Title: A Technique to Determine Billet Core Charge Weight for P/M Fuel Tubes

Technical Report ·
DOI:https://doi.org/10.2172/782825· OSTI ID:782825

The core length in an extruded tube depends on the weight of powder in the billet core. In the past, the amount of aluminum powder needed to give a specified core length was determined empirically. This report gives a technique for calculating the weight of aluminum powder for the P/M core. An equation has been derived which can be used to determine the amount of aluminum needed for P/M billet core charge weights. Good agreement was obtained when compared to Mark 22 tube extrusion data. From the calculated charge weight, the elastomeric bag can be designed and made to compact the U3O8-Al core.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC09-76SR00001
OSTI ID:
782825
Report Number(s):
DPST-84-516; TRN: US0103506
Resource Relation:
Other Information: PBD: 2 Jul 2001
Country of Publication:
United States
Language:
English