Skip to main content
Log in

Fibrinogen Adsorption on Hydroxyapatite, Carbonate Apatite and Gold Surfaces In Situ Detected by Quartz Crystal Microbalance with Resistance Technique

  • Published:
MRS Online Proceedings Library Aims and scope

Abstract

When a biomaterial is implanted into the body, blood proteins adsorb on its surface and subsequently cells adhere via the protein adlayer. Thus, the understanding of protein adsorption and conformational change on the biomaterial surfaces is of great importance to control the biocompatibility such as antithrombotic properties and cell adhesion behaviors. In this study, we synthesized hydroxyapatite (HAp) and carbonate apatite (CAp) by a wet method. Then we successfully fabricated the HAp and CAp sensors for QCM-R by an electrophoretic deposition method. Adsorption behavior of proteins on the bone substitute material can be monitored by using these apatite sensors. Bovine serum albumin and fibrinogen were employed for the model proteins, and monitored the adsorption behavior on the HAp, CAp and reference gold (Au) sensors by the QCM-R technique. As a result, we revealed that fibrinogen and bovine serum albumin adsorbs on the gold surface by hydrophobic interaction, and adsorbs on the HAp and CAp surfaces mainly by electrostatic force. Besides, we revealed that fibrinogen adsorbs on the Au surface more rigid than on the HAp and CAp surfaces while bovine serum albumin adsorbs on the HAp and CAp surface more rigidly than on the Au surface.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Sergey V. Dorozhkin, J Mater Sci (2007) 42, 1061–1095.

    Article  CAS  Google Scholar 

  2. Toru Tonegawa, Toshiyuki Ikoma, Tomohiko Yoshioka, Nobutaka Hanagata, Junzo Tanaka, J Mater Sci (2010) 45: 2419–2426.

    Article  CAS  Google Scholar 

  3. Xiao-Li Su, Yanbin Li, “A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance,” Biosensors and Bioelectronics 21 (2005) 840–848.

    Article  CAS  Google Scholar 

  4. Kenneth A Marx, Tiean Zhou, Anne Montrone, Donna Mclntosh, Susan J. Braunhut, “Quartz crystal microbalance biosensor study of endothelial cells and their extracellular matrix following cell removal: Evidence for transient cellular stress and viscoelastic changes during detachment and the elastic behavior of the pure matrix,” Analytical Biochemistry 343 (2005) 23–24.

    Article  CAS  Google Scholar 

  5. Akira Monkawa, Toshiyuki Ikoma, Shunji Yunoki, Tomohiko Yoshioka, Junzo Tanaka, Dinko Chakarov, Bengt Kasemo, “Fabrication of hydroxyapatite ultra-thin layer on gold surface and its application for quartz crystal microbalance technique,” Biomaterials 27 (2006) 5748–5754.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yonekura, H., Tagaya, M., Yoshioka, T. et al. Fibrinogen Adsorption on Hydroxyapatite, Carbonate Apatite and Gold Surfaces In Situ Detected by Quartz Crystal Microbalance with Resistance Technique. MRS Online Proceedings Library 1418, 247–252 (2012). https://doi.org/10.1557/opl.2012.397

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1557/opl.2012.397

Navigation