef]
  2. Farini, A.; Sitzia, C.; Erratico, S.; Meregalli, M.; Torrente, Y. Influence of Immune Responses in Gene/Stem Cell Therapies for Muscular Dystrophies. BioMed Res. Int. 2014, 2014, 818107. [Google Scholar] [CrossRef] [PubMed]
  3. Łoboda, A.; Dulak, J. Muscle and Cardiac Therapeutic Strategies for Duchenne Muscular Dystrophy: Past, Present, and Future. Pharmacol. Rep. 2020, 72, 1227–1263. [Google Scholar] [CrossRef] [PubMed]
  4. Hoffman, E.P.; Brown, R.H.; Kunkel, L.M. Dystrophin: The Protein Product of the Duchenne Muscular Dystrophy Locus. Cell 1987, 51, 919–928. [Google Scholar] [CrossRef]
  5. Bonilla, E.; Schmidt, B.; Samitt, C.E.; Miranda, A.F.; Hays, A.P.; De Oliveira, A.B.S.; Chang, H.W.; Servidei, S.; Ricci, E.; Younger, D.S.; et al. Normal and Dystrophin-Deficient Muscle Fibers in Carriers of the Gene for Duchenne Muscular Dystrophy. Am. J. Pathol. 1988, 133, 440–445. [Google Scholar]
  6. Ibraghimov-Beskrovnaya, O.; Ervasti, J.M.; Leveille, C.J.; Slaughter, C.A.; Sernett, S.W.; Campbell, K.P. Primary Structure of Dystrophin-Associated Glycoproteins Linking Dystrophin to the Extracellular Matrix. Nature 1992, 355, 696–702. [Google Scholar] [CrossRef]
  7. Ervasti, J.M. Dystrophin, Its Interactions with Other Proteins, and Implications for Muscular Dystrophy. Biochim. Biophys. Acta BBA Mol. Basis Dis. 2007, 1772, 108–117. [Google Scholar] [CrossRef]
  8. Deconinck, N.; Dan, B. Pathophysiology of Duchenne Muscular Dystrophy: Current Hypotheses. Pediatr. Neurol. 2007, 36, 1–7. [Google Scholar] [CrossRef]
  9. Villalta, S.A.; Deng, B.; Rinaldi, C.; Wehling-Henricks, M.; Tidball, J.G. IFN-γ Promotes Muscle Damage in the Mdx Mouse Model of Duchenne Muscular Dystrophy by Suppressing M2 Macrophage Activation and Inhibiting Muscle Cell Proliferation. J. Immunol. 2011, 187, 5419–5428. [Google Scholar] [CrossRef]
  10. Nigro, G.; Comi, L.I.; Politano, L.; Bain, R.J.I. The Incidence and Evolution of Cardiomyopathy in Duchenne Muscular Dystrophy. Int. J. Cardiol. 1990, 26, 271–277. [Google Scholar] [CrossRef]
  11. Siegel, I.M. Pulmonary Problems in Duchenne Muscular Dystrophy. Diagnosis, Prophylaxis, and Treatment. Phys. Ther. 1975, 55, 160–162. [Google Scholar] [CrossRef]
  12. Bushby, K.; Finkel, R.; Birnkrant, D.J.; Case, L.E.; Clemens, P.R.; Cripe, L.; Kaul, A.; Kinnett, K.; McDonald, C.; Pandya, S.; et al. Diagnosis and Management of Duchenne Muscular Dystrophy, Part 1: Diagnosis, and Pharmacological and Psychosocial Management. Lancet Neurol. 2010, 9, 77–93. [Google Scholar] [CrossRef]
  13. Ryder, S.; Leadley, R.M.; Armstrong, N.; Westwood, M.; de Kock, S.; Butt, T.; Jain, M.; Kleijnen, J. The Burden, Epidemiology, Costs and Treatment for Duchenne Muscular Dystrophy: An Evidence Review. Orphanet J. Rare Dis. 2017, 12, 79. [Google Scholar] [CrossRef]
  14. Pradhan, S.; Mittal, B. Infraspinatus Muscle Hypertrophy and Wasting of Axillary Folds as the Important Signs in Duchenne Muscular Dystrophy. Clin. Neurol. Neurosurg. 1995, 97, 134–138. [Google Scholar] [CrossRef]
  15. Birnkrant, D.J.; Bushby, K.; Bann, C.M.; Apkon, S.D.; Blackwell, A.; Colvin, M.K.; Cripe, L.; Herron, A.R.; Kennedy, A.; Kinnett, K.; et al. Diagnosis and Management of Duchenne Muscular Dystrophy, Part 3: Primary Care, Emergency Management, Psychosocial Care, and Transitions of Care across the Lifespan. Lancet Neurol. 2018, 17, 445–455. [Google Scholar] [CrossRef]
