Analysis of OH Bolted Ear Connection
The D0 endcap calorimeter outer hadronic (OH) modules play a major structural role in the calorimeter assembly. The disrete modules, once connected together, form a ring within which other massive calorimetry will reside. It has been proposed that the connection of the OH at the downstream end be accomplished by extending the downstream endplates in the radial direction to form 'ears', and then through-bolting between adjacent ears as shown in Fig. 1. A single 2 1/4 in. dia. bolt is used, and previous calculations have determined that the design load on this joint should be 130,000 lbs tension. The high load and serious consequences of failure make this a critical component in the calorimeter assembly. The purpose of this analysis is to investigate the stresses in the connection and other mechanical characteristics which determine joint performance.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1030685
- Report Number(s):
- FERMILAB-D0-EN-133; TRN: US201201%%338
- Country of Publication:
- United States
- Language:
- English
Similar Records
Design Review of the D0 Central Calorimeter Module Assembly to Fermi National Accelerator Laboratory
Diagnostic test systems canister weld joint analysis