Barbosa, J. R., Melo, C., Hermes, C. J. L., and Waltrich, P. J. (2009). A study of the air-side heat transfer and pressure drop characteristics of tube-fin “no-frost” evaporators. Applied Energy, 86(9): 1484–1491. https://doi.org/10.1016/j.apenergy.2008.11.027
Bejan, A., and Tsatsaronis, G. (1996). Thermal design and optimization. John Wiley & Sons.
Bell, I. H., and Groll, E. A. (2011). Air-side particulate fouling of microchannel heat exchangers: Experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger. Applied Thermal Engineering, 31(5): 742–749.
Cuce, P. M., and Cuce, E. (2017). Toward cost-effective and energy-efficient heat recovery systems in buildings: Thermal performance monitoring. Energy, 137: 487–494.
Cuce, P. M., Cuce, E., and Riffat, S. (2016). A novel roof type heat recovery panel for low-carbon buildings: An experimental investigation. Energy and Buildings, 113: 133–138. https://doi.org/10.1016/j.enbuild.2015.12.024
Diao, Y. H., Liang, L., Kang, Y. M., Zhao, Y. H., Wang, Z. Y., and Zhu, T. T. (2017). Experimental study on the heat recovery characteristic of a heat exchanger based on a flat micro-heat pipe array for the ventilation of residential buildings. Energy and Buildings, 152: 448–457.
Gnielinski, V. (1976). New equations for heat and mass transfer in turbulent pipe and channel flow. Int. Chem. Eng., 16(2): 359–368.
Jeong, J.-W., and Mumma, S. (2003). Energy conservation benefits of a dedicated outdoor air system with parallel sensible cooling by ceiling radiant panels. ASHRAE Transactions, 109(2): 627–636.
Li, X. Y., Li, Z. H., and Tao, W. Q. (2018). Experimental study on heat transfer and pressure drop characteristics of fin-and-tube surface with four convex-strips around each tube. International Journal of Heat and Mass Transfer, 116: 1085–1095.
Liang, C. H., Zhang, L. Z., and Pei, L. X. (2010). Performance analysis of a direct expansion air dehumidification system combined with membrane-based total heat recovery. Energy, 35(9): 3891–3901. https://doi.org/10.1016/j.energy.2010.06.002
Manz, H., and Huber, H. (2000). Experimental and numerical study of a duct r heat exchanger unit for building ventilation, 189–196.
McQuiston, F. C., and Parker, J. D. (1982). Heating, ventilating, and air conditioning: analysis and design.
Naphon, P. (2010). On the performance of air conditioner with heat pipe for cooling air in the condenser. Energy Conversion and Management, 51(11): 2362–2366.
Pérez-Lombard, L., Ortiz, J., and Pout, C. (2008). A review on buildings energy consumption information. Energy and Buildings, 40(3), 394–398. https://doi.org/10.1016/j.enbuild.2007.03.007
Ramadan, M., El Rab, M. G., and Khaled, M. (2015). Parametric analysis of air-water heat recovery concept applied to HVAC systems: Effect of mass flow rates. Case Studies in Thermal Engineering, 6: 61–68. https://doi.org/10.1016/j.csite.2015.06.001
Roulet, C. A., Heidt, F. D., Foradini, F., and Pibiri, M. C. (2001). Real heat recovery with air handling units. Energy and Buildings, 33(5): 495–502. https://doi.org/10.1016/S0378-7788(00)00104-3
Schmidt, T. E. (1949). Heat transfer calculations for extended surfaces. Refrig. Eng, 57(4): 351–357.
Vakiloroaya, V., Samali, B., Cuthbert, S., Pishghadam, K., and Eager, D. (2014a). Thermo-economic optimization of condenser coil configuration for HVAC performance enhancement. Energy and Buildings, 84: 1–12. https://doi.org/10.1016/j.enbuild.2014.07.079
Vakiloroaya, V., Samali, B., Fakhar, A., and Pishghadam, K. (2014b). Thermo-economic optimization of rooftop unit’s evaporator coil for energy efficiency and thermal comfort. Building Simulation, 7(4): 345–359. https://doi.org/10.1007/s12273-013-0151-6
Wang, C.-C., and Chi, K.-Y. (2000). Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part I: new experimental data. International Journal of Heat and Mass Transfer, 43(15): 2681–2691. https://doi.org/10.1016/S0017-9310(99)00332-4
Wang, C.-C., Chi, K.-Y., and Chang, C.-J. (2000). Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part I: new experimental data. International Journal of Heat and Mass Transfer, 43(August 2000), 2693–2700. https://doi.org/10.1016/S0017-9310(99)00333-6
Warden, B. D. (2004). Supply Air CO 2 Control. ASHRAE Journal, 46(October).
Yau, Y. H. (2008). The use of a double heat pipe heat exchanger system for reducing energy consumption of treating ventilation air in an operating theatre-A full year energy consumption model simulation. Energy and Buildings, 40(5), 917–925. https://doi.org/10.1016/j.enbuild.2007.07.006
Zhang, Z.-Y., Zhang, C.-L., Ge, M.-C., and Yu, Y. (2018). A frost-free dedicated outdoor air system with exhaust air heat recovery. Applied Thermal Engineering, 128: 1041–1050.