In a fluidized-bed combustor, a bed of combustible (coal) and noncombustible material is fluidized using air blown upward. Using dolomite or limestone as the noncombustible material, it is possible to have fuel combustion and flue gas desulfurization taking place simultaneously in the combustion vessel. If operation occurs under atmospheric pressure, the average partial pressure of carbon dioxide in the combustor (typically, 10-15% of the total pressure) is considerably lower than the equilibrium CO, pressure for decomposition of limestone (CaCO{sub 3})or dolomite (CaCO{sub 3}{circ}MgCO{sub 3}) at the temperatures usually encountered in FBC units (800-950 {degrees}C). In the high temperature environment of the AFBC unit, the limestone or dolomite particles undergo calcination, yielding a highly porous product (CaO or MgO), which reacts with the sulfur dioxide produced during coal combustion forming, mainly, calcium or magnesium sulfate. The sulfates occupy more space than the oxides they replace, and as a result, the pores of the calcine are completely plugged with solid product before complete conversion takes place. (The conversion for complete with pore plugging is about 50% for the calcine of a stone consisting of CaCO{sub 3} only.) Pores of different size are plugged at different conversion levels, and it is thus possible to have formation of inaccessible pore space in the interior of the particles when the small feeder pores of clusters of large pore are filled with solid product. Moreover, under conditions of strong internal diffusional limitations, complete pore closure may first take place at the external surface of the particles while there is still open pore space left in the interior. For these reasons, ultimate conversions much lower than those predicted by the stoichiometry of the reaction for complete plugging of the internal pore space (less than 30-40%) are seen in AFBC units.

Research Organization:
Rochester Univ., NY (United States). Dept. of Chemical Engineering
Sponsoring Organization:
USDOE Assistant Secretary for Fossil Energy, Washington, DC (United States)
DOE Contract Number:
FG22-95PC95217
OSTI ID:
415351
Report Number(s):
DOE/PC/95217-T1; ON: DE97050226; TRN: 97:000126
Resource Relation:
Other Information: PBD: Feb 1996
Country of Publication:
United States
Language:
English