[1] Buckle, IG. and Mayes, RL. (1990). Seismic isolation: history, application and performance- A world overview. Earthquake Spectra, 6(2), 161-202.
[2] Nagarajaiah, S. and Reinhorn, AM. and Constantinou, MC. (1991). Nonlinear dynamic analysis of 3-D base isolated structures. Structural Engineering, ASCE, Vol. 117,No. 7, July.
[3] Shin, TM. And Kim, KJ. (1997). Seismic response of submerged secondary systems on base-isolated structures. Engineering Structures, Elsevier Science Ltd, Vol. 19, No. 6, pp. 452 464.
[4] Moroni, MO. and Sarrazin, M. and Boroschek, R. (1998). Experiments on base-isolated building in santiago. Engineering Structures, Elsevier Science Ltd, Vol. 20, No. g, pp. 720 725.
[5] Jangid, RS. (2000). Optimum frictional elements in sliding isolation systems. Computers and Structures, Elsevier Science Ltd, 76, 651-661.
[6] Hong, WK. and Kim, HC. (2004). Performance of a Multi-Story Structure With a Resilient-Friction Base Isolation System. Computers and Structures, Elsevier Science Ltd, 82, 2271-2283.
[7] Kaplan, H. and Aydilek, HA. (2006). Seismic analysis of a low-rise base-isolated structural system. Low Frequency Noise, Vibration and Active Control, 25(2), 93-109.
[8] Khoshnoudian, F. and Azizi, N. (2007). Nonlinear response of a torsionally coupled base- isolated structure. Structures & Buildings, 160 Issue SB4, 207-219.
[9] Jangid, RS. (2007). Optimum lead-rubber isolation bearings for near-fault motions. Engineering Structures, Elsevier Science Ltd, 29, 2503-2513.
[10] Matsagar, VA. and Jangid, RS. (2008). Base isolation for seismic retrofitting of structures. Practice Periodical on Structural Design and Construction, Vol. 13, No. 4.
[11] Shao, J. and Liu, J. and Zhao, J. (2012). Evaluation of various non-linear 3-D models for predicting wind flow around an isolated high-rise building within the surface boundary layer. Building and Environment, Elsevier Science Ltd, 57, 145-155.
[12] Wang, SJ. and Chang, KC. and Hwang, JS. and Hsiao, JY. and Lee, BH. and Hung, YC. (2012). Dynamic behavior of a building structure tested with base and mid-story isolation systems. Engineering Structures, Elsevier Science Ltd, 42, 420-433.
[13] Iuliis, MD. and Fealla, C. (2013). Effectiveness analysis of a semiactive base isolation strategy using information from an early-warning network. Engineering Structures Elsevier Science Ltd, 52, 518-535.
[14] Ma, CF. and Zhang, YH. and Tan, P. and Kennedy, D. and Williams, FW. and Zhou, FL. (2013). Non-stationary seismic response analysis of base-isolated buildings with many hysteretic devices. Computers and Structures, Elsevier Science Ltd, 123, 39-47.
[15] Khoshnoudian, F. and Esrafili, S. (2013). Lateral force distribution on base-isolated structures under near-field earthquakes. Structures and Buildings, 166, 342-354.
[16] Jensen, HA. and Kusanovic, DS. (2014). On the effect of near-field excitations on the reliability-based performance and design of base-isolated structures. Probabilistic Engineering Mechanics, Elsevier Science Ltd, 36, 28-44.
[17] Das, S. Gur, S. Mishra, SK. Chakraborty, S. (2015). Optimal performance of base isolated building considering limitation on excessive isolator displacement. Structure and Infrastructure Engineering, Taylor & Francis, Vol. 11, No. 7, 904-917.
18 ] آییننامه طراحی ساختمانها در برابر زلزله استاندارد 2800 ویرایش چهارم ( 1393 ). مرکز تحقیقات ساختمان و مسکن. ]
19 ] مقررات ملیّ ساختمان ایران، مبحث ششم، بارهای وارد بر ساختمان، ویرایش سوم، ( 1392 )، دفتر تدوین مقررات ملیّ ساختمان ایران. ]
20 ] مقررات ملّی ساختمان ایران، مبحث دهم، طرح و اجرای ساختمانهای فولادی، ویرایش چهارم، ( 1392 )، دفتر تدوین مقررات ملیّ ]
ساختمان ایران.
1389 ، معاونت امور فنی سازمان مدیریت و ، 21 ] راهنمای طراحی و اجرای سیستمهای جداساز لرزهای در ساختمانها، نشریه شماره 523 ]
برنامهریزی.
1385 ، معاونت امور فنی سازمان مدیریت و برنامهریزی. ، 22 ] دستورالعمل بهسازی لرزهای ساختمانهای موجود، نشریه شماره 360 ]
92