J Korean Med Sci. 2016 Sep;31(9):1491-1498. English.
Published online May 27, 2016.
© 2016 The Korean Academy of Medical Sciences.
Original Article

A Randomized Controlled Trial of Compression Rates during Cardiopulmonary Resuscitation

Sung Oh Hwang,1 Kyoung-Chul Cha,1 Kyuseok Kim,2 You Hwan Jo,2 Sung Phil Chung,3 Je Sung You,3 Jonghwan Shin,4 Hui Jai Lee,4 Yoo Seok Park,5 Seunghwan Kim,5 Sang-cheon Choi,6 Eun-Jung Park,6 Won Young Kim,7 Dong-Woo Seo,7 Sungwoo Moon,8 Gapsu Han,8 Han Sung Choi,9 Hyunggoo Kang,10 Seung Min Park,11 Woon Yong Kwon,12 and Eunhee Choi13
    • 1Department of Emergency Medicine, Wonju College of Medicine, Yonsei University, Wonju, Korea.
    • 2Department of Emergency Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
    • 3Department of Emergency Medicine, Yonsei University Kangnam Severance Hospital, Seoul, Korea.
    • 4Department of Emergency Medicine, Seoul National University Boramae Hospital, Seoul, Korea.
    • 5Department of Emergency Medicine, Yonsei University Severance Hospital, Seoul, Korea.
    • 6Department of Emergency Medicine, Ajou University Hospital, Suwon, Korea.
    • 7Department of Emergency Medicine, Asan Medical Center, Ulsan University, Seoul, Korea.
    • 8Department of Emergency Medicine, Korea University Ansan Hospital, Ansan, Korea.
    • 9Department of Emergency Medicine, Kyung Hee University Hospital, Seoul, Korea.
    • 10Department of Emergency Medicine, Hanyang University Hospital, Seoul, Korea.
    • 11Department of Emergency Medicine, Hallym University Saint Sacred Hospital, Anyang, Korea.
    • 12Department of Emergency Medicine, Seoul National University Hospital, Seoul, Korea.
    • 13Institute of Lifestyle Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea.
Received February 02, 2016; Accepted May 13, 2016.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

The objective of this study was to compare the efficacy of cardiopulmonary resuscitation (CPR) with 120 compressions per minute (CPM) to CPR with 100 CPM in patients with non-traumatic out-of-hospital cardiac arrest. We randomly assigned patients with non-traumatic out-of-hospital cardiac arrest into two groups upon arrival to the emergency department (ED). The patients received manual CPR either with 100 CPM (CPR-100 group) or 120 CPM (CPR-120 group). The primary outcome measure was sustained restoration of spontaneous circulation (ROSC). The secondary outcome measures were survival discharge from the hospital, one-month survival, and one-month survival with good functional status. Of 470 patients with cardiac arrest, 136 patients in the CPR-100 group and 156 patients in the CPR-120 group were included in the final analysis. A total of 69 patients (50.7%) in the CPR-100 group and 67 patients (42.9%) in the CPR-120 group had ROSC (absolute difference, 7.8% points; 95% confidence interval [CI], -3.7 to 19.2%; P = 0.183). The rates of survival discharge from the hospital, one-month survival, and one-month survival with good functional status were not different between the two groups (16.9% vs. 12.8%, P = 0.325; 12.5% vs. 6.4%, P = 0.073; 5.9% vs. 2.6%, P = 0.154, respectively). We did not find differences in the resuscitation outcomes between those who received CPR with 100 CPM and those with 120 CPM. However, a large trial is warranted, with adequate power to confirm a statistically non-significant trend toward superiority of CPR with 100 CPM.

