Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original articles
Effect of mandibular bilateral distal extension denture design on masticatory performance
Tasuku YoshimotoYoko HasegawaMa Therese Sta MariaPinta MaritoSimonne SalazarKazuhiro HoriTakahiro Ono
Author information
JOURNAL OPEN ACCESS

2023 Volume 67 Issue 4 Pages 539-547

Details
Abstract

Purpose: Removable partial dentures have a wide range of applications as missing tooth prostheses, and the denture design can be quite diverse. However, the factors affecting masticatory function remain unclear. We investigated the effect of denture design, especially the use of indirect retainers and major connectors, on masticatory function in patients with mandibular bilateral distal extension dentures.

Methods: Fifty-three patients with mandibular Kennedy Class I and Eichner classification B occlusal support were included in this study. Masticatory performance (MP) was assessed using gummy jelly. For the dentures, the type of major connector (bar or apron), presence or absence of indirect retainers, number of rests, and number of artificial teeth were evaluated. The number of functional teeth and occlusal support, Eichner classification, maxillary denture usage, mandibular residual ridge height, and duration of denture use were also evaluated. The factors influencing on the MP were evaluated using the Mann-Whitney U test, Spearman’s correlation coefficient, and logistic regression analysis.

Results: MP was significantly higher when the major connector was bar-type or when there was an indirect retainer than with an apron-type or no indirect retainer. MP was positively correlated with the number of functional teeth, occlusal support, and number of rests. Logistic regression analysis revealed that the number of functional teeth and the presence or absence of an indirect retainer were factors that significantly influenced the MP.

Conclusions: An indirect retainer setting is useful for achieving good masticatory performance in mandibular bilateral distal extension dentures.

Content from these authors
© 2023 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/