  16. Eagle, M.; Bourke, J.; Bullock, R.; Gibson, M.; Mehta, J.; Giddings, D.; Straub, V.; Bushby, K. Managing Duchenne Muscular Dystrophy—The Additive Effect of Spinal Surgery and Home Nocturnal Ventilation in Improving Survival. Neuromuscul. Disord. 2007, 17, 470–475. [Google Scholar] [CrossRef]
  17. Bushby, K.; Finkel, R.; Wong, B.; Barohn, R.; Campbell, C.; Comi, G.P.; Connolly, A.M.; Day, J.W.; Flanigan, K.M.; Goemans, N.; et al. Ataluren Treatment of Patients with Nonsense Mutation Dystrophinopathy. Muscle Nerve 2014, 50, 477–487. [Google Scholar] [CrossRef]
  18. Mendell, J.R.; Rodino-Klapac, L.R.; Sahenk, Z.; Roush, K.; Bird, L.; Lowes, L.P.; Alfano, L.; Gomez, A.M.; Lewis, S.; Kota, J.; et al. Eteplirsen for the Treatment of Duchenne Muscular Dystrophy. Ann. Neurol. 2013, 74, 637–647. [Google Scholar] [CrossRef]
  19. Manini, A.; Abati, E.; Nuredini, A.; Corti, S.; Comi, G.P. Adeno-Associated Virus (AAV)-Mediated Gene Therapy for Duchenne Muscular Dystrophy: The Issue of Transgene Persistence. Front. Neurol. 2022, 12, 814174. [Google Scholar] [CrossRef]
  20. Olson, E.N. Toward the Correction of Muscular Dystrophy by Gene Editing. Proc. Natl. Acad. Sci. USA 2021, 118, e2004840117. [Google Scholar] [CrossRef]
  21. Sun, C.; Serra, C.; Lee, G.; Wagner, K.R. Stem Cell-Based Therapies for Duchenne Muscular Dystrophy. Exp. Neurol. 2020, 323, 113086. [Google Scholar] [CrossRef] [PubMed]
  22. Bladen, C.L.; Salgado, D.; Monges, S.; Foncuberta, M.E.; Kekou, K.; Kosma, K.; Dawkins, H.; Lamont, L.; Roy, A.J.; Chamova, T.; et al. The TREAT-NMD DMD Global Database: Analysis of More than 7000 Duchenne Muscular Dystrophy Mutations. Hum. Mutat. 2015, 36, 395–402. [Google Scholar] [CrossRef] [PubMed]
  23. Grounds, M.D.; Radley, H.G.; Lynch, G.S.; Nagaraju, K.; De Luca, A. Towards Developing Standard Operating Procedures for Pre-Clinical Testing in the Mdx Mouse Model of Duchenne Muscular Dystrophy. Neurobiol. Dis. 2008, 31, 1–19. [Google Scholar] [CrossRef] [PubMed]
  24. Stedman, H.H.; Sweeney, H.L.; Shrager, J.B.; Maguire, H.C.; Panettieri, R.A.; Petrof, B.; Narusawa, M.; Leferovich, J.M.; Sladky, J.T.; Kelly, A.M. The Mdx Mouse Diaphragm Reproduces the Degenerative changes of Duchenne muscular dystrophy. Nature 1991, 352, 536–539. [Google Scholar] [CrossRef]
  25. Ryder-Cook, A.S.; Sicinski, P.; Thomas, K.; Davies, K.E.; Worton, R.G.; Barnard, E.A.; Darlison, M.G.; Barnard, P.J. Localization of the Mdx Mutation within the Mouse Dystrophin Gene. EMBO J. 1988, 7, 3017–3021. [Google Scholar] [CrossRef]
  26. Sicinski, P.; Geng, Y.; Ryder-Cook, A.S.; Barnard, E.A.; Darlison, M.G.; Barnard, P.J. The Molecular Basis of Muscular Dystrophy in the Mdx Mouse: A Point Mutation. Science 1989, 244, 1578–1580. [Google Scholar] [CrossRef]
  27. Bulfield, G.; Siller, W.G.; Wight, P.A.; Moore, K.J. X Chromosome-Linked Muscular Dystrophy (Mdx) in the Mouse. Proc. Natl. Acad. Sci. USA 1984, 81, 1189–1192. [Google Scholar] [CrossRef]
  28. Lefaucheur, J.P.; Pastoret, C.; Sebille, A. Phenotype of Dystrophinopathy in Old Mdx Mice. Anat. Rec. 1995, 242, 70–76. [Google Scholar] [CrossRef]
  29. Khurana, T.J. Experimental Protocols for DMD Animal Models/Respiratory System Evaluation. Available online: https://treat-nmd.org/resources-support/research-overview/preclinical-research/experimental-protocols-for-dmd-animal-models/ (accessed on 29 December 2021).
