Abstract
This paper is the eighth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37°C. The procedure described here is deduced from the previously described 30°C IFCC reference method. Differences are tabulated and commented on.
Clin Chem Lab Med 2006;44:1146–55.
References
1. Siekmann L, Bonora R, Burtis CA, Ceriotti F, Clerc-Renaud P, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes. Clin Chem Lab Med 2002; 40:631–4.10.1515/CCLM.2002.109Search in Google Scholar PubMed
2. Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Férard G, Ferrero CA, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 2. Reference procedure for the measurement of catalytic activity concentration of creatine kinase [ATP: creatine N-phosphotransferase (CK), EC 2.7.3.2]. Clin Chem Lab Med 2002; 40:635–42.Search in Google Scholar
3. Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Férard G, Ferrero CA, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 3. Reference procedure for the measurement of catalytic activity concentration of lactate dehydrogenase [L-lactate: NAD+ oxidoreductase (LDH), EC 1.1.1.27]. Clin Chem Lab Med 2002; 40:636–48.Search in Google Scholar
4. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Franck PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 4. Reference procedure for the measurement of catalytic activity concentration of alanine aminotransferase [L-alanine: 2-oxoglutarate aminotransferase (ALT), EC 2.6.1.2] Clin Chem Lab Med 2002; 40:718–24.Search in Google Scholar
5. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Franck PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 5. Reference procedure for the measurement of catalytic activity concentration of aspartate-aminotransferase [L-aspartate: 2-oxoglutarate-aminotransferase (AST), EC 2.6.1.1]. Clin Chem Lab Med 2002; 40:725–33.Search in Google Scholar
6. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Franck PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 6. Reference procedure for the measurement of catalytic activity concentration of γ-glutamyltransferase [(γ-glutamyl)-peptide: amino acid γ-glutamyltransferase (GGT), EC 2.3.2.2]. Clin Chem Lab Med 2002; 40:734–8.Search in Google Scholar
7. Siekmann L, Bonora R, Burtis CA, Ceriotti F, Clerc-Renaud P, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase according to IFCC procedures at 37°C. Clin Chem Lab Med 2002; 40:739–45.10.1515/CCLM.2002.127Search in Google Scholar PubMed
8. Lorentz K, International Federation of Clinical Chemistry (IFCC). Approved recommendation on IFCC methods for the measurement of catalytic concentration of enzymes. Part 9. IFCC method for α-amylase (1,4-α-D-glucan 4-glucanohydrolase, EC 3.2.1.1). Clin Chem Lab Med 1998; 36:185–203.10.1515/CCLM.1998.034Search in Google Scholar PubMed
9. Clinical and Laboratory Standards Institute. Preparation and testing of reagent water in the clinical laboratory; Proposed guideline, 4th ed.Search in Google Scholar
10. Linsinger T, Schimmel H, Pauwels J, Schumann G, Siekmann L. IRMM/IFCC information. Catalytic concentration of α-amylase determined by IFCC reference method at 37°C, IRMM/IFCC-460. EUR 19927 EN. IRMM/IFCC, 2001.Search in Google Scholar
©2006 by Walter de Gruyter Berlin New York