Conventional vs. Advanced Echocardiographic Parameters for Predict Fluid Responsiveness in Healthy Dogs

Authors

  • Stephany Buba Lucina Universidade Federal do Paraná https://orcid.org/0000-0002-7685-2942
  • Eloisa Muehlbauer Universidade Federal do Paraná
  • Vinícius Bentivóglio Costa Silva Universidade Federal do Paraná
  • Matheus Folgearini Silveira Universidade Federal do Paraná https://orcid.org/0000-0003-0091-0410
  • Marcela Wolf Universidade Federal do Paraná
  • Julio Pereira dos Santos Universidade Federal do Paraná https://orcid.org/0000-0002-3057-1985
  • Juan Carlos Duque Moreno Universidade Federal do Paraná https://orcid.org/0000-0003-4048-1198
  • Marlos Gonçalves Sousa Universidade Federal do Paraná
  • Tilde Rodrigues Froes Universidade Federal do Paraná

DOI:

https://doi.org/10.22456/1679-9216.121390

Abstract

Background: Volume replacement is considered an essential component in the treatment of critically ill patients, but excess fluid administration can be as harmful as the lack of fluid therapy. Therefore, the volume replacement is only beneficial in patients deemed to be fluid responsive, that is, when the individual has an increase in their stroke volume after administration of a volume challenge. This study aim to assess whether conventional and advanced echocardiographic parameters for assessing left ventricular systolic function are able to predict fluid responsiveness in healthy spontaneously breathing dogs. The hypothesis was that some of these parameters would differ between responsive and non-responsive animals and could be used as a complementary measure for assessment of fluid responsiveness.
Materials, Methods & Results: A prospective study was carried out in which 22 client-owned healthy dogs over 1 year of age that presented to the Veterinary Medical Teaching Hospital for elective neutering procedure were included. All dogs underwent conventional and advanced echocardiographic examination to obtain the left ventricular internal diameter in diastole normalized (LVIDDn), left ventricular internal diameter in systole normalized (LVIDSn), ejection fraction (EF) and shortening fraction (SF) according to the Teischholz methodology, global longitudinal strain (GLS) and tissue motion annular displacement (TMAD). There parameters were evaluated before and after administration of a volume challenge with 10 mL/kg lactate ringer intravenously for 20 min. Based on the variation in aortic velocity integral time, 31.82% of dogs were considered responsive and 68.18% were non-responsive to the volume challenge. For advanced echocardiography, TMAD indexed by body weight (mm/kg) > 0.89 (P = 0.004) and body surface area (mm/m2) >18.9 (P = 0.004) after volume challenge had the best area under the curve values (both 0.895) and smaller gray zone intervals (0.52 - 0.81 and 14.89 - 17.88) for the identification of responsive dogs. Although, TMAD (mm/kg and mm/m2) before volume challenge was also higher in the responsive dogs (P = 0.041 and P = 0.029). As for conventional echocardiography, the LVIDDn < 1.39 (P = 0.003) before volume challenge had the best area under the curve value (0.866) and the smallest gray zone interval (1.4 - 1.57) for the identification of responsive dogs. The GLS and the TMAD in milimeters (mm), percentage (%) and indexed by cubic root of weight (mm/∛kg) did not differ between the responsive and non-responsive dogs before and after volume challenge.
Discussion: TMAD indexed by body weight (mm/kg) and body surface area (mm/m2) before and after volume challenge and the LVIDDn before volume challenge may be useful measures to complement the assessment of fluid responsiveness in spontaneously breathing dogs. This is the first study to use TMAD as a predictive parameter for fluid responsiveness in healthy, spontaneously breathing, dogs. Even it is an advanced echocardiographic technique, TMAD has advantages in
terms of execution time and the fact that it is less dependence on image quality or operator experience. It is possible that in the future such variables may form a useful part of the evaluation of fluid responsiveness in dogs. However, more studies are needed to better understand the applicability of these techniques, especially in dogs with hemodynamic changes.


