Effects of an implantable two-channel peroneal nerve stimulator versus conventional walking device on spatiotemporal parameters and kinematics of hemiparetic gait

Authors

  • Anke Kottink
  • Martin J. B. Tenniglo
  • Wiebe H. K. de Vries
  • Hermie Hermens
  • Jaap Buurke

DOI:

https://doi.org/10.2340/16501977-0909

Keywords:

stroke, gait, drop foot, peroneal nerve, electrical stimulation.

Abstract

Objective: The aims of this study were: (i) to compare the neuro?prosthetic effect of implantable peroneal nerve stimulation to the orthotic effect of a standard of care intervention (no device, shoe or ankle foot orthosis) on walking, as assessed by spatiotemporal parameters; and (ii) to examine whether there is evidence of an enhanced lower-limb flexion reflex with pe?roneal nerve stimulation and compare the kinematic effect of an implantable peroneal nerve stimulation device vs standard of care intervention on initial loading response of the paretic limb, as assessed by hip, knee and ankle kinematics. Design: Randomized controlled trial. Subjects: A total of 23 chronic stroke survivors with drop foot. Methods: The intervention group received an implantable 2-channel peroneal nerve stimulator for correction of drop foot. The control group continued using a conventional walking device. Spatiotemporal parameters and hip, knee and ankle kinematics were measured while subjects walked with the device on using a 3-dimensional video camera system during baseline and after a follow-up period of 26 weeks. Results: Peroneal nerve stimulation normalized stance and double support of the paretic limb and single support of the non-paretic limb, in comparison with using a conventional walking device. In addition, peroneal nerve stimulation is more effective to provide ankle dorsiflexion during swing and resulted in a normalized initial loading response. Conclusion: Although peroneal nerve stimulation and ankle foot orthosis are both prescribed to correct a drop foot in the same patient population, spatiotemporal parameters, dorsiflexion during swing and loading response are influenced in a functionally different way.

Downloads

Download data is not yet available.

Downloads

Published

2011-11-23

How to Cite

Kottink, A., Tenniglo, M. J. B., de Vries, W. H. K., Hermens, H., & Buurke, J. (2011). Effects of an implantable two-channel peroneal nerve stimulator versus conventional walking device on spatiotemporal parameters and kinematics of hemiparetic gait. Journal of Rehabilitation Medicine, 44(1), 51–57. https://doi.org/10.2340/16501977-0909

Issue

Section

Original Report