Trial Registration

Clinical Research Information Service Identifier: KCT0000231

Graphical Abstract

Keywords
Cardiopulmonary Resuscitation; Cardiac Arrest; Basic Life Support

INTRODUCTION

Recent evidence places more importance on chest compressions than ventilation in the resuscitation of victims with sudden cardiac arrest, even though both chest compressions and ventilation are mainstays of cardiopulmonary resuscitation (CPR) (1, 2, 3). Minimizing the interruption of chest compression, delivering high quality chest compressions, and increase in compression fraction are strongly associated with good resuscitation outcome (4, 5, 6). However, several determinants of chest compression to generate optimal hemodynamic effect, such as the optimal depth, rate, and hand placement position, remain unknown. Compression rate is a major determinant of cardiac output during CPR because only 1/3 of the stroke volume during spontaneous circulation is generated by each chest compression (7). Increasing compression rate can be an easy way to improve cardiac output during CPR. However, a very high compression rate might be associated with impaired coronary perfusion and/or decrease in cardiac output by reducing diastolic filling time (8).

During the recent 50 years of CPR history, the recommended chest compression rate has increased from 60 to 100 or at least 100 per minute (9, 10, 11, 12, 13, 14). The 2015 CPR guidelines recommend compression rate between 100 to 120 per minute during CPR without providing a specific compression rate (15). However, the effects of different chest compression rates during CPR on resuscitation outcome in humans have never been prospectively tested. Our primary objective of this study was to compare the efficacy of CPR with 120 compressions per minute (CPM) to CPR with 100 CPM in patients with non-traumatic out-of-hospital cardiac arrest.

MATERIALS AND METHODS

Study design and setting

This study was a multicenter, randomized, parallel-group, investigator-initiated, clinical trial to compare outcomes of cardiac arrest patients receiving CPR with 100 CPM or 120 CPM. A compression rate trial (COMPRATE trial) group was recruited to perform this study, and 12 university hospitals in Korea participated in the study.

Study population and randomization

Consecutive patients with non-traumatic out-of-hospital cardiac arrest admitted to the emergency department (ED) and who were aged 19 years or older were enrolled in the study. Exclusion criteria included cardiac arrest associated with exsanguination, terminal malignancy, aortic dissection, pulmonary thromboembolism, cardiac tamponade, congenital heart disease, or other chronic conditions such as bedridden status. We excluded patients after randomization based on information or patient status that existed before randomization but could not be determined before randomization because of the urgent need for treatment.

Patients were allocated to treatment groups according to the result from the opening of a sealed envelope by the attending emergency physician when the patient with cardiac arrest arrived at the ED. Patients were randomized to CPR with 100 CPM (CPR-100 group) or 120 CPM (CPR-120 group). Immediate caregivers were not blinded due to the nature of the study. However, physicians, neurologists, or healthcare professionals who provided continuous medical care after resuscitation or performed neurologic assessment were unaware of the intervention assignments.

Study protocol

To achieve adequate quality of chest compressions, certified BLS healthcare providers who participated in the study received a 2-hour training course using a manikin, a metronome, and a real-time CPR measurement feedback device (Q-CPR®, Phillips Healthcare, Seattle, WA, USA). CPR was performed according to AHA guidelines (13). The metronome was set at a rate of either 100 or 120 beats/min according to the randomization result. A defibrillator/monitor with a real-time CPR measurement feedback function (HeartStart MRx, Phillips Medical System) was used to maintain and analyze the quality of chest compressions. The optimal depth of chest compression was set to 5.5 cm. The compressor was also guided by a graphic display of compression depth, rate, and chest recoil determined from the monitor in order to maintain the quality of compressions. The compressor was rotated every two minutes.

After successful endotracheal intubation, an end-tidal carbon dioxide (ETCO2) monitoring probe (Microstream®, Phillips Medical System, Seattle, Washington, USA) was connected to the endotracheal tube. Ventilation was administered manually at a rate of 8−10 breaths/min with a volume of approximately one-third of a resuscitation bag (1.5 L) per breath. Defibrillation or administration of medication was performed by discretion of the attending emergency physician, if indicated. ETCO2 measurement was conducted five minutes after the beginning of resuscitation attempts. Peak and average values of ETCO2 were calculated from measurement of the first five consecutive ventilations.