Keywords: canine, global longitudinal strain, stroke volume, tissue motion annular displacement, TMAD, VTI.

Downloads

Download data is not yet available.

References

Ancierno M.J., Brown S., Coleman A.E., Jepson R.E., Papich M., Stepien R.L. & Syme H.M. 2018. ACVIM consensus statement: guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats. Journal of Veterinary Internal Medicine. 32: 1803-1822.

Blessberger H. & Binder T. 2010. Two dimensional speckle tracking echocardiography: basic principles. Heart. 96: 716-722.

Boon J.A. 2011. Chapter four: evaluation of size, function, and hemodynamics. In: Veterinary Echocardiography. 2nd edn. Ames: WileyBlackwell, pp.266-277.

Bucci M., Rabozzi R., Guglielmini C. & Franci P. 2017. Respiratory variation in aortic blood peak velocity and caudal vena cava diameter can predict fluid responsiveness in anaesthetised and mechanically ventilated dogs. The Veterinary Journal. 277: 30-35.

Cannesson M., Manach Y., Hofer C.K., Goarin J.P., Lehot J.J., Vallet B. & Tavernier B. 2011. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a “gray zone” approach. Anesthesiology. 115(2): 231-341.

Carnabuci C., Hanas S., Ljungvall I., Tidholm A., Haggstrom J. & Hoglund K. 2013. Assessment of cardiac function using global and regional left ventricular endomyocardial and epimyocardial peak systolic strain and strain rate in healthy labrador retriever dogs. Research in Veterinary Sciense. 95(1): 241-248.

Cecconi M., Hofer C., Teboul J.L., Pettila V., Wilkman E., Molnar Z., Rocca G.D., Aldecoa C., Artigas A., Jog S., Sander M., Spies C., Lefrant J.Y. & Backer D. 2015. Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Medicine. 41(9): 1529-1537.

Celeita-Rodríguez N., Teixeira-Neto F.J., Garofalo N.A., Dalmagro T.L., Girotto C.H., Oliveira G.C. & Santos I.F. 2019. Comparison of the diagnostic accuracy of dynamic and static preload indexes to predict fluid responsiveness in mechanically ventilated, isoflurane anesthetized dogs. Veterinary Anaesthesia and Analgesia. 46(3): 276-288.

Chaves R.C.F., Corrêa T.D., Serpa Neto A., Bravim B.A., Cordioli R.L., Moreira F.T., Timenetsky K.T. & Assunção M.S.C. 2018. Assessment of fluid responsiveness in spontaneously breathing patients: a systematic review of literature. Annals of Intensive Care. 8(21): 1-10.

Chetboul V., Sampedrano C.C., Gouni V., Nicolle A.P., Pouchelon J.L. & Tissier R. 2006. Ultrasonographic assessment of regional radial and longitudinal systolic function in healthy awake dogs. Journal of Veterinary Internal Medicine. 20(4): 885-893.

Cornell C.C., Kittleson M.D., Torre P.D., Häggström J., Lombard C.W., Pedersen H.D., Vollmar A. & Wey A. 2004. Allometric scaling of M-mode cardiac measurements in normal adult dogs. Journal of Veterinary Internal Medicine. 18(3): 311-321.

Coudray A., Romand J.A., Treggiari M., Bendjelid K. 2005. Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care. Critical Care Medicine. 33(12): 2757-2762.

Dalen H., Thorstensen A., Romundstad P.R., Aase S.A., Stoylen A. & Vatten L.J. 2011. Cardiovascular risk factors and systolic and diastolic cardiac function: a tissue Doppler and speckle tracking echocardiographic study. Journal of the American Society of Echocardiography. 24(3): 322-332.

Grue J.F., Storve S., Dalen H., Salvesen O., Mjolstad O.C., Samstad S.O., Torp H. & Haugen B.O. 2017. Automatic measurements of mitral annular plane systolic excursion and velocities to detect left ventricular dysfunction. Ultrasound in Medicine and Biology. 12(1): 924-930.

Heenen S., Backer D. & Vincent J.L. 2006. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Critical Care. 10 (4): 1-7.

