Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter March 28, 2018

Towards Breath Gas Analysis Based on Millimeter-Wave Molecular Spectroscopy

  • Nick Rothbart EMAIL logo , Heinz-Wilhelm Hübers , Klaus Schmalz EMAIL logo , Johannes Borngräber and Dietmar Kissinger
From the journal Frequenz

Abstract

Breath gas analysis is a promising non-invasive tool for medical diagnosis as there are thousands of Volatile Organic Compounds (VOCs) in human breath that can be used as health monitoring markers. Millimeter-wave/terahertz molecular spectroscopy is highly suitable for breath gas analysis due to unique fingerprint spectra of many VOCs in that frequency range. We present our recent work on sensor systems for gas spectroscopy based on integrated transmitters (TX) and receivers (RX) fabricated in IHP’s 0.13 μm SiGe BiCMOS technology. For a single-band system, spectroscopic measurements and beam profiles are presented. The frequency is tuned by direct voltage-frequency tuning and by a fractional-n PLL, respectively. The spectroscopic system includes a folded gas absorption cell with gas pre-concentration abilities demonstrating the detection of a 50 ppm mixture of ethanol in ambient air corresponding to a minimum detectable concentration of 260 ppb. Finally, the design of a 3-band system covering frequencies from 225 to 273 GHz is introduced.

Funding statement: This work was supported in part by the Deutsche Forschungsgemeinschaft under the DFG project ESSENCE (No. SPP1857).

References

[1] W. Cao and Y. Duan, “Breath analysis: Potential for clinical diagnosis and exposure assessment,” Clin. Chem., vol. 52, no. 5, pp. 800–811, May, 2006.10.1373/clinchem.2005.063545Search in Google Scholar PubMed

[2] I. R. Medvedev, C. Neese, G. M. Plummer, and F. C. De Lucia, “Submillimeter spectroscopy for chemical analysis with absolute specificity,” Opt. Lett., vol. 35, no. 10, pp. 1533–1535, 2010.10.1364/OL.35.001533Search in Google Scholar PubMed

[3] A. M. Fosnight, B. L. Moran, and I. R. Medvedev, “Chemical analysis of exhaled human breath using a terahertz spectroscopic approach,” Appl. Phys. Lett., vol. 103, pp. 133703, 2013.10.1063/1.4823544Search in Google Scholar

[4] I. R. Medvedev, R. Schueler, J. Thomas, O. Kenneth, H.-J. Nam, N. Sharma, Q. Zhong, D. Lary, and P. Raskin, “Analysis of exhaled human breath via terahertz molecular spectroscopy,” in IEEE Proc. Infrared, Millimeter and Terahertz Wave (IRMMW-THz), Copenhagen, Denmark, Sept. 2016, pp. 1–2.10.1109/IRMMW-THz.2016.7758450Search in Google Scholar

[5] C. Wang and R. Han, “Dual-terahertz-comb spectrometer on CMOS for rapid, wide-range gas detection with absolute specificity,” IEEE J. Solid-State Circuits, vol. 52, no. 12, pp. 3361–3372, Dec, 2017.10.1109/JSSC.2017.2755693Search in Google Scholar

[6] K. Schmalz, N. Rothbart, P. F.-X. Neumaier, J. Borngräber, H.-W. Hübers, and D. Kissinger, “Gas spectroscopy system for breath analysis at mm-wave/THz using SiGe BiCMOS circuits,” IEEE Trans. Microw. Theory Tech., vol. 65, no. 5, pp. 1807–1818, 2017.10.1109/TMTT.2017.2650915Search in Google Scholar

[7] K. Schmalz, Y. Mao, J. Borngräber, P. Neumaier, and H.-W. Hübers, “Tunable 245 GHz transmitter and receiver in SiGe technology for gas spectroscopy,” Electron. Lett., vol. 50, no. 12, pp. 881–882, June, 2014.10.1049/el.2014.0625Search in Google Scholar

[8] K. Schmalz, R. Wang, W. Debski, H. Gulan, J. Borngräber, P. Neumaier, and H.-W. Hübers, “245 GHz SiGe sensor system for gas spectroscopy,” Int. J. Microwave Wireless Technologies, vol. 7, no. 3/4, pp. 271–278, 2015.10.1017/S1759078715000082Search in Google Scholar

[9] K. Schmalz, J. Borngräber, W. Debski, M. Elkhouly, R. Wang, P. Neumaier, and H.-W. Hübers, “245 GHz SiGe transmitter array for gas spectroscopy,” IEEE Trans. Terahertz Sci. Technol., vol. 6, no. 2, pp. 318–327, March, 2016.10.1109/TTHZ.2015.2513278Search in Google Scholar

[10] www.ihp-ffo.de/en/services/mpw-prototyping/.Search in Google Scholar

[11] P. Neumaier, K. Schmalz, J. Borngräber, D. Kissinger, and H.-W. Hübers, “Terahertz gas-sensors: Gas-phase spectroscopy and multivariate analysis for medical and security applications,” in SENSORS, 2015 IEEE, 2015, pp. 1909–1912.10.1109/ICSENS.2015.7370673Search in Google Scholar

[12] N. Rothbart, K. Schmalz, J. Borngraber, D. Kissinger, and H.-W. Hübers, “Gas spectroscopy by voltage-frequency tuning of a 245 GHz SiGe transmitter and receiver,” IEEE Sens. J., vol. 16, no. 24, pp. 8863–8864, Dec, 2016.10.1109/JSEN.2016.2615359Search in Google Scholar

[13] K. Schmalz, N. Rothbart, H.-W. Hübers, J. Borngräber, S. B. Yilmaz, and D. Kissinger, “Gas spectroscopy system with transmitters and receivers in SiGe BiCMOS for 225-273 GHz,” Proc. Of SPIE, vol. 10439, pp. 1, 2017.10.1117/12.2277310Search in Google Scholar

Received: 2018-1-9
Published Online: 2018-3-28
Published in Print: 2018-3-26

© 2018 Walter de Gruyter GmbH, Berlin/Boston

Downloaded on 25.5.2024 from https://www.degruyter.com/document/doi/10.1515/freq-2018-0015/html
Scroll to top button