Demographic data including pre-hospital and in-hospital variables were recorded in print and filed into the database. Data was sent twice a month from participating hospitals to the data monitoring committee. Two emergency physicians who were blinded to randomization assignments analyzed data acquired during CPR including the depth and rate of compression using a software package (Heartstart Event Review Pro® 4.1 Hospital Edition, Phillips Medical System, Seattle, Washington, USA).

Measures

The primary outcome measure was sustained restoration of spontaneous circulation (ROSC). Sustained ROSC was defined as a restored spontaneous circulation for longer than 20 consecutive minutes and persisting signs of circulation. The secondary outcome measures were survival and discharge from the hospital, one-month survival, and one-month survival with good functional status, categorized as a score of 2 or less on the cerebral performance category (CPC) (16).

Data analysis

Based on an average ROSC rate of 34% at the participating hospitals during the run-in period, a sample of 182 patients in each group was chosen to detect a 10% increase in the ROSC rate in the CPR-120 group compared to the CPR-100 group for providing a statistical power of 80% with a two-sided alpha value of 0.05, considering that, of all patients included in the study, 10% would be expected to have at least one of the exclusion criteria after enrollment in the study. Finally, a one-year study period was selected in consideration of annual visits of cardiac arrest patients to the participating hospitals. However, this planned sample size could not be obtained during the study period. The investigators decided to terminate the study without further extension of the study period in consideration of various situation of each participating institution.

The principal analyses of the trial were performed on the basis of a modified intention-to-treat basis with data from all randomly assigned patients except those who did not meet the inclusion criteria or those who were excluded. Differences in primary and secondary outcomes between the CPR-100 group and CPR-120 group were compared with χ2 test (Fisher's exact test). Continuous or categorical variables between the two groups were compared with a two-sample t-test or chi-square test (Fisher's exact test) as appropriate. Additional analyses were performed to compare the primary and secondary outcomes in subgroups of each group (Supplementary Tables). The relative predictions for primary outcome were quantified by odds ratio using binary logistic regression, which were presented as a forest plot. A P value less than 0.05 was considered statistically significant, and all statistical analyses were performed using SAS Ver. 9.2 (SAS Inc., NC, USA).

Ethic statement

The study protocol was approved by the institutional review board of Wonju Severance Christian Hospital (IRB No. CR311004) and each participating hospital. The institutional review board at 8 hospitals waived the requirement for written informed consent, while the institutional review board at the remaining 4 hospitals required written consent. At the hospitals where written consent was required, it was obtained after CPR from the next of kin. This trial was registered to Clinical Research Information Service, Korea (www.cris.nih.go.kr) (cris.nih.go.kr number: KCT0000231).

RESULTS

Enrollment and characteristic of the groups

Enrollment of the patients began in November 2011 and finished in December 2012. During the study period, 581 patients with out-of-hospital cardiac arrest presented to the ED of the participating hospitals. Among them, 111 patients (106 patients with traumatic cardiac arrests and 5 patients with death on arrival) were excluded before randomization. A total of 470 patients were randomized into two groups. Of these, 221 patients were assigned to the CPR-100 group, and 249 patients were assigned to the CPR-120 group. A total of 85 patients (38%) from the CPR-100 group and 93 patients (37%) from the CPR-120 group were excluded after randomization based on information or patient status that existed before randomization. Finally, a total of 136 patients (62%) in the CPR-100 group and 156 patients (63%) in the CPR-120 group were included in the analysis (Fig. 1).

Fig. 1
Patient inclusion and groups. DOA, death on arrival; CPR-100, CPR with 100 CPM (compression per minute); CPR-120, CPR with 120 CPM.

