Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter February 23, 2012

Antimicrobial surface coatings for a permanent percutaneous passage in the concept of osseointegrated extremity prosthesis

  • Tilman Calliess EMAIL logo , Magda Sluszniak , Andreas Winkel , Cornelia Pfaffenroth , Wibke Dempwolf , Wieland Heuer , Henning Menzel , Henning Windhagen and Meike Stiesch

Abstract

The clinical implementation of percutaneous implants is still limited owing to infections at the side of the stoma. In our concept, this issue is addressed by designing copolymer surface coatings possessing biocompatibility and antimicrobial activity to improve the maintenance of a physiological skin seal at the skin-implant interface. Different copolymers with surface-active phosphonate and antimicrobial cationic groups were designed. Thus, coated titanium samples were cultured with bacterial strains or fibroblasts, respectively. Antimicrobial impact was evaluated by imaging the reduction of bacterial adherence. Biocompatibility was displayed by fibroblast proliferation and morphology. A variety of copolymers of 4-vinylpyridine with vinylbenzylphosphonate or dimethyl(2-methacryloyloxy-ethyl) phosphonate were prepared by free radical polymerization. The optimized polymer coating (copolymer D) showed a reduction of adherent bacteria up to 95%, with only a slight reduction in the adherence of human fibroblasts compared with blank titanium controls. In this study, we demonstrate in vitro that polymer surface coatings can be simultaneously antimicrobial and biocompatible. We consider this to be a promising technology for the realization of a permanent aseptic percutaneous passage as needed for the advancement of osseointegrated limb prosthesis.


Corresponding author: Dr. Tilman Calliess, Orthopädische Klinik der MHH im Annastift, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany Phone: +49-511-5354 593 Fax: +49-511-5354 682

The authors acknowledge financial support from the German Federal Ministry of Education and Research (promotional reference: 01EZ0775). The authors thank Drs. Richard Skiera and Michael Meier from Otto Bock HealthCare R&D for their valuable contribution to this study.

References

[1] Adden N, Gamble LJ, Castner DG, et al. Biocompatible polymer interlayers for binding proteins to titanium surfaces. Biomacromolecules 2006; 7: 2552–2559.10.1021/bm060473jSearch in Google Scholar PubMed

[2] Aschoff HH, Clausen A, Hoffmeister T. [The endo-exo femur prosthesis – a new concept of bone-guided, prosthetic rehabilitation following above-knee amputation]. Z Orthop Unfall 2009; 147: 610–615.10.1055/s-0029-1185893Search in Google Scholar PubMed

[3] Aschoff HH, Kennon RE, Keggi JM, Rubin LE. Transcutaneous, distal femoral, intramedullary attachment for above-the-knee prostheses: an endo-exo device. J Bone Joint Surg Am 2010; 92(Suppl 2): 180–186.10.2106/JBJS.J.00806Search in Google Scholar PubMed

[4] Branemark R, Branemark PI, Rydevik B, Myers RR. Osseointegration in skeletal reconstruction and rehabilitation: a review. J Rehabil Res Dev 2001; 38: 175–181.Search in Google Scholar

[5] Gidalevitz D, Ishitsuka Y, Muresan AS, et al. Interaction of antimicrobial peptide protegrin with biomembranes. Proc Natl Acad Sci USA 2003; 100: 6302–6307.10.1073/pnas.0934731100Search in Google Scholar PubMed PubMed Central

[6] Hagberg K, Branemark R. One hundred patients treated with osseointegrated transfemoral amputation prostheses – rehabilitation perspective. J Rehabil Res Dev 2009; 46: 331–344.10.1682/JRRD.2008.06.0080Search in Google Scholar

[7] Hagberg K, Branemark R, Gunterberg B, Rydevik B. Osseointegrated trans-femoral amputation prostheses: prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up. Prosthet Orthot Int 2008; 32: 29–41.10.1080/03093640701553922Search in Google Scholar PubMed

[8] Hagberg K, Haggstrom E, Uden M, Branemark R. Socket versus bone-anchored trans-femoral prostheses: hip range of motion and sitting comfort. Prosthet Orthot Int 2005; 29: 153–163.10.1080/03093640500238014Search in Google Scholar PubMed

[9] Heuer W, Winkel A, Kohorst P, et al. Assessment of the cytocompatibility of poly-(N-hexylvinylpyridinium) used as an antibacterial implant coating. Adv Eng Mater 2010; 12: B609–B617.10.1002/adem.201080030Search in Google Scholar

[10] Kuroda K, DeGrado WF. Amphiphilic polymethacrylate derivatives as antimicrobial agents. J Am Chem Soc 2005; 127: 4128–4129.10.1021/ja044205+Search in Google Scholar PubMed

[11] Middleton CA, Pendegrass CJ, Gordon D, Jacob J, Blunn GW. Fibronectin silanized titanium alloy: a bioinductive and durable coating to enhance fibroblast attachment in vitro. J Biomed Mater Res A 2007; 83: 1032–1038.10.1002/jbm.a.31382Search in Google Scholar PubMed

[12] Pendegrass CJ, Goodship AE, Blunn GW. Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses. Biomaterials 2006; 27: 4183–4191.10.1016/j.biomaterials.2006.03.041Search in Google Scholar PubMed

[13] Pendegrass CJ, Goodship AE, Price JS, Blunn GW. Nature’s answer to breaching the skin barrier: an innovative development for amputees. J Anat 2006; 209: 59–67.10.1111/j.1469-7580.2006.00595.xSearch in Google Scholar PubMed PubMed Central

[14] Pendegrass CJ, Gordon D, Middleton CA, Sun SN, Blunn GW. Sealing the skin barrier around transcutaneous implants: in vitro study of keratinocyte proliferation and adhesion in response to surface modifications of titanium alloy. J Bone Joint Surg Br 2008; 90: 114–121.10.1302/0301-620X.90B1.19580Search in Google Scholar PubMed

[15] Pendegrass CJ, Middleton CA, Gordon D, Jacob J, Blunn GW. Measuring the strength of dermal fibroblast attachment to functionalized titanium alloys in vitro. J Biomed Mater Res A 2010; 92: 1028–1037.Search in Google Scholar

[16] Pfaffenroth C, Winkel A, Dempwolf W, et al. Self-assembled antimicrobial and biocompatible copolymer films on titanium. Macromol Biosci 2011; 11: 1515–1525.10.1002/mabi.201100124Search in Google Scholar PubMed PubMed Central

[17] Tillander J, Hagberg K, Hagberg L, Branemark R. Osseointegrated titanium implants for limb prostheses attachments: infectious complications. Clin Orthop Relat Res 2010; 468: 2781–2788.10.1007/s11999-010-1370-0Search in Google Scholar PubMed PubMed Central

[18] Tiller JC, Liao CJ, Lewis K, Klibanov AM. Designing surfaces that kill bacteria on contact. Proc Natl Acad Sci USA 2001; 98: 5981–5985.10.1073/pnas.111143098Search in Google Scholar PubMed PubMed Central

[19] Ulman A. An introduction to ultrathin organic films – from Langmuir-Blodgett to self-assembly. Maryland Heights, MO/USA: Academic Press 1991. ISBN 978-0127082301.10.1016/B978-0-08-092631-5.50009-9Search in Google Scholar

Received: 2011-10-10
Accepted: 2011-12-22
Published Online: 2012-02-23
Published in Print: 2012-12-01

©2012 by Walter de Gruyter Berlin Boston

Downloaded on 1.5.2024 from https://www.degruyter.com/document/doi/10.1515/bmt-2011-0041/html
Scroll to top button