Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter September 16, 2014

A Load Frequency Control in an Off-Grid Sustainable Power System Based on a Parameter Adaptive PID-Type Fuzzy Controller

  • Ferdian Ronilaya EMAIL logo and Hajime Miyauchi

Abstract

This paper presents a new implementation of a parameter adaptive PID-type fuzzy controller (PAPIDfc) for a grid-supporting inverter of battery to alleviate frequency fluctuations in a wind-diesel power system. A variable speed wind turbine that drives a permanent magnet synchronous generator is assumed for demonstrations. The PAPIDfc controller is built from a set of control rules that adopts the droop method and uses only locally measurable frequency signal. The output control signal is determined from the knowledge base and the fuzzy inference. The input-derivative gain and the output-integral gain of the PAPIDfc are tuned online. To ensure safe battery operating limits, we also propose a protection scheme called intelligent battery protection (IBP). Several simulation experiments are performed by using MATLAB®/SimPowersystems™. Next, to verify the scheme’s effectiveness, the simulation results are compared with the results of conventional controllers. The results demonstrate the effectiveness of the PAPIDfc scheme to control a grid-supporting inverter of the battery in the reduction of frequency fluctuations.

References

1. BhattiT, Al-AdemiA, BansalN. Load frequency control of isolated wind diesel hybrid power systems. Energy Conversion Manage1997;38:82937.10.1016/S0196-8904(96)00108-2Search in Google Scholar

2. HowladerAM, IzumiY, UeharaA, UrasakiN, SenjyuT, YonaA, et al. A minimal order observer based frequency control strategy for an integrated wind-battery-diesel power system. Energy2012;46:16878.10.1016/j.energy.2012.08.039Search in Google Scholar

3. SebastianR, AlzolaRP. Effective active power control of a high penetration wind diesel system with a nicd battery energy storage. Renewable Energy2010;35:95265.10.1016/j.renene.2009.11.029Search in Google Scholar

4. HowladerAM, IzumiY, UeharaA, UrasakiN, SenjyuT, SaberAY. A robust h-inf controller based frequency control approach using the wind-battery coordination strategy in a small power system. Int J Electrical Power Energy Syst2014;58:1908.10.1016/j.ijepes.2014.01.024Search in Google Scholar

5. SerbanI, MarinescuC. Battery energy storage system for frequency support in microgrids and with enhanced control features for uninterruptible supply of local loads. Int J Electrical Power Energy Syst2014;54:43241.10.1016/j.ijepes.2013.07.004Search in Google Scholar

6. AnsariMM, VelusamiS. Dmlhflc (dual mode linguistic hedge fuzzy logic controller) for an isolated wind diesel hybrid power system with {BES} (battery energy storage) unit. Energy2010;35:382737.10.1016/j.energy.2010.05.037Search in Google Scholar

7. BarsaliS, CeraoloM, PelacchiP, PoliD. Control techniques of dispersed generators to improve the continuity of electricity supply. In: Power engineering society winter meeting, IEEE, volume 2, 2002;78994.Search in Google Scholar

8. ChandorkarM, DivanD, AdapaR. Control of parallel connected inverters in standalone ac supply systems. Ind Appl IEEE Trans1993;29:13643.10.1109/28.195899Search in Google Scholar

9. KawabataT, HigashinoS. Parallel operation of voltage source inverters. Ind Appl IEEE Trans1988;24:2817.10.1109/28.2868Search in Google Scholar

10. MatthiasH, HelmutS. Control of a three phase inverter feeding an unbalanced load and operating in parallel with other power sources. In: EPE-PEMC, 2002:110.Search in Google Scholar

11. TuladharA, JinK, UngerT, MauchK. Parallel operation of single phase inverter modules with no control interconnections. In: Applied power electronics conference and exposition, APEC ‘97 conference proceedings 1997, Twelfth Annual, volume 1, 1997:94100.Search in Google Scholar

12. GuerreroJM, Garcia de VicunaL, MatasJ, CastillaM, MiretJ. A wireless controller to enhance dynamic performance of parallel inverters in distributed generation systems. Power Electron IEEE Trans2004;19:120513.10.1109/TPEL.2004.833451Search in Google Scholar