Baseline characteristics in terms of the events of cardiac arrest including age, sex, cause, witness of cardiac arrest, bystander CPR rate, initial ECG rhythm at ED, and time from collapse to ED arrival were not different between the two groups. In 81 (60%) patients of in the CPR-100 group and 113 (72%) patients in the CPR-120 group, full-time electronic data recorded during CPR were available for analysis. Compression depth was not different between the two groups (median, 55.7; interquartile range, 51.2–60.7 mm in the CPR-100 group; median, 57.8; interquartile range, 51.1–62.2 mm in the CPR-120 group, P = 0.647). The median compression rate was 101 CPM (interquartile range, 100–104 CPM) in the CPR-100 group and 118 CPM (interquartile range, 114–120 CPM) in the CPR-120 group (P < 0.001). The median chest compression fraction was 96.5% (interquartile range, 94.0%–98.2%) in the CPR-100 group and 95.5% (interquartile range, 93.2%–97.2%) in the CPR-120 group (P = 0.008). Mean ETCO2 was not different between the two groups (CPR-100 group, 25 ± 16 mmHg; CPR-120 group, 27 ± 15 mmHg, P = 0.370) (Table 1).

Table 1
Baseline characteristics of the patients included in the analysis

Comparison of primary and secondary outcomes

There were no statistical differences in primary and secondary outcomes between the two groups. In the comparison of primary outcome, 69 patients (50.7%) in the CPR-100 group and 67 patients (42.9%) in the CPR-120 group had ROSC (absolute difference, 7.8% points; 95% confidence interval [CI], -3.7 to 19.2%; P = 0.183). In the comparison of secondary outcomes, 23 patients (16.9%) in the CPR-100 group and 20 patients (12.8%) in the CPR-120 group were discharged alive from the hospital (absolute difference, 4.1% points; 95% CI, -4.1 to 12.3%, P = 0.325). A total of 17 patients (12.5%) in the CPR-100 group and 10 patients (6.4%) in the CPR-120 group had one-month survival (absolute difference, 6.1% points; 95% CI, -0.6 to 12.9%, P = 0.073). A total of eight patients (5.9%) in the CPR-100 group and four patients (2.6%) in the CPR-120 group had one-month survival with good neurological outcome, categorized as a score of 2 or less on the CPC (absolute difference, 3.3% points; 95% CI, -1.4 to 8.0%, P = 0.154) (Table 2).

Additional analyses

No strong evidence of subgroup differences was observed in primary outcome. However, we found a significant difference in the higher rate of ROSC with CPR-100 in male subgroup (OR, 0.54; 95% CI, 0.31-0.97) (Fig. 2)

Fig. 2
A forest plot of the relative predictions for primary outcome quantified by odds ratio using binary logistic regression.

DISCUSSION

This study is the first randomized clinical trial to test the efficacy of different compression rates in patients with out-of-hospital cardiac arrest. Our study demonstrates that, compared to CPR with 100 CPM, CPR with 120 CPM is not associated with improved resuscitation outcome as measured by the rate of sustained ROSC. We also found that there was no statistical difference between the two groups in secondary outcome measures including survival discharge, one-month survival, or one-month survival with favorable neurological outcome categorized by CPC 1 or 2. There was a statistically non-significant trend toward superiority of CPR with 100 CPM. This results suggest that CPR with 120 CPM has no additional beneficial effect over CPR with 100 CPM on resuscitation outcome measured.

It is unknown whether a specific compression rate during CPR is associated with improved resuscitation outcome in humans. Earlier investigations have suggested that a higher compression rate during CPR results in increased cardiac output. In an animal experiment, CPR with a faster compression rate up to 150 CPM produces a higher cardiac output than CPR with 60 or 100 CPM (17). However, coronary blood flow and cerebral blood flow were not different between CPR with a compression rate of 100 and with a rate of 150 CPM. The results of their study suggest that, with compression rates higher than 100 CPM, no additional increment in coronary or cerebral blood flow is expected, even though cardiac output increases. A small human study reported that, compared to CPR with 60 CPM, aortic pressure and coronary perfusion pressure increased significantly with CPR with 120 CPM (8). It has been demonstrated that compared with 60 CPM, CPR with 120 CPM produced significantly higher mean aortic pressure and coronary perfusion pressure, resulting in improved resuscitation outcome in dogs (18). On the other hand, an animal study reported that blood flow generated by manual chest compression is dependent upon the duration of compression, not the rate, when constant pressure is exerted on the sternum (19). Inconsistent findings from previous studies regarding the hemodynamic efficacy of different compression rates require further human studies in order to determine the optimal compression rate during CPR.

