Ashcroft Pressure Switch Monitor for Low SCHe Purge Pressure
These 0-15 psig pressure switches are located in the SCHe helium purge lines after PCV-5*23 and before PCV-5*27. The pressure switches monitor the pressure being maintained between the two PCVs and actuate on low pressure of 15 psig. This design is used for each of the SCHe supply lines (4). Electronic output signal is NON-SAFETY (GS).
- Research Organization:
- Fluor Hanford, Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Management (EM) (US)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 803959
- Report Number(s):
- SNF-3928, Rev.2; ECN-661400; TRN: US0300810
- Resource Relation:
- Other Information: PBD: 21 Jun 2000
- Country of Publication:
- United States
- Language:
- English
Similar Records
Ashcroft Pressure Switch Monitor for Low SCHe Purge Pressure
Ashcroft Pressure Switch Monitor for Low SCHe Supply Bottle Pressure
Aschroft Pressure Switch Monitor for Low SCHe Supply Bottle Pressure
Technical Report
·
Sun Sep 03 00:00:00 EDT 2000
·
OSTI ID:803959
Ashcroft Pressure Switch Monitor for Low SCHe Supply Bottle Pressure
Technical Report
·
Wed Jun 21 00:00:00 EDT 2000
·
OSTI ID:803959
Aschroft Pressure Switch Monitor for Low SCHe Supply Bottle Pressure
Technical Report
·
Sun Sep 03 00:00:00 EDT 2000
·
OSTI ID:803959