Jones C.J.H., Raposo L. & Gibson D.G. 1990. Functional importance of the long axis dynamics of the human left ventricle. British Heart Journal. 63(4): 215-220.

Kusunose K., Zhang Y., Mazgalev T.N., Thomas J.D. & Popovic Z.B. 2013. Left ventricular strain distribution in healthy dogs and in dogs with tachycardia-induced dilated cardiomyopathy. Cardiovascular Ultrasound. 11: 1-11.

Lamia B., Ochagavia A., Monnet X., Chemla D., Richard C. & Teboul J.L. 2007. Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Medicine. 33: 1125-1132.

Lammi M.R., Aiello B., Burg G.T., Rehman T., Douglas I.S., Wheeler A.P. & Boisblanc B.P. 2015. Response to fluid boluses in the fluid and catheter treatment trial. Chest. 148(4): 919-926.

Locatelli C., Spalla I., Zanaboni A.M., Brambilla P.G. & Bussadori C. 2016. Assessment of right ventricular function by feature-tracking echocardiography in conscious healthy dogs. The Research Veterinary Sciense. 105: 103-110.

Marik P.E. & Lemson J. 2014. Fluid responsiveness: an evolution of our understanding. British Journal of Anaesthesia. 112(4): 617-620.

Michard F. 2002. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 121(6): 2000-2008.

Miller A. & Mandeville J. 2016. Predicting and measuring fluid responsiveness with echocardiography. Echocardiography Research and Practice. 3(2): 1-12.

Monnet X., Marik P.E. & Teboul J.L. 2016. Prediction of fluid responsiveness: an update. Annals of Intensive Care. 6: 1-11.

Oricco S., Rabozzi R., Meneghini C. & Franci P. 2019. Usefulness of focused cardiac ultrasonography for predicting fluid responsiveness in conscious, spontaneously breathing dogs. American Journal of Veterinary Research. 80(4): 369-377.

Thavendiranathan P., Poulin F., Lim K.D., Plana J.C., Woo A. & Marwick T.H. 2014. Use of myocardial strain imaging by echocardiography for the early detection of cardiotoxicity in patients during and after cancer chemotherapy. Journal of American College Cardiology. 63(25): 2751-2768.

Thomas W.P., Gaber C.E., Jacobs G.J., Kaplan P.M., Lombard C.W., Moise N.S. & Moses B.L. 1993. Recommendations for standards in transthoracic two-dimensional echocardiography in the dog and cat. Echocardiography Committee of the Specialty of Cardiology, American College of Veterinary Internal Medicine. Journal of Veterinary Internal Medicine. 7(4): 247-252.

Thorstensen A., Dalen H., Amundsen B.H. & Stoylen A. 2011. Peak systolic velocity indices are more sensitive than end-systolic indices in detecting contraction changes assessed by echocardiography in young healthy humans. European Journal of Echocardiography. 12(12): 924-930.

Westrup U. & McEvoy F.J. 2013. Speckle tracking echocardiography in mature Irish Wolfhound dogs: technical feasibility, measurement error and reference intervals. Acta Veterinaria Scandinavica. 55(41): 1-11.

Wolf M., Lucina S.B., Bruler B.C., Tuleski G.L.R., Silva V.B.C. & Sousa M.G. 2018. Assessment of longitudinal systolic function using tissue motion annular displacement in healthy dogs. Journal of Veterinary Cardiology. 20(3): 175-185.

Published

2022-03-20

How to Cite

Buba Lucina, S., Muehlbauer, E., Bentivóglio Costa Silva, V., Folgearini Silveira, M., Wolf, M., Pereira dos Santos, J., Duque Moreno, J. C., Gonçalves Sousa, M., & Rodrigues Froes, T. (2022). Conventional vs. Advanced Echocardiographic Parameters for Predict Fluid Responsiveness in Healthy Dogs . Acta Scientiae Veterinariae, 50. https://doi.org/10.22456/1679-9216.121390

Issue

Section

Articles

Most read articles by the same author(s)