Chest compression rate is known to be associated with resuscitation outcome of cardiac arrest patients. In a prospective, cross-over trial including 23 cardiac arrest patients, CPR with 120 CPM generated higher end-tidal carbon dioxide tension than CPR with 80 CPM (20). However, it is not likely that the difference of 2 mmHg in end-tidal carbon dioxide tension observed in that study would result in different resuscitation outcomes. A prospective, observational study to assess the quality of chest compression reported that mean compression rate was higher in the ROSC group than in the group with no ROSC (90 vs. 79 CPM) when overall chest compression rate was suboptimal (4). Interestingly, the rate of chest compression (98 vs. 107 CPM) was not different between patients with and without ROSC when compression rate was within the optimal range. A retrospective analysis of CPR data revealed that ROSC rates peaked at 125 CPM, and a delivered compression rate less than 75 CPM was associated with a low rate of ROSC (21). However, there was no difference in ROSC rate when compression rates were categorized at < 80, 80-140, and > 140 CPM. A recent systemic review provided separate estimates for the relationship between chest compression rate and outcome. The study result revealed that survivors were significantly more likely to receive chest compression rates closer to the range of 85 to 100 CPM than non-survivors (22). A secondary observational analysis of the data from large multicenter clinical trials reported that the likelihood of survival was greatest in the group who received chest compression rate of 110-119 CPM among five groups based on the compression rate of less than 80, 80-99, 100-119, 120-139, and greater than or equal to 140 CPM with controlling for CPR quality metrics including compression depth (23).

The inconsistency of results from retrospective studies and meta-analysis points to the need for a prospective study to test the effects of different compression rates on resuscitation outcomes. In our study, we compared the resuscitation outcome of two different compression rates with controlling for compression depth with CPR feedback; 100 CPM was chosen as a standard method recommended by various guidelines, and 120 CPM was chosen because it has been reported to produce higher hemodynamic effect in previous reports and is recommended as an upper limit of compression rate by recent European guidelines (14). Results from our study indicate that a compression rate of 120 per minute during CPR is not associated with improvement in resuscitation outcome. Faster compression rates above 120 CPM might cause an adverse effect on coronary perfusion by reducing diastolic perfusion time decreased linearly with compression rate, even though cardiac output and diastolic aortic pressure increase (24). A faster compression rate is associated with rescuer fatigue and low quality of CPR (25). In this context and in light of our study results, 100 CPM is favored as an optimal compression rate during CPR.

Our study has limitations. The current study was underpowered to provide a definitive answer about the difference of ROSC between the two groups. The study did not reach to the number of patients targeted by sample size calculation. Even though the difference in ROSC between the two groups was not found, our results suggest that CPR with 120 CPM is not superior to the current standard CPR with 100 CPM. A larger sample size may find statistically significant difference between the two groups. Randomization and intervention in this study were performed in the ED instead of at initiation of pre-hospital resuscitation. In our emergency medical setting, every patient with out-of-hospital cardiac arrest is transferred to the ED after few minutes of standard CPR with 100 CPM at the scene because pre-hospital termination of resuscitation is not allowed. CPR occurred in the out-of-hospital setting may confound the results related to compression rates. The lack of pre-hospital CPR data and a prolonged time to randomization may be factors that need to be considered when applying our study results to clinical practice. Another concern is that we could not analyze CPR data obtained from all patients enrolled in this study. Full-time recording of CPR data was not available for analysis in 40% of the CPR-100 group and 28% of the CPR-120 group. However, the quality of compressions should have been maintained because the compressor performed CPR with the guidance of a metronome and the graphic display of compression depth and rate from the monitor and the attending physician encouraged them to follow this guidance.