  30. Gilchrist, J.M. Overview of Neuromuscular Disorders Affecting Respiratory Function. Semin. Respir. Crit. Care Med. 2002, 23, 191–200. [Google Scholar] [CrossRef]
  31. Bourke, S.C.; Gibson, G.J. Sleep and Breathing in Neuromuscular Disease. Eur. Respir. J. 2002, 19, 1194–1201. [Google Scholar] [CrossRef]
  32. Sahni, A.S.; Wolfe, L. Respiratory Care in Neuromuscular Diseases. Respir. Care 2018, 63, 601–608. [Google Scholar] [CrossRef]
  33. Pfeffer, G.; Povitz, M. Respiratory Management of Patients with Neuromuscular Disease: Current Perspectives. Degener. Neurol. Neuromuscul. Dis. 2016, 6, 111–118. [Google Scholar] [CrossRef]
  34. Ishizaki, M.; Suga, T.; Kimura, E.; Shiota, T.; Kawano, R.; Uchida, Y.; Uchino, K.; Yamashita, S.; Maeda, Y.; Uchino, M. Mdx Respiratory Impairment Following Fibrosis of the Diaphragm. Neuromuscul. Disord. 2008, 18, 342–348. [Google Scholar] [CrossRef]
  35. Burns, D.P.; Edge, D.; O’Malley, D.; O’Halloran, K.D. Respiratory Control in the Mdx Mouse Model of Duchenne Muscular Dystrophy. Adv. Exp. Med. Biol. 2015, 860, 239–244. [Google Scholar] [CrossRef]
  36. Burns, D.P.; Canavan, L.; Rowland, J.; O’Flaherty, R.; Brannock, M.; Drummond, S.E.; O’Malley, D.; Edge, D.; O’Halloran, K.D. Recovery of Respiratory Function in Mdx Mice Co-Treated with Neutralizing Interleukin-6 Receptor Antibodies and Urocortin-2. J. Physiol. 2018, 596, 5175–5197. [Google Scholar] [CrossRef]
  37. Burns, D.P.; Roy, A.; Lucking, E.F.; McDonald, F.B.; Gray, S.; Wilson, R.J.; Edge, D.; O’Halloran, K.D. Sensorimotor Control of Breathing in the Mdx Mouse Model of Duchenne Muscular Dystrophy. J. Physiol. 2017, 595, 6653–6672. [Google Scholar] [CrossRef]
  38. Quindry, J.C.; Ballmann, C.G.; Epstein, E.E.; Selsby, J.T. Plethysmography Measurements of Respiratory Function in Conscious Unrestrained Mice. J. Physiol. Sci. 2016, 66, 157–164. [Google Scholar] [CrossRef]
  39. Huang, P.; Cheng, G.; Lu, H.; Aronica, M.; Ransohoff, R.M.; Zhou, L. Impaired respiratory function in mdx and mdx/utrn+/ mice. Muscle Nerve 2011, 43, 263–267. [Google Scholar] [CrossRef]
  40. Khan, A.; Markus, A.; Rittmann, T.; Albers, J.; Alves, F.; Hülsmann, S.; Dullin, C. Simple Low Dose Radiography Allows Precise Lung Volume Assessment in Mice. Sci. Rep. 2021, 11, 4163. [Google Scholar] [CrossRef]
  41. Dullin, C.; Markus, M.A.; Larsson, E.; Tromba, G.; Huelsmann, S.; Alves, F. X-ray Based Lung Function Measurement—A Sensitive Technique to Quantify Lung Function in Allergic Airway Inflammation Mouse Models. Sci. Rep. 2016, 6, 36297. [Google Scholar] [CrossRef]
  42. Markus, M.A.; Borowik, S.; Reichardt, M.; Tromba, G.; Alves, F.; Dullin, C. X-ray-Based Lung Function Measurement Reveals Persistent Loss of Lung Tissue Elasticity in Mice Recovered from Allergic Airway Inflammation. Am. J. Physiol.-Lung Cell. Mol. Physiol. 2017, 313, L763–L771. [Google Scholar] [CrossRef]
  43. Ershov, D.; Phan, M.-S.; Pylvänäinen, J.W.; Rigaud, S.U.; Blanc, L.L.; Charles-Orszag, A.; Conway, J.R.W.; Laine, R.F.; Roy, N.H.; Bonazzi, D.; et al. Bringing TrackMate into the Era of Machine-Learning and Deep-Learning. bioRxiv 2021. [Google Scholar] [CrossRef]
  44. Marques, L.; de Freitas Fregonezi, G.A.; Marcelino, A.A.; Teixeira Dourado, E.M., Jr.; Sarmento, A.; Pennati, F.; Aliverti, A.; Resqueti, V.R. Thoracoabdominal Asynchrony and Paradoxical Motion in Duchenne Muscular Dystrophy and Healthy Subjects during Cough: A Case Control Study. Pediatr. Pulmonol. 2021, 56, 2136–2145. [Google Scholar] [CrossRef]
