skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Aging and service wear of air-operated valves used in safety-related systems at nuclear power plants

Technical Report ·
DOI:https://doi.org/10.2172/94555· OSTI ID:94555

Air-operated valves (AOVs) are used in a variety of safety-related applications at nuclear power plants. They are often used where rapid stroke times are required or precise control of the valve obturator is required. They can be designed to operate automatically upon loss of power, which is often desirable when selecting components for response to design basis conditions. The purpose of this report is to examine the reported failures of AOVs and determine whether there are identifiable trends in the failures related to predictable causes. This report examines the specific components that comprise a typical AOV, how those components fail, when they fail, and how such failures are discovered. It also examines whether current testing frequencies and methods are effective in predicting such failures.

Research Organization:
US Nuclear Regulatory Commission (NRC), Washington, DC (United States). Div. of Engineering Technology; Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
Nuclear Regulatory Commission, Washington, DC (United States)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
94555
Report Number(s):
NUREG/CR-6016; ORNL-6748; ON: TI95012813; TRN: 95:018438
Resource Relation:
Other Information: PBD: May 1995
Country of Publication:
United States
Language:
English