13. De BrabandereK, BolsensB, Van den KeybusJ, WoyteA, DriesenJ, BelmansR. A voltage and frequency droop control method for parallel inverters. Power Electron IEEE Trans2007;22:110715.10.1109/TPEL.2007.900456Search in Google Scholar

14. VerbruggenH, BruijnP. Fuzzy control and conventional control: what is (and can be) the real contribution of fuzzy systems?Fuzzy Sets Syst1997;90:15160.10.1016/S0165-0114(97)00081-XSearch in Google Scholar

15. PandeySK, MohantySR, KishorN. A literature survey on load frequency control for conventional and distribution generation power systems. Renewable Sustainable Energy Rev2013;25:31834.10.1016/j.rser.2013.04.029Search in Google Scholar

16. TelekeS, BaranM, HuangA, BhattacharyaS, AndersonL. Control strategies for battery energy storage for wind farm dispatching. Energy Conversion IEEE Trans2009;24:72532.10.1109/TEC.2009.2016000Search in Google Scholar

17. KimJ-Y, KimS-K, JeonJ-H. Coordinated state-of-charge control strategy for microgrid during islanded operation. In: Power electronics for distributed generation systems (PEDG), 2012 3rd IEEE international symposium on, 2012:1339.Search in Google Scholar

18. YoshimotoK, NanaharaT, KoshimizuG. New control method for regulating state-of-charge of a battery in hybrid wind power/battery energy storage system. In: Power systems conference and exposition, PSCE ‘06. 2006 IEEE PES, 2006:124451.Search in Google Scholar

19. YeagerKE, WillisJR. Modeling of emergency diesel generators in an 800 megawatt nuclear power plant. Energy Conversion IEEE Trans1993;8:43341.10.1109/60.257056Search in Google Scholar

20. MuljadiE, PierceK, MiglioreP. A conservative control strategy for variable-speed stall-regulated wind turbines. In: The 19th American society of mechanical engineers (ASME) wind energy symposium, 2000:1013.10.2514/6.2000-31Search in Google Scholar

21. SlootwegJ, De HaanSW, PolinderH, KlingW. General model for representing variable speed wind turbines in power system dynamics simulations. Power Syst IEEE Trans2003;18:14451.10.1109/TPWRS.2002.807113Search in Google Scholar

22. PetruT, ThiringerT. Active flicker reduction from a sea-based 2.5mw wind park connected to a weak grid. In: Nordic workshop on power and industrial electronics (NORpie2000), Aalborg, Denmark, 2000:1316.Search in Google Scholar

23. KrugerT, AndresenB. Vesta optispeed advanced control strategy for variable speed wind turbines. In: European wind energy conference, Copenhagen, Denmark, 2001;9836.Search in Google Scholar

24. TremblayO, DessaintL. Experimental validation of a battery dynamic model for EV application. World Electric Vehicle J2009;3:110.10.3390/wevj3020289Search in Google Scholar

25. ChenZ, SpoonerE. Grid interface options for variable-speed, permanent-magnet generators. Electric Power Appl IEE Proc1998;145:27383.10.1049/ip-epa:19981981Search in Google Scholar

26. RonilayaF, MiyauchiH. Frequency and voltage control for an autonomous distributed variable-speed wind turbine based on a PID-type fuzzy controller with battery support. Int Rev Model Simulations2014;7:2708.Search in Google Scholar

27. QiaoWZ, MizumotoM. {PID} type fuzzy controller and parameters adaptive method. Fuzzy Sets Syst1996;78:2335.10.1016/0165-0114(95)00115-8Search in Google Scholar

28. YesilE, GuzelkayaM, EksinI. Self tuning fuzzy {PID} type load and frequency controller. Energy Conversion Manage2004;45:37790.10.1016/S0196-8904(03)00149-3Search in Google Scholar

29. BhattacharyaSK. Control systems engineering, 2nd ed. Patparganj, New Delhi: Dorling Kindersley (India) Pvt. Ltd.Search in Google Scholar

Published Online: 2014-9-16
Published in Print: 2014-10-1

©2014 by De Gruyter

Downloaded on 24.4.2024 from https://www.degruyter.com/document/doi/10.1515/ijeeps-2014-0094/html
Scroll to top button