  45. LoMauro, A.; D’Angelo, M.G.; Aliverti, A. Assessment and Management of Respiratory Function in Patients with Duchenne Muscular Dystrophy: Current and Emerging Options. Ther. Clin. Risk Manag. 2015, 11, 1475–1488. [Google Scholar] [CrossRef]
  46. Lo Mauro, A.; Aliverti, A. Physiology of Respiratory Disturbances in Muscular Dystrophies. Breathe 2016, 12, 318–327. [Google Scholar] [CrossRef]
  47. Gosselin, L.E.; Williams, J.E. Pentoxifylline Fails to Attenuate Fibrosis in Dystrophic (Mdx) Diaphragm Muscle. Muscle Nerve Off. J. Am. Assoc. Electrodiagn. Med. 2006, 33, 820–823. [Google Scholar] [CrossRef]
  48. Krupnick, A.S.; Zhu, J.; Nguyen, T.; Kreisel, D.; Balsara, K.R.; Lankford, E.B.; Clark, C.C.; Levine, S.; Stedman, H.H.; Shrager, J.B. Inspiratory Loading Does Not Accelerate Dystrophy in Mdx Mouse Diaphragm: Implications for Regenerative Therapy. J. Appl. Physiol. 2003, 94, 411–419. [Google Scholar] [CrossRef]
  49. Niebroj-Dobosz, I.; Fidzianska, A.; Glinka, Z. Comparative Studies of Hind Limb and Diaphragm Muscles of Mdx Mice. Basic Appl. Myol. 1997, 7, 381–386. [Google Scholar]
  50. Laws, N.; Hoey, A. Progression of Kyphosis in Mdx Mice. J. Appl. Physiol. 2004, 97, 1970–1977. [Google Scholar] [CrossRef]
  51. Murphy, K.H. Assessment of Respiratory Motor Units in the Mdx Mouse Model of Duchenne Muscular Dystrophy. Master’s Thesis, University College Cork, Cork, Ireland, 2021. [Google Scholar]
  52. O’Halloran, K. Contribution of Extra-Diaphragmatic Inspiratory Muscles to Peak Inspiratory Pressure in Wild-Type and Dystrophic (Mdx) Mice. FASEB J. 2021, 35, 831–848. [Google Scholar] [CrossRef]
  53. Pellegrini, M.; Hedenstierna, G.; Roneus, A.; Segelsjö, M.; Larsson, A.; Perchiazzi, G. The Diaphragm Acts as a Brake during Expiration to Prevent Lung Collapse. Am. J. Respir. Crit. Care Med. 2017, 195, 1608–1616. [Google Scholar] [CrossRef] [PubMed]
  54. Pellegrini, M.; Gudmundsson, M.; Bencze, R.; Segelsjö, M.; Freden, F.; Rylander, C.; Hedenstierna, G.; Larsson, A.S.; Perchiazzi, G. Expiratory Resistances Prevent Expiratory Diaphragm Contraction, Flow Limitation, and Lung Collapse. Am. J. Respir. Crit. Care Med. 2020, 201, 1218–1229. [Google Scholar] [CrossRef] [PubMed]
  55. Muller, N.; Volgyesi, G.; Becker, L.; Bryan, M.H.; Bryan, A.C. Diaphragmatic Muscle Tone. J. Appl. Physiol. 1979, 47, 279–284. [Google Scholar] [CrossRef] [PubMed]
  56. Easton, P.A.; Katagiri, M.; Kieser, T.M.; Platt, R.S. Postinspiratory Activity of Costal and Crural Diaphragm. J. Appl. Physiol. 1999, 87, 582–589. [Google Scholar] [CrossRef]
  57. Roberts, N.W.; Holley-Cuthrell, J.; Gonzalez-Vega, M.; Mull, A.J.; Heydemann, A. Biochemical and Functional Comparisons of Mdx and Sgcg−/− Muscular Dystrophy Mouse Models. BioMed Res. Int. 2015, 2015, e131436. [Google Scholar] [CrossRef]
  58. Giordano, K.; Rodriguez, E.; Green, N.; Armani, M.; Richards, J.; Shaffer, T.H.; Attia, M.W. Pulmonary Function Tests in Emergency Department Pediatric Patients with Acute Wheezing/Asthma Exacerbation. Pulm. Med. 2012, 2012, e724139. [Google Scholar] [CrossRef]
