skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: ANALYTICAL RESULTS OF MOX COLEMANITE CONCRETE SAMPLE POURED MAY 4, 2012

Technical Report ·
DOI:https://doi.org/10.2172/1043261· OSTI ID:1043261

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use Colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Sample 04 May 12/Test/S1-1, S1-2, and S1-3 was received on 5/9/2012 and analyzed. The total density measure by the ASTM method C 642 was 2.00 g/cm{sup 3}, within the lower bound of 1.88 g/cm{sup 3}. The partial hydrogen density of 6.35E-02 g/cm{sup 3} as measured using method ASTM E 1311 met the lower bound of 6.04E-02 g/cm{sup 3}. The measured partial boron density of 1.88E-01 g/cm{sup 3} exceeded the lower bound of 1.65E-01 g/cm{sup 3} when the sodium peroxide fusion dissolution method was used in place of the prescribed ASTM C 1301 method.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
DE-AC09-08SR22470
OSTI ID:
1043261
Report Number(s):
SRNL-STI-20120-00344; TRN: US1203268
Country of Publication:
United States
Language:
English