In conclusion, no differences in the resuscitation outcomes were found between those who received CPR with a compression rate of 100/min and those who received CPR with a compression rate of 120/min in patients with out-of-hospital cardiac arrest resuscitated in ED. A large trial is warranted, with adequate power to confirm a statistically non-significant trend toward superiority of CPR with 100 CPM.

Supplementary Material

Table S1

Outcomes of CPR by age

Click here to view.(97K, pdf)

Table S2

Outcomes by sex

Click here to view.(97K, pdf)

Table S3

Outcomes by cardiac arrest etiology

Click here to view.(97K, pdf)

Table S4

Outcomes by witness

Click here to view.(97K, pdf)

Table S5

Outcomes by bystander CPR

Click here to view.(97K, pdf)

Table S6

Outcomes by initial rhythm

Click here to view.(97K, pdf)

Table S7

Outcomes by time from collapse to ED arrival (CTA)

Click here to view.(97K, pdf)

Notes

DISCLOSURE:The authors have no potential conflicts of interest to disclose.

AUTHOR CONTRIBUTION:Conception and design of the study: Hwang SO. Revising draft critically for important intellectual contents: Kim KS, Chung SP. Recruitment of participating centers and management of the data: Cha KC. Acquisition of data: Jo YH, You JS, Shin J, Lee H, Park YS, Kim S, Choi S, Park E, Kim WY, Seo DW, Moon S, Han G, Choi HS, Kang HG, Park SM, Kwon WY. Drafting the article: Hwang SO. Statistical analysis: Choi E. Final approval of the version: Hwang SO. Manuscript approval: all authors.

ACKNOWLEDGMENT

Authors would like to express our appreciation to Phillips Korea (Seoul) for their generous support to our study with provision of their defibrillator/monitors and CPR feedback devices.