  59. Rahman, T.; Page, R.; Page, C.; Bonnefoy, J.-R.; Cox, T.; Shaffer, T.H. PneuRIPTM: A Novel Respiratory Inductance Plethysmography Monitor. J. Med. Devices 2017, 11, 110101–110106. [Google Scholar] [CrossRef]
  60. DeVanna, J.C.; Kornegay, J.N.; Bogan, D.J.; Bogan, J.R.; Dow, J.L.; Hawkins, E.C. Respiratory Dysfunction in Unsedated Dogs with Golden Retriever Muscular Dystrophy. Neuromuscul. Disord. 2014, 24, 63–73. [Google Scholar] [CrossRef]
  61. Hawkins, E.C.; Bettis, A.K.; Kornegay, J.N. Expiratory Dysfunction in Young Dogs with Golden Retriever Muscular Dystrophy. Neuromuscul. Disord. NMD 2020, 30, 930–937. [Google Scholar] [CrossRef]
  62. Howard, Z.M.; Lowe, J.; Blatnik, A.J.; Roberts, D.; Burghes, A.H.M.; Bansal, S.S.; Rafael-Fortney, J.A. Early Inflammation in Muscular Dystrophy Differs between Limb and Respiratory Muscles and Increases with Dystrophic Severity. Am. J. Pathol. 2021, 191, 730–747. [Google Scholar] [CrossRef]
  63. Leith, D.E. Comparative Mammalian Respiratory Mechanics. Physiologist 1976, 19, 485–510. [Google Scholar]
Figure 1. Setup for optical respiratory dynamics tracking (ORDT). The mouse is placed on a plastic rail with the chest and abdomen facing upwards and the nose exposed to isoflurane gas through a face mask. Four markers are positioned on the fur of the mouse and their movement is recorded by a camera positioned 25 cm away at an angle of 40°. The paper markers are placed on skin/fur at different sites. South marker (S) is trapped on the skin above the sternum. East (E) and west markers (W) are both placed at the location of the 12th rib and north marker (N) is positioned on the area of the abdomen (A). Exemplary marker traces of a wt mouse at 38 days from birth after the pre-processing procedure show that the modulations in N, E and W markers are following the same shape, while the S marker traces a different motion (B).
Figure 1. Setup for optical respiratory dynamics tracking (ORDT). The mouse is placed on a plastic rail with the chest and abdomen facing upwards and the nose exposed to isoflurane gas through a face mask. Four markers are positioned on the fur of the mouse and their movement is recorded by a camera positioned 25 cm away at an angle of 40°. The paper markers are placed on skin/fur at different sites. South marker (S) is trapped on the skin above the sternum. East (E) and west markers (W) are both placed at the location of the 12th rib and north marker (N) is positioned on the area of the abdomen (A). Exemplary marker traces of a wt mouse at 38 days from birth after the pre-processing procedure show that the modulations in N, E and W markers are following the same shape, while the S marker traces a different motion (B).
Cells 11 00918 g001
Figure 2. Exemplary XLF measurement of a wt mouse at 38 days from birth displaying representative images of exhaled and inhaled states as seen in the planar X-ray projection video with right (R) and left lung (L) regions defined (A) and the corresponding calculated relative X-ray transmission traces obtained from right, left, and both lungs averaged (B).
Figure 2. Exemplary XLF measurement of a wt mouse at 38 days from birth displaying representative images of exhaled and inhaled states as seen in the planar X-ray projection video with right (R) and left lung (L) regions defined (A) and the corresponding calculated relative X-ray transmission traces obtained from right, left, and both lungs averaged (B).
