Decontamination and dismantlement of the old hot laundry, CFA-669. Final report
Abstract
This final report describes the decontamination and dismantlement (D&D) of the old hot laundry, located at the Idaho National Engineering Laboratory (INEL) Central Facilities Area (CFA). The report describes the site before and after D&D, processes used, cost and duration, and waste volume generated. In addition, lessons learned are presented. Pre-D&D characterization indicated gross alpha concentrations in the building ranged from 6 to 310 pCi/g and gross beta measurements from 6 to 15,000 pCi/g. Gamma spectrum analysis identified cobalt-60, cesium-137, antimony-125, europium-152, europium-154, and niobium-94.
- Authors:
- Publication Date:
- Research Org.:
- Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)
- Sponsoring Org.:
- USDOE, Washington, DC (United States)
- OSTI Identifier:
- 33080
- Report Number(s):
- INEL-94/0139
ON: DE95008672; TRN: 95:008984
- DOE Contract Number:
- AC07-94ID13223
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: Jan 1995
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 05 NUCLEAR FUELS; IDAHO NATIONAL ENGINEERING LABORATORY; LAUNDRIES; DECONTAMINATION; DECOMMISSIONING; PROGRESS REPORT; MERCURY; ASBESTOS; RADIOACTIVE WASTES
Citation Formats
Smith, D L, and Perry, E F. Decontamination and dismantlement of the old hot laundry, CFA-669. Final report. United States: N. p., 1995.
Web. doi:10.2172/33080.
Smith, D L, & Perry, E F. Decontamination and dismantlement of the old hot laundry, CFA-669. Final report. United States. https://doi.org/10.2172/33080
Smith, D L, and Perry, E F. 1995.
"Decontamination and dismantlement of the old hot laundry, CFA-669. Final report". United States. https://doi.org/10.2172/33080. https://www.osti.gov/servlets/purl/33080.
@article{osti_33080,
title = {Decontamination and dismantlement of the old hot laundry, CFA-669. Final report},
author = {Smith, D L and Perry, E F},
abstractNote = {This final report describes the decontamination and dismantlement (D&D) of the old hot laundry, located at the Idaho National Engineering Laboratory (INEL) Central Facilities Area (CFA). The report describes the site before and after D&D, processes used, cost and duration, and waste volume generated. In addition, lessons learned are presented. Pre-D&D characterization indicated gross alpha concentrations in the building ranged from 6 to 310 pCi/g and gross beta measurements from 6 to 15,000 pCi/g. Gamma spectrum analysis identified cobalt-60, cesium-137, antimony-125, europium-152, europium-154, and niobium-94.},
doi = {10.2172/33080},
url = {https://www.osti.gov/biblio/33080},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Jan 01 00:00:00 EST 1995},
month = {Sun Jan 01 00:00:00 EST 1995}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.