Title: In vivo measurement of actinides in the human lung. [Calibration and comparison of Phoswich, large-area proportional counter, and intrinsic germanium planar array detector systems]

Abstract

The problems associated with the in vivo detection and measurement of actinides in the human lung are discussed together with various measurement systems currently in use. In particular, the methods and calibration procedures employed at the Lawrence Livermore Laboratory, namely, the use of twin Phoswich detectors and a new, more realistic, tissue-equivalent phantom, are described. Methods for the measurement of chest-wall thickness, fat content, and normal human background counts are also discussed. Detection-efficiency values and minimum detectable activity estimates are given for three common actinides, /sup 238/Pu, /sup 239/Pu, and /sup 241/Am.

Authors:
; ;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
OSTI Identifier:
5730163
Report Number(s):
UCRL-83548
TRN: 80-001361
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.; 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; AMERICIUM 241; RADIATION MONITORING; LUNGS; RADIOACTIVITY; PLUTONIUM 238; PLUTONIUM 239; RADIATION DETECTORS; CALIBRATION; PERFORMANCE TESTING; ADIPOSE TISSUE; CHEST; COMPARATIVE EVALUATIONS; EXPERIMENTAL DATA; IN VIVO; ISOLATED VALUES; MAN; MEASURING METHODS; PHANTOMS; THICKNESS; ULTRASONOGRAPHY; ACTINIDE ISOTOPES; ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; AMERICIUM ISOTOPES; ANIMALS; BODY; BODY AREAS; CONNECTIVE TISSUE; DATA; DATA FORMS; DIAGNOSTIC TECHNIQUES; DIMENSIONS; EVEN-EVEN NUCLEI; EVEN-ODD NUCLEI; HEAVY NUCLEI; INFORMATION; ISOTOPES; MAMMALS; MEASURING INSTRUMENTS; MOCKUP; MONITORING; NUCLEI; NUMERICAL DATA; ODD-EVEN NUCLEI; ORGANS; PLUTONIUM ISOTOPES; PRIMATES; RADIOISOTOPES; RESPIRATORY SYSTEM; STRUCTURAL MODELS; TESTING; TISSUES; VERTEBRATES; YEARS LIVING RADIOISOTOPES; 560171* - Radiation Effects- Nuclide Kinetics & Toxicology- Man- (-1987); 440101 - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments

Citation Formats

Anderson, A L, Campbell, G W, and Griffith, R V. In vivo measurement of actinides in the human lung. [Calibration and comparison of Phoswich, large-area proportional counter, and intrinsic germanium planar array detector systems]. United States: N. p., 1979. Web. doi:10.2172/5730163.
Anderson, A L, Campbell, G W, & Griffith, R V. In vivo measurement of actinides in the human lung. [Calibration and comparison of Phoswich, large-area proportional counter, and intrinsic germanium planar array detector systems]. United States. https://doi.org/10.2172/5730163
Anderson, A L, Campbell, G W, and Griffith, R V. 1979. "In vivo measurement of actinides in the human lung. [Calibration and comparison of Phoswich, large-area proportional counter, and intrinsic germanium planar array detector systems]". United States. https://doi.org/10.2172/5730163. https://www.osti.gov/servlets/purl/5730163.
@article{osti_5730163,
title = {In vivo measurement of actinides in the human lung. [Calibration and comparison of Phoswich, large-area proportional counter, and intrinsic germanium planar array detector systems]},
author = {Anderson, A L and Campbell, G W and Griffith, R V},
abstractNote = {The problems associated with the in vivo detection and measurement of actinides in the human lung are discussed together with various measurement systems currently in use. In particular, the methods and calibration procedures employed at the Lawrence Livermore Laboratory, namely, the use of twin Phoswich detectors and a new, more realistic, tissue-equivalent phantom, are described. Methods for the measurement of chest-wall thickness, fat content, and normal human background counts are also discussed. Detection-efficiency values and minimum detectable activity estimates are given for three common actinides, /sup 238/Pu, /sup 239/Pu, and /sup 241/Am.},
doi = {10.2172/5730163},
url = {https://www.osti.gov/biblio/5730163}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Nov 06 00:00:00 EST 1979},
month = {Tue Nov 06 00:00:00 EST 1979}
}