Skip to content
BY-NC-ND 3.0 license Open Access Published by De Gruyter June 2, 2014

Measurement of Fluorescence Lifetimes of Coumarin Laser Dyes with a Mode-Locked Krypton Ion Laser

  • J. H. Richardson , L. L. Steinmetz , S. B. Deutscher , W. A. Bookless and W. L. Schmelzinger

Abstract

The fluorescence lifetime of four coumarin laser dyes (C-7, C-30, C-102, and C-120) were measured in three different solvents (methanol, ethanol and water) a t dilute and lasing concentrations. The lifetime generally decreases for the more hydrophobic dyes as the solvent polarity increases. There is little change with concentration due to the large Stokes shift.

Received: 1978-10-16
Published Online: 2014-6-2
Published in Print: 1978-12-1

© 1946 – 2014: Verlag der Zeitschrift für Naturforschung

This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.

Downloaded on 1.6.2024 from https://www.degruyter.com/document/doi/10.1515/zna-1978-1227/html