References

    1. Bobrow BJ, Spaite DW, Berg RA, Stolz U, Sanders AB, Kern KB, Vadeboncoeur TF, Clark LL, Gallagher JV, Stapczynski JS, et al. Chest compression-only CPR by lay rescuers and survival from out-of-hospital cardiac arrest. JAMA 2010;304:1447–1454.
    1. Iwami T, Kitamura T, Kawamura T, Mitamura H, Nagao K, Takayama M, Seino Y, Tanaka H, Nonogi H, Yonemoto N, et al. Chest compression-only cardiopulmonary resuscitation for out-of-hospital cardiac arrest with public-access defibrillation: a nationwide cohort study. Circulation 2012;126:2844–2851.
    1. Svensson L, Bohm K, Castrèn M, Pettersson H, Engerström L, Herlitz J, Rosenqvist M. Compression-only CPR or standard CPR in out-of-hospital cardiac arrest. N Engl J Med 2010;363:434–442.
    1. Abella BS, Alvarado JP, Myklebust H, Edelson DP, Barry A, O'Hearn N, Vanden Hoek TL, Becker LB. Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest. JAMA 2005;293:305–310.
    1. Abella BS, Sandbo N, Vassilatos P, Alvarado JP, O'Hearn N, Wigder HN, Hoffman P, Tynus K, Vanden Hoek TL, Becker LB. Chest compression rates during cardiopulmonary resuscitation are suboptimal: a prospective study during in-hospital cardiac arrest. Circulation 2005;111:428–434.
    1. Christenson J, Andrusiek D, Everson-Stewart S, Kudenchuk P, Hostler D, Powell J, Callaway CW, Bishop D, Vaillancourt C, Davis D, et al. Chest compression fraction determines survival in patients with out-of-hospital ventricular fibrillation. Circulation 2009;120:1241–1247.
    1. Pernat A, Weil MH, Sun S, Tang W. Stroke volumes and end-tidal carbon dioxide generated by precordial compression during ventricular fibrillation. Crit Care Med 2003;31:1819–1823.
    1. Swenson RD, Weaver WD, Niskanen RA, Martin J, Dahlberg S. Hemodynamics in humans during conventional and experimental methods of cardiopulmonary resuscitation. Circulation 1988;78:630–639.
    1. Guidelines for cardiopulmonary resuscitation and emergency cardiac care. Emergency Cardiac Care Committee and Subcommittees, American Heart Association. Part II. Adult basic life support. JAMA 1992;268:2184–2198.
    1. Cardiopulmonary resuscitation. JAMA 1966;198:372–379.
    1. Kouwenhoven WB, Jude JR, Knickerbocker GG. Closed-chest cardiac massage. JAMA 1960;173:1064–1067.
    1. International Liaison Committee on Resuscitation2005 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Part 2: adult basic life support. Resuscitation 2005;67:187–201.
    1. Sayre MR, Koster RW, Botha M, Cave DM, Cudnik MT, Handley AJ, Hatanaka T, Hazinski MF, Jacobs I, Monsieurs K, et al. Part 5: adult basic life support: 2010 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Circulation 2010;122:S298–324.
    1. Koster RW, Baubin MA, Bossaert LL, Caballero A, Cassan P, Castrén M, Granja C, Handley AJ, Monsieurs KG, Perkins GD, et al. European Resuscitation Council guidelines for resuscitation 2010 section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 2010;81:1277–1292.
    1. Perkins GD, Travers AH, Berg RA, Castren M, Considine J, Escalante R, Gazmuri RJ, Koster RW, Lim SH, Nation KJ, et al. Part 3: adult basic life support and automated external defibrillation: 2015 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Resuscitation 2015;95:e43–69.
    1. Jennett B, Bond M. Assessment of outcome after severe brain damage. Lancet 1975;1:480–484.
    1. Maier GW, Tyson GS Jr, Olsen CO, Kernstein KH, Davis JW, Conn EH, Sabiston DC Jr, Rankin JS. The physiology of external cardiac massage: high-impulse cardiopulmonary resuscitation. Circulation 1984;70:86–101.
    1. Feneley MP, Maier GW, Kern KB, Gaynor JW, Gall SA Jr, Sanders AB, Raessler K, Muhlbaier LH, Rankin JS, Ewy GA. Influence of compression rate on initial success of resuscitation and 24 hour survival after prolonged manual cardiopulmonary resuscitation in dogs. Circulation 1988;77:240–250.
    1. Halperin HR, Tsitlik JE, Guerci AD, Mellits ED, Levin HR, Shi AY, Chandra N, Weisfeldt ML. Determinants of blood flow to vital organs during cardiopulmonary resuscitation in dogs. Circulation 1986;73:539–550.
    1. Kern KB, Sanders AB, Raife J, Milander MM, Otto CW, Ewy GA. A study of chest compression rates during cardiopulmonary resuscitation in humans. The importance of rate-directed chest compressions. Arch Intern Med 1992;152:145–149.
    1. Idris AH, Guffey D, Aufderheide TP, Brown S, Morrison LJ, Nichols P, Powell J, Daya M, Bigham BL, Atkins DL, et al. Relationship between chest compression rates and outcomes from cardiac arrest. Circulation 2012;125:3004–3012.
    1. Wallace SK, Abella BS, Becker LB. Quantifying the effect of cardiopulmonary resuscitation quality on cardiac arrest outcome: a systematic review and meta-analysis. Circ Cardiovasc Qual Outcomes 2013;6:148–156.
    1. Idris AH, Guffey D, Pepe PE, Brown SP, Brooks SC, Callaway CW, Christenson J, Davis DP, Daya MR, Gray R, et al. Chest compression rates and survival following out-of-hospital cardiac arrest. Crit Care Med 2015;43:840–848.
    1. Wolfe JA, Maier GW, Newton JR Jr, Glower DD, Tyson GS Jr, Spratt JA, Rankin JS, Olsen CO. Physiologic determinants of coronary blood flow during external cardiac massage. J Thorac Cardiovasc Surg 1988;95:523–532.
    1. Field RA, Soar J, Davies RP, Akhtar N, Perkins GD. The impact of chest compression rates on quality of chest compressions - a manikin study. Resuscitation 2012;83:360–364.

Metrics
Share
Figures

1 / 2

Tables

1 / 2

PERMALINK