Title: Recommended ALIs and DACs for 10 CFR part 220: A consistent numerical set

Abstract

Appendix B to 10 CFR Part 20 contains numerical data for controlling the intake of radionuclides in the workplace or in the environment. These data, derived from the recommendations of the International Commission on Radiological Protection (ICRP), do not provide a numerically consistent basis for demonstrating compliance with the limitation on dose stated in the regulation. This situation is largely a consequence of the numerical procedures used by the ICRP which did not maintain, in a strict numerical sense, the hierarchial relationship among the radiation protection quantities. In this work recommended values of the quantities in Appendix B to CFR Part 20 are developed using the dose coefficients of the applicable ICRP publications and a numerical procedure which ensures that the tabulated quantities are numerically consistent.

Authors:
Publication Date:
Research Org.:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Org.:
Nuclear Regulatory Commission, Washington, DC (United States)
OSTI Identifier:
278394
Report Number(s):
ORNL/TM-13188
ON: DE96014270; TRN: 96:020943
DOE Contract Number:  
AC05-96OR22464
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 1 May 1996
Country of Publication:
United States
Language:
English
Subject:
56 BIOLOGY AND MEDICINE, APPLIED STUDIES; DOSE LIMITS; RECOMMENDATIONS; INTAKE; RADIATION PROTECTION; ICRP; DOSE EQUIVALENTS; CALCULATION METHODS; INHALATION; INGESTION; SAFETY STANDARDS

Citation Formats

Eckerman, K F. Recommended ALIs and DACs for 10 CFR part 220: A consistent numerical set. United States: N. p., 1996. Web. doi:10.2172/278394.
Eckerman, K F. Recommended ALIs and DACs for 10 CFR part 220: A consistent numerical set. United States. https://doi.org/10.2172/278394
Eckerman, K F. 1996. "Recommended ALIs and DACs for 10 CFR part 220: A consistent numerical set". United States. https://doi.org/10.2172/278394. https://www.osti.gov/servlets/purl/278394.
@article{osti_278394,
title = {Recommended ALIs and DACs for 10 CFR part 220: A consistent numerical set},
author = {Eckerman, K F},
abstractNote = {Appendix B to 10 CFR Part 20 contains numerical data for controlling the intake of radionuclides in the workplace or in the environment. These data, derived from the recommendations of the International Commission on Radiological Protection (ICRP), do not provide a numerically consistent basis for demonstrating compliance with the limitation on dose stated in the regulation. This situation is largely a consequence of the numerical procedures used by the ICRP which did not maintain, in a strict numerical sense, the hierarchial relationship among the radiation protection quantities. In this work recommended values of the quantities in Appendix B to CFR Part 20 are developed using the dose coefficients of the applicable ICRP publications and a numerical procedure which ensures that the tabulated quantities are numerically consistent.},
doi = {10.2172/278394},
url = {https://www.osti.gov/biblio/278394}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed May 01 00:00:00 EDT 1996},