Cells 11 00918 g002
Figure 3. Expiration constant (k) derived from ORDT (A) and XLF (B) measurements in mdx and wt mice (n = 5 at 5 weeks, n = 7 onwards) at 1400 ms breathing intervals. ORDT shows a significantly higher k in mdx group compared to wt at all observed time points except week 5. Similarly, XLF derived k is significantly higher in mdx group compared to wt at all observed time points. Both XLF and ORDT did not show a significant difference in k across weeks in each group. Box annotations represent the median and 5–95% intervals. Statistical significance between groups on each measurement determined by Šídák’s multiple comparisons test * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001.
Figure 3. Expiration constant (k) derived from ORDT (A) and XLF (B) measurements in mdx and wt mice (n = 5 at 5 weeks, n = 7 onwards) at 1400 ms breathing intervals. ORDT shows a significantly higher k in mdx group compared to wt at all observed time points except week 5. Similarly, XLF derived k is significantly higher in mdx group compared to wt at all observed time points. Both XLF and ORDT did not show a significant difference in k across weeks in each group. Box annotations represent the median and 5–95% intervals. Statistical significance between groups on each measurement determined by Šídák’s multiple comparisons test * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001.
Cells 11 00918 g003
Figure 4. Longitudinal measurements of fast expiratory phase and area under the curve in mdx and wt mice at 1400 ms breathing intervals. A, B show representative mdx (A) and wt (B) north marker ORDT derived relative displacement traces, as well as definitions of the computed AuC (filled red area) and relative fast expiratory phase amplitude (rmdmax-rmddp). Relative amplitude of the fast expiratory phase (C) is significantly larger in the mdx group compared to wt, in line with this AuC (rmd·(s)) (D) is significantly larger in wt compared to mdx. Box annotations represent the median and 5–95% intervals. Statistical significance between groups determined by Šídák’s multiple comparisons test * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001.
Figure 4. Longitudinal measurements of fast expiratory phase and area under the curve in mdx and wt mice at 1400 ms breathing intervals. A, B show representative mdx (A) and wt (B) north marker ORDT derived relative displacement traces, as well as definitions of the computed AuC (filled red area) and relative fast expiratory phase amplitude (rmdmax-rmddp). Relative amplitude of the fast expiratory phase (C) is significantly larger in the mdx group compared to wt, in line with this AuC (rmd·(s)) (D) is significantly larger in wt compared to mdx. Box annotations represent the median and 5–95% intervals. Statistical significance between groups determined by Šídák’s multiple comparisons test * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001.
Cells 11 00918 g004
Figure 5. Comparison of parameters derived across different recording frequencies with ORDT (100 Hz) and iORDT (60, l77 Hz) at 1400 ms breathing intervals. Visual representation of iORDT setup using 3 additional reference markers positioned on poles around the mouse holder (A). k (B) and AuC (D) change significantly across different recording frequencies while fast expiratory phase-amplitude (C) remains stable.
Figure 5. Comparison of parameters derived across different recording frequencies with ORDT (100 Hz) and iORDT (60, l77 Hz) at 1400 ms breathing intervals. Visual representation of iORDT setup using 3 additional reference markers positioned on poles around the mouse holder (A). k (B) and AuC (D) change significantly across different recording frequencies while fast expiratory phase-amplitude (C) remains stable.
Cells 11 00918 g005
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Svetlove, A.; Albers, J.; Hülsmann, S.; Markus, M.A.; Zschüntzsch, J.; Alves, F.; Dullin, C. Non-Invasive Optical Motion Tracking Allows Monitoring of Respiratory Dynamics in Dystrophin-Deficient Mice. Cells 2022, 11, 918. https://doi.org/10.3390/cells11050918

AMA Style

Svetlove A, Albers J, Hülsmann S, Markus MA, Zschüntzsch J, Alves F, Dullin C. Non-Invasive Optical Motion Tracking Allows Monitoring of Respiratory Dynamics in Dystrophin-Deficient Mice. Cells. 2022; 11(5):918. https://doi.org/10.3390/cells11050918

Chicago/Turabian Style

Svetlove, Angelika, Jonas Albers, Swen Hülsmann, Marietta Andrea Markus, Jana Zschüntzsch, Frauke Alves, and Christian Dullin. 2022. "Non-Invasive Optical Motion Tracking Allows Monitoring of Respiratory Dynamics in Dystrophin-Deficient Mice" Cells 11, no. 5: 918. https://doi.org/10.3390/cells11050918

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop