Skip to main content
Advertisement
  • Loading metrics

Simple, sensitive, and cost-effective detection of wAlbB Wolbachia in Aedes mosquitoes, using loop mediated isothermal amplification combined with the electrochemical biosensing method

  • Parinda Thayanukul ,

    Roles Formal analysis, Funding acquisition, Investigation, Methodology, Project administration, Validation, Visualization, Writing – original draft

    ‡ These authors are co-first authors on this work.

    Affiliations Center of Excellence for Vectors and Vector-Borne Diseases, Faculty of Science, Mahidol University at Salaya, Nakhon Pathom, Thailand, Department of Biology, Faculty of Science, Mahidol University, Bangkok, Thailand

  • Benchaporn Lertanantawong ,

    Roles Formal analysis, Investigation, Methodology, Project administration, Validation, Visualization, Writing – original draft

    ‡ These authors are co-first authors on this work.

    Affiliation Biosensors Laboratory, Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom, Thailand

  • Worachart Sirawaraporn,

    Roles Conceptualization, Formal analysis, Methodology, Supervision, Validation, Visualization, Writing – review & editing

    Affiliation Center of Excellence for Vectors and Vector-Borne Diseases, Faculty of Science, Mahidol University at Salaya, Nakhon Pathom, Thailand

  • Surat Charasmongkolcharoen,

    Roles Investigation, Methodology, Validation, Visualization

    Affiliation Department of Biology, Faculty of Science, Mahidol University, Bangkok, Thailand

  • Thanyarat Chaibun,

    Roles Investigation, Methodology, Validation, Visualization

    Affiliation Biosensors Laboratory, Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom, Thailand

  • Rattanalak Jittungdee,

    Roles Investigation, Methodology, Validation, Visualization

    Affiliation Department of Biology, Faculty of Science, Mahidol University, Bangkok, Thailand

  • Pattamaporn Kittayapong

    Roles Conceptualization, Formal analysis, Funding acquisition, Resources, Supervision, Validation, Visualization, Writing – review & editing

    pkittayapong@gmail.com

    Affiliations Center of Excellence for Vectors and Vector-Borne Diseases, Faculty of Science, Mahidol University at Salaya, Nakhon Pathom, Thailand, Department of Biology, Faculty of Science, Mahidol University, Bangkok, Thailand

Abstract

Background

Wolbachia is an endosymbiont bacterium generally found in about 40% of insects, including mosquitoes, but it is absent in Aedes aegypti which is an important vector of several arboviral diseases. The evidence that Wolbachia trans-infected Ae. aegypti mosquitoes lost their vectorial competence and became less capable of transmitting arboviruses to human hosts highlights the potential of using Wolbachia-based approaches for prevention and control of arboviral diseases. Recently, release of Wolbachia trans-infected Ae. aegypti has been deployed widely in many countries for the control of mosquito-borne viral diseases. Field surveillance and monitoring of Wolbachia presence in released mosquitoes is important for the success of these control programs. So far, a number of studies have reported the development of loop mediated isothermal amplification (LAMP) assays to detect Wolbachia in mosquitoes, but the methods still have some specificity and cost issues.

Methodology/Principal findings

We describe here the development of a LAMP assay combined with the DNA strand displacement-based electrochemical sensor (BIOSENSOR) method to detect wAlbB Wolbachia in trans-infected Ae. aegypti. Our developed LAMP primers used a low-cost dye detecting system and 4 oligo nucleotide primers which can reduce the cost of analysis while the specificity is comparable to the previous methods. The detection capacity of our LAMP technique was 1.4 nM and the detection limit reduced to 2.2 fM when combined with the BIOSENSOR. Our study demonstrates that a BIOSENSOR can also be applied as a stand-alone method for detecting Wolbachia; and it showed high sensitivity when used with the crude DNA extracts of macerated mosquito samples without DNA purification.

Conclusions/Significance

Our results suggest that both LAMP and BIOSENSOR, either used in combination or stand-alone, are robust and sensitive. The methods have good potential for routine detection of Wolbachia in mosquitoes during field surveillance and monitoring of Wolbachia-based release programs, especially in countries with limited resources.

Author summary

Mosquito-borne diseases such as dengue, chikungunya, zika, and yellow fever are transmitted to humans mainly by the bites of Aedes aegypti mosquitoes. Controlling the vectors of these diseases relies mostly on the use of insecticides. However, the efficiency has been reduced through the development of insecticide resistance in mosquitoes. Wolbachia is an endosymbiotic bacterium that is naturally found in 40% of insects, including mosquitoes. The bacterium can protect its insect hosts from viral infections and can also cause sterility in insect host populations, therefore, providing an opportunity to use it for human disease control. Application of a Wolbachia trans-infected mosquitoes needs simple, rapid and sensitive methods for detecting the bacteria in released mosquitoes. In this paper, we develop the methods of LAMP and BIOSENSORS for detecting wAlbB Wolbachia in mosquitoes. Our positive LAMP reaction can be visualized by color change from violet to blue at a sensitivity of ≥ 10 pg of genomic DNA. When used in combination with the BIOSENSOR method, the sensitivity increases a millionfold without losing specificity. Our study suggests that both developed methods, either used in combination or stand-alone, are efficient and cost-effective, hence, they could be applied for routine surveys of Wolbachia in mosquito control programs that use Wolbachia-based approaches.

Introduction

Dengue, chikungunya, zika, and yellow fever viruses, transmitted by the Aedes aegypti vector, continue to be a major health problem and affect human populations worldwide. Dengue is the most prevalent with an estimated 96 million symptomatic cases and 40,000 deaths every year [1]. Prevention of the transmission of these diseases, when vaccines have not yet been fully effective, depends primarily on two approaches, i.e., mosquito control and the interruption of human-vector contact such as using a mosquito net [2]. Historically, insecticides have been the primary means of mosquito control. However, the overuse and misuse of insecticides has resulted in several deleterious impacts on the environment and the emergence of insecticide-resistant mosquitoes [3]. Alternative vector control strategies are therefore important and need to be considered to effectively control the spread of these vector-borne diseases.

Wolbachia is an endosymbiont found intracellularly in about 40% of insect species [3]. The bacterium can manipulate host reproduction and inhibit virus intracellular replication [4,5]; hence it is potentially an effective alternative to traditional chemical pesticides. In mosquitoes, Wolbachia can induce cytoplasmic incompatibility (CI), a phenotype which results in the production of unviable offspring when uninfected females mate with Wolbachia-infected male mosquitoes. On the other hand, if Wolbachia-infected females mate with either infected or uninfected male mosquitoes, viable progenies harboring maternally transmitted Wolbachia will be produced. The effect of CI has received much attention, as it offers the potential application of Wolbachia in vector control. There have been a number of reports describing the stable establishment of Wolbachia in mosquitoes [68]. Since wild-type Ae. aegypti mosquitoes do not harbor Wolbachia [9], the introduction of Wolbachia into Ae. aegypti enabled disease control based on the CI and viral blockage properties. The use of Wolbachia-based approaches to reduce transmission of dengue, zika, and other viruses is currently being deployed and implemented widely in international programs in many countries [10,11]. Thus far many Wolbachia strains have been applied, including wMel, wMelPop, and wAlbB. In Northern Australia, Florida, and Malaysia, wAlbB-infected Ae. aegypti has been successfully deployed, while wAlbA- and wAlbB-superinfected Ae. aegypti was successfully implemented together with the sterile insect technique (SIT) in the pilot population suppression trial in Thailand [1215].

Although large-scale releases of Wolbachia trans-infected Ae. aegypti populations into the wild has been occurring in many countries, there remains critical issues with respect to the quality of the released mosquitoes. Surveillance of Wolbachia infection status is critical for the planning and deployment of proper mosquito control initiatives. Thus far, polymerase chain reaction (PCR) and qPCR techniques have been the gold standard methods used for detecting Wolbachia in mosquitoes [16,17]. However, the methods are laboratory based, require trained personnel, and use expensive instruments. Subsequently, loop-mediated isothermal amplification (LAMP), a highly sensitive and specific amplification of target DNA which requires only a heat-block, was developed and used for detecting Wolbachia in Ae. aegypti. To detect a diverse range of Wolbachia strains, LAMP primer sets were developed based on the 16S rRNA gene [18,19]. To evaluate the efficacy of the Wolbachia trans-infected mosquito interventions, LAMP primers specific to wAlbB and wMel strains were developed based on the Wolbachia surface protein gene (wsp) [20,21]. For the wAlbB strain, a high-fidelity detection system using LAMP combined with oligonucleotide strand displacement (OSD) probes, and enhancement of the LAMP reaction speed using two loops together with a real-time fluorescence detection machine (Genie1), have been developed [20,22]. Based on DNA sequence analysis, the original primer set reported previously [20] was shown to be able to detect some variants of Wolbachia wPip. Thus, the researchers suggested to label the primer loop with FAM to be the wAlbB vs wPip OSD probe for differentiating wPip [20]. Other researcher reported the application of this oligonucleotide sequence to be a loop WSP.FLP for increasing the detection speed [22]. Since applying many primers or using probe technology would increase the analysis cost, therefore using only 4 primers from other location(s) in the wAlbB wsp gene and applying a low-cost dye for LAMP analysis might be an alternative to have a more robust, sensitive, specific, but relatively low-cost LAMP detection method for the wAlbB-infected Ae. aegypti to detect Wolbachia in field released Ae. aegypti mosquitoes.

The LAMP products can be analyzed either by agarose gel electrophoresis or visual inspection of color or turbidity changes [23]. However, the disadvantage of the method is mis-diagnosis caused by a false positive or false negative. An alternative method to overcome the problem is the use of an electrochemical-DNA based biosensor, which employs gold-nanoparticles (AuNPs) to label nucleic acid [2427]. AuNP-labeled reporter probes (RP) are hybridized with capture probes (CP) on magnetic bead nanoparticles (MBs, Fe3O4 nanoparticles). The target strand complementary to the CP displaces the AuNP-labeled RP and binds to the CP. A displacement reaction is accelerated by changing the temperature or salt concentration. The unbound AuNP-labeled RP is then separated from the MB-CP bound RP using magnetic separation. The amount of displaced AuNP-RP represents the amount of target DNA and can be detected by a differential pulse anodic stripping voltammetry (DPASV) technique performed using a potentiostat. Similar techniques have been applied to the diagnosis of the arboviral diseases, including the dengue, chikungunya, and zika viruses [2831], but there has been very limited application in the mosquito sample [30]. The sensitivity of detection of these techniques were extremely high, with amounts as little as 1 PFU/ml being reported [30]. Some studies also showed the possibility of the technology being able to identify mosquito species and zika infection from mosquito salivary glands [29]. The extremely high sensitivity, together with the speed of detection allow the detection of low amount positive target as in the case of pooling samples in mosquito survey works. To our knowledge, no study has yet applied this technology to the detection of Wolbachia in mosquitoes.

In this paper, we describe the development of a combined LAMP and electrochemical-DNA based biosensor with strand displacement reaction method in order to detect wAlbB Wolbachia trans-infected Ae. aegypti mosquitoes. The conditions for LAMP and BIOSENSOR assays were also optimized as stand-alone techniques to be used for applications in other studies.

Methods

Ethics statement

The use of mosquito colony materials in this study was approved by the Faculty of Science, Mahidol University Animal Care and Use Committee (SCMU-ACUC) (Protocol No. MUSC64-005-554).

Mosquito materials and genomic DNA extraction

Long-term laboratory rearing colonies including Aedes aegypti (Aae-JJ, from Jatujak, Bangkok, Thailand), Aedes albopictus (Aal-CH, from Chachoengsao, Thailand), wAlbB trans-infected Thai Aedes aegypti (wAlbB-TH, from Thailand), and Culex quinquefasciatus (Cq-BK, from Bangkok, Thailand) were used in this study. The wAlbB trans-infected Thai Ae. aegypti were generated using the direct microinjection technique as previously described [6,12]. Field collected mosquitoes used in the BIOSENSOR experiments were obtained in the evening by a human-landing catch (HLC) method, using a hand-held mouth aspirator, at a house in Suphanburi Province, Thailand. The containers filled with mosquito samples were kept in a freezer at -20°C until analysis.

Genomic DNA was extracted from approximately 200 mosquitoes (mostly females) using a crude boiling method [32]. Briefly, a single mosquito was ground in 100 μl of sodium chloride-Tris-EDTA buffer (STE; 10 mM Tris-HCl pH 8.0, 1 mM EDTA and 100 mM NaCl), heated for 10 min at 95°C, and centrifuged at 16000 rpm for 10 min. Supernatant was transferred to a new tube and used as a template sample in subsequent LAMP, PCR, and DNA sensor reactions. For the mosquito pooled experiment, 10 μl STE was used for each mosquito [20], and the DNA extraction was performed following the method described above. A pooled mixture was created by combining a single female wAlbB infected Ae. aegypti (wAlbB-TH) with specified numbers of uninfected female Ae. aegypti (24, 49, 74, or 99) to obtain the ratios of 1/25, 1/50, 1/75, and 1/100.

LAMP primers and biosensor probe design

The sequence of the wsp gene of a wAlbB trans-infected Thai Ae. aegypti (NCBI accession number MZ325222) was applied for designing the LAMP primers. The sequence was identical to AF020059 wAlbB from Aedes albopictus (Houston strain) and MN307069 Wolbachia of Aedes aegypti isolate wAegB from the NCBI GenBank. This sequence was submitted to Primer Explorer v5 software (primerexplorer.jp/lampv5e/index.html, Eiken Chemical Co., Japan) to generate the potential primers used for the wAlbB LAMP detection. Several potential LAMP primer sets were generated. The primers were compared to various wsp sequences in the NCBI GenBank database. The DNA alignment was performed using MEGA 7.0.26 software with the default ClustalW algorithm [33]. The primer sets that bind to all wAlbB sequences but do not bind to many non-target Wolbachia strains were used for LAMP. The consensus region inside the LAMP priming site were used to construct biosensor probes (Table 1). A non-specific binding target was assessed by in silico analysis, where the primer sequences were compared with several wsp gene sequences from many strains in the NCBI database. All primers and probes were synthesized by Bio Basic Canada, Inc., Canada and Integrated DNA Technologies, USA, respectively.

thumbnail
Table 1. Oligonucleotide sequences of LAMP primers and target induced-DNA strand displacement probes used in this study.

https://doi.org/10.1371/journal.pntd.0009600.t001

LAMP assays

LAMP assays were performed in a total volume of 10–25 μl using Bst 2.0 WarmStart DNA Polymerase (New England Biolabs). The reagents, modified from Bhadra et al. (2018) [20], consisted of 1× Isothermal buffer (20 mM Tris-HCl, 10 mM (NH4)2SO4, 50 mM KCl, 2 mM MgSO4, 0.1% Tween 20, pH 8.8 at 25°C), 0.4 mM of dNTPs (10 mM each, Invitrogen, USA), 0.8 M Betaine solution (5 M, Sigma, USA), 2 mM MgSO4, 1.6 μM of each internal primer (FIP/BIP), 0.4 μM of each external primer (F3/B3), 6.4 units of Bst 2.0 DNA polymerase, 120 μM of hydroxy naphthol blue (HNB, Merck, Germany), and 4 μl DNA (diluted DNA supernanant 1:10 to obtain approximately 20–80 ng of DNA). HNB is a visualizing indicator of magnesium ion reduction due to the magnesium pyrophosphate formation by LAMP [23]. The developed LAMP assay was verified with Ae. albopictus naturally superinfected with wAlbA and wAlbB (Aal-CH), Cx. quinquefasciatus naturally infected with wPip [34] (Cq-BK), wild-type Ae. aegypti mosquitoes which do not harbor Wolbachia [9] (Aae-JJ), and wAlbB trans-infected Thai Ae. aegypti (wAlbB-TH). The mixture was incubated at 65°C for 90 min, followed by 80°C for 10 min. The concentrations of DNA (20–100 ng), Bst 2.0 (1.6–8.0 U), and the reaction time (60–90 mins) varied depending upon experimental purposes as indicated in the Results Section. Any comparisons made to the previously reported LAMP analysis method [20,22] were in reference to the results of those specific studies.

PCR reaction and analysis of gel electrophoresis

PCR detection of Wolbachia was performed according to the method previously described [35], using primers wsp 81F and 691R for general Wolbachia detection (~600 bp), primers 183F and 691R for wAlbB detection (~500 bp), and primers 328F and 691R for wAlbA detection (~380 bp) as a negative control. The reactions were performed using a final volume of 25 μl, and included 1.25 U Taq recombinant DNA polymerase (Invitrogen, USA), 1x PCR Buffer (w/o Mg), 3.75 mM MgCl2, 0.25 mM each dNTP (Invitrogen, USA), 0.5 μM each primer, and 1.0 μl template DNA. The amplifications were performed using a thermal cycler (T100 Thermo Cycler, Biorad, USA) with the following parameters: 1 cycle of 3 min at 94°C, 35 cycles of 45 sec at 94°C, 30 sec at 58°C, and 45 sec at 72°C, followed by 1 cycle of 10 min at 72°C. Five microliters of the PCR and LAMP products were mixed with 2 μl of loading dye, and were electrophoresed on a 2.0% (w/v) Agarose A gel (Biobasic, Canada) containing 0.2 μg/ml Ethidium Bromide (Sigma, USA) in 1xTBE buffer (pH 8.0) at 100 V for 40 min. DNA were visualized under UV light. The concentration of DNA was measured using NanoDrop One Microvolume UV-Vis Spectrophotometer (Thermo Fisher Scientific, USA).

Functionalization of AuNPs conjugate with reporter probe

Preparation of AuNPs–reporter conjugate probe (AuRP) was performed using a salt aging method [27]. Briefly, 10 μl of 100 μM reporter probe DNA and 30 μl of 100 μM blocking probe (PolyT10) thiolated DNA were activated by using freshly prepared 10 mM Tris (2-carboxyethyl) phosphine (TCEP, Sigma-Aldric, USA). Then, the thiol-activated DNA was added into 1 ml of 40 nM AuNPs solution (DCN Diagnostics, USA) and incubated overnight at room temperature. After incubation, the solution of 10 μl of 500 mM Tris-acetate pH 8.2 and 100 μl of 1 M NaCl was added into the mixture and stored overnight at room temperature. The probes were obtained by centrifugation at 14,000 rpm for 30 min, followed by washing 3 times with 25 mM Tris-acetate pH 7.4, resuspended with hybridization buffer, and storage at 4°C until use.

Immobilization of capture probe onto magnetic beads

The immobilization of the biotinylated capture probe (CP) on the magnetic bead (MB) (Dynabeads T1, Thermo Fisher Scientific, USA) was performed according to the manufacturer’s instructions. Briefly, a 100 μl volume of MB (10 μg/μl) was washed 3 times with 200 μl of 20 mM PBS pH 7.4, mixed with 4 μl of 100 μM capture probe, 12 μl of 100 μM blocking probe, and 184 μl of 20 mM PBS pH 7.4, and then incubated for 40 min at room temperature. The MB-bound probe was washed 3 times with 20 mM PBS pH 7.4, resuspended with 100 μl of 20 mM PBS pH 7.4, and stored at 4°C until use. This conjugation was subsequently called the magnetic bead conjugated capture probe DNA (MB-CP).

DNA hybridization and DNA strand displacement reaction

The prehybridization step of MB-CP and AuRP was prepared as follows: 2 μl of MB-CP and 10 μl of AuRP were added into 18 μl of 20 mM PBS/0.1% SDS pH 7.4, and incubated for 20 min at 45°C in a water bath. The prehybridized MB-CP and AuRP was then washed 3 times with 20 mM PBS pH 7.4 using magnet collection. The pellet was used for a DNA strand displacement experiment. For DNA strand displacement, 30 μl of target DNA was added to resuspend the pellet and then incubate at 60°C for 30 min. A magnet was used to separate the target DNA bound to MB-CP from the unbound AuNPs-reporter conjugate probe. The five microliters of the supernatant was used for signal detection.

Electrochemical detection of AuRP from DNA strand displacement reaction

Displaced AuRP was detected by using electrochemical measurement by the differential pulse anodic stripping voltammetry (DPASV) technique on a portable Palmsens 4 computer-controlled potentiostat with PSTrace version 5.7 software (Palmsens, The Netherlands). Two electrode systems, screened printed carbon electrodes or SPCE (Quesence, Thailand), consisting of two carbon tracks as a working electrode, reference electrode, and counter electrode in DPASV, were used. Five microliters of the desired sample was loaded onto a working electrode surface, followed by 50 μl of 1 M hydrobromic acid (HBr)/0.1 M bromine solution (Br2). For the pre-treatment step, the condition for deposition potential was -0.75 V and the deposition time was 100 sec. The step potential was set at 0.005 V, with a 0.1 sec interval time. The modulation amplitude was 0.1 V and the modulation time was 0.05 sec.

Detection of nucleic acid derived from wAlbB

The products of the wAlbB LAMP reaction with a single female mosquito and PCR of wsp genes, wAlbA wsp gene, and wAlbB wsp gene in single female mosquito samples were applied to the biosensor detection. In addition, the unamplified macerated single female mosquito samples from the laboratory colonies (Aal-CH, Aae-JJ, wAlbB-TH) and those from the field collection were used in this study. The concentration of the DNA was determined by measuring the absorbance at 260 nm, using the NanoDrop One Microvolume UV-Vis Spectrophotometer (USA) in the DNA strand displacement platform, followed by differential pulse anodic stripping voltammetry (DPASV) detection. Five replications were performed for each detection.

Results

LAMP primer and probe design

The wsp genes of Wolbachia trans-infected Thai Ae. aegypti were sequenced. This sequence was compared to 17 wsp genes of Wolbachia wAlbB in mosquitoes from the NCBI database. The consensus region of 230 bp was submitted to PrimerExplorer software. The recommended LAMP primer sets were compared to 686 sequences of wsp genes from 66 Wolbachia strains [3436] and all wsp genes of Ae. aegypti and Ae. albopictus in the database from Sanger or genome sequencing (data available upon request). The set of sequences that could bind to all wAlbB sequences and were different from most other strains were selected (Table 1).

All FIC, BIC, F3, and B3 primers with 6 priming sites have to bind altogether in order to produce massive DNA cauliflower complexes for LAMP detection [37]. By comparing the wsp gene sequences downloaded from NCBI database with the LAMP primers from our work and the Wolbachia wsp LAMP-OSD assay in the previous study [20], it was shown that our primers could bind to Wolbachia variants in mosquitoes in addition to wAlbB (non-target binding), including wAegB in Ae. aegypti (MN307069), wPseu in Aedes pseudalbopictus (AF317487), Wolbachia in some Armigeres subalbatus (KY457720) and Armigeres obturbans (KJ140130, KJ140132). The non-target bindings of LAMP primers found in this study were possible to be bound to the primer set in the previous study [20], except for wPseu. The previous LAMP set could bind more to wPip in Cx. quinquefasciatus (AF020061). However, this research also suggested to use their loop sequence for the OSD probe, which would eliminate the binding of wPip. In silico analysis suggested that our newly designed LAMP primers would be highly specific to the wAlbB strain, with specificity comparable to the wAlbB LAMP primer set previously reported [20,22].

The new primers B3, FIP, and BIP in the present study had higher GC content (40–42%). The GC content was near the recommended range for good binding primers of 50–60% [38]. Our LAMP primers had a melting temperature in the range of 55.2–61.3°C, where the ΔG values of 3′ and 5′ ends were -6.24 to -4.07 kcal/mol and -5.69 to -4.02 kcal/mol, respectively, and the ΔG of dimer (minimum) formation was -2.16 kcal/mol. For the capture probe design, we selected the consensus region overlapping with the F1c binding area, so as to increase the attachment of the probe to the structures of complex LAMP products (Fig 1).

thumbnail
Fig 1. Schematic diagram demonstrates the LAMP primers and probe binding locations on the target sequence of the wAlbB wsp gene.

Grey boxes indicate the primer sequences. Grey letters are the complementary sequence of the wAlbB sequence in the 5′-3′ direction. Blue and red fonts indicate the capture and reporter probes, respectively.

https://doi.org/10.1371/journal.pntd.0009600.g001

Verification and optimization of LAMP assay

The developed LAMP primer set was used to examine the presence of Wolbachia in mosquito samples, i.e., Ae. albopictus (Aal-CH), Cx. quinquefasciatus (Cq-BK), wild-type Ae. aegypti (Aae-JJ), and wAlbB trans-infected Thai Ae. aegypti (wAlbB-TH) (Fig 2). The LAMP assay in Fig 2 clearly shows positive Wolbachia detection for the Wobachia trans-infected Thai Ae. aegypti, Ae. albopictus, and Cx. quinquefasciatus, as indicated by the blue color of HNB in the reactions and the presence of a ladder-like band pattern upon gel electrophoresis, while wild-type Ae. aegypti and the control reaction (no-template control (NTC)) were negative as indicated by a purple color in the HNB reactions and the lack of bands upon gel electrophoresis. These results agreed with the gold standard PCR method, suggesting the potential of these newly designed LAMP primers to detect Wolbachia infection in mosquitoes.

thumbnail
Fig 2.

Detection of Wolbachia wAlbB gene in different mosquito species using LAMP assay with HNB indicator (A) and ethidium bromide-stained gel (B): (1) no template control, (2) wild-type Aedes aegypti (AegW, Aae-JJ), (3) Wobachia trans-infected Thai Ae. aegypti (AegB, wAlbB-TH), (4) Aedes albopictus (Alb, Aal-CH), and (5) Culex quinquefasciatus (Cq-BK). M is 1 kb plus DNA Ladder from Invitrogen. The condition for LAMP reaction was 6.4 units of Bst 2.0 DNA polymerase, 65°C for 60 min and 80°C for 10 min.

https://doi.org/10.1371/journal.pntd.0009600.g002

It is noteworthy that, as predicted from in silico analysis, all primers except for B3 could bind to the wsp sequence of the laboratory Cx. quinquefasciatus (MZ325223, Cq-BK). B3 contained one mis-matched base close to the 3′prime end. Although, theoretically LAMP will amplify only if the four primers are bound to a template with six priming regions, non-specific amplification may happen if the primers have the mismatch at the 3′prime end [39]. The detection of Cx. quinquefasciatus is an example of a non-target detection due to one mismatched base near the 3′prime end of the primer (Fig 2). However, wPip was a variant of Wolbachia pipientis in different hosts to the wAlbB [35], therefore the detection of wPip in Cx. quinquefasciatus by the wAlbB LAMP primers was possible. The previous LAMP-OSD assay also detected wPip in Cx. quinquefasciatus in their study, although they created an additional probe to differentiate wPip [20]. In addition, to verify the efficiency of indicating the presence of wAlbB strain, we repeated the test with 52 Ae. albopictus (Aal-CH), 30 wAlbB trans-infected Thai Ae. aegypti (wAlbB-TH), 31 wild-type Ae. aegypti (Aae-JJ), and 3 Cx quinquefasciatus (Cq-BK) (S1 Fig). All confirmed tests gave the results which were in good agreement with prior investigation, and that positive wAlbB LAMP assay was found in Aal-CH, wAlbB-TH, and Cq-BK mosquito samples, while the negative LAMP result was found in Aae-JJ.

To optimize LAMP detection, the concentration of the DNA template was examined. Ae. albopictus (Aal-CH) and wAlbB trans-infected Thai Ae. aegypti (wAlbB-TH) were used as positive controls. Wild type Ae. aegypti (Aae-JJ) and NTC were used as negative controls. The amounts of DNA template were varied between 20 and 100 ng (S2 Fig). The ladder-like bands were observed for Ae. albopictus and wAlbB trans-infected Thai Ae. aegypti samples for all template amounts, which were in contrast to the results of wild-type Ae. aegypti and NTC. Wild-type Ae. aegypti showed a darker blue-purple color closer to the positive control at a higher amount of DNA. However, at the DNA amount of 100 ng, the color from the wild-type Ae. aegypti reaction could not be differentiated from that of the positive reaction. Therefore, the amount of DNA should be controlled in a range of 20–80 ng, with the most recommended DNA amount being 20 ng. However, the quality of the DNA may be a matter of concern.

The LAMP assay was tested with different Bst polymerase concentrations from 1.6–8.0 units (S1 Table). The color development between the positive and negative control was more distinguished at higher concentrations of Bst (3.2–8.0 units). At 1.6 units of Bst, a false negative result was obtained for the Wolbachia trans-infected Thai Ae. aegypti (wAlbB-TH). Hence, Bst at concentrations of 3.2–6.4 units were recommended for cost saving and visual observation. However, in the present study, we used 6.4 units of Bst, as this amount of enzyme was used in many previous studies [18,20,40].

We also tried to vary the LAMP reaction time at 60 and 90 min for the 20 and 40 ng template DNA (S3 Fig). The HNB and gel results were positive for Ae. albopictus (P in S3 Fig, Aal-CH) and negative for NTC at both 60 and 90 mins for 20 and 40 ng DNA. However, the blue lavender color in the 60-min reaction of Ae. albopictus at 40 ng was ambiguous for visual observation. Therefore, 90 min was recommended. This is consistent with previous studies which also suggested 90 min for LAMP amplification [18,20]. Besides, the concentration of HNB used in this study was only 0.12 mM, which is 10-times less than that reported in the previous work [18]. However, the range of HNB dye concentration could be varied without affecting the LAMP reaction.

We also tested the stability of reagent mixture (- template) stored in a freezer (-20°C) to minimize errors caused by pipetting. Upon adding the DNA template, the LAMP reagent stored up to 30 days amplified the wAlbB trans-infected Thai Ae. aegypti, as indicated by the ladder-like band in an agarose gel (S4 Fig); although, the faint blue color could be observed when the reagent was stored up to 90 days. Based on our results, the reagent could be stored at -20°C for only 30 days.

The LAMP reaction was performed with diluted DNA from the wAlbB trans-infected Thai Ae. aegypti (wAlbB-TH, 182 ng/μl) in a total reaction volume of 10 μl with 1 μl DNA template. In Fig 3, LAMP could amplify the positive samples up to 20,000 folds (10−4/2 dilution), which was equivalent to 1.4 nM of DNA. Nevertheless, LAMP failed to detect DNA at a concentration below 0.56 nM. On another hand, PCR yielded a very faint band at a DNA concentration of 10−3-fold (or equivalent to 28 nM of DNA). LAMP had at least 20 times higher sensitivity than PCR. We concluded that the limit of detection (LOD) of LAMP in this study was 1.4 nM. In addition, the sensitivity of mosquito detection in pooled samples was tested. In Fig 3, LAMP could detect the presence of one wAlbB infected Ae. aegypti (wAlbB-TH) among 99 wild-type Ae. aegypti (Aae-JJ); while PCR could not detect the pool of one wAlbB-TH among 24 Aae-JJ. These results agreed with previous research [20,22].

thumbnail
Fig 3.

Sensitivity of LAMP (A and B) and PCR (C) detections with sample dilution experiment (Left) and mosquito pool sample experiment (Right). LAMP assay with ethidium bromide-stained gel (A) and HNB indicator (B) of a fold-dilution of an individual crude boiling Aedes aegypti (wAlbB-TH) sample (182 ng/μl, 260/280 = 1.90, 260/230 = 0.99) diluted 10−1–10−6 times (6.4 units of Bst 2.0 DNA polymerase, 65°C for 90 min and 80°C for 10 min, volume 10 μl). Polymerase chain reaction with wsp primers (691R and 183F) of the same dilution (C). (O) is a non-diluted original sample, (P) is Wolbachia trans-infected Ae. aegypti (wAlbB-TH), (N1) is wild-type Ae. aegypti (Aae-JJ), (N2) is 100 wild-type Ae. aegypti (Aae-JJ), (NTC) is no template control, (M) is Invitrogen 100 bp DNA Ladder. For mosquito pooled experiment, the ratio of 1/25 indicates the DNA extraction was performed with one Wolbachia trans-infected Ae. aegypti and 24 wild-type Ae. aegypti. Other pooled samples included 1/50, 1/75, and 1/100, which were equivalent to one wAlbB-TH mosquito in 49, 74, and 99 Aae-JJ, respectively.

https://doi.org/10.1371/journal.pntd.0009600.g003

DNA sensors assay

Biosensor was applied to increase the sensitivity of LAMP detection and to reduce ambiguity in LAMP visualization. Fig 4 shows the sensitivity of the strand displacement method with a synthetic wAlbB linear target using electrochemical detection. The results showed the LOD of 2.2 fM for the target DNA (5 Signals/Noise). The linear range was 1 fM to 1 μM (R2 = 0.93). The electrochemical target strand displacement platform had a much higher sensitivity than the LAMP and PCR techniques in a magnitude of 106. Therefore, the sensitivity of Wolbachia DNA detection could be enhanced dramatically by using the electrochemical DNA sensors technology.

thumbnail
Fig 4. Calibration curve of synthetic wAlbB linear target strand displacement platform using electrochemical detection.

https://doi.org/10.1371/journal.pntd.0009600.g004

We applied this BIOSENSOR technology to the LAMP amplified samples (Fig 5-L). The results obtained from electrochemical detection clearly showed a good discrimination between wAlbB-infected mosquitoes (L.Alb and L.AegB) and non-infected mosquitoes (L.AegW). For the positive target, PCR products of Wolbachia detection with general wsp primers of the mosquitoes containing wAlbB (P.wsp Alb, P.wsp AegB, P.wAlbB Alb, and P.wAlbB AegB) were detected. The detection signal for negative samples from the mosquitoes without wAlbB (P.wsp AegW) were lower than the threshold value at 30 nA, approximately four-time blank signal, as shown in Fig 5. In addition, electrochemical detection with the wAlbB targeting capture probe did not respond to the PCR product of wAlbA (P.wAlbA Alb); though the mosquito DNA templates contained wAlbB. This test could effectively separate the detection of wAlbA and wAlbB.

thumbnail
Fig 5. Electrochemical detection of wAlbB LAMP products (L) and PCR products (P).

PCR reactions were performed for the general wsp gene (81F/691R), wAlbA gene (328F/691R), and wAlbB gene (183F/691R). Different mosquito species were included as follows: wild-type Aedes aegypti (AegW, Aae-JJ), wAlbB trans-infected Thai Ae. aegypti (AegB, wAlbB-TH), and Aedes albopictus (Alb, Aal-CH). Samples giving peak currents above 30 nA (approximately four-times blank signal) were considered positive. The bar charts represent the mean of 5 replications of DPV measurement and standard deviation was shown. Different patterns indicate either PCR or LAMP reaction products. Colors indicate mosquito colonies.

https://doi.org/10.1371/journal.pntd.0009600.g005

Since we discovered high sensitivity of Wolbachia detection with the electrochemical DNA sensors, we applied it to test the presence of the wAlbB region directly in the macerated single mosquito samples without any in vitro amplification. Fig 6 demonstrates positive detection for wAlbB trans-infected Thai Ae. aegypti (ML.AegB1-2), Ae. albopictus (ML.Alb1 and MF.Alb1-2), and Cx. vishnui (MF.Cx.vis1-3), as well as negative detection for wild-type Ae. aegypti (ML.AegW1-2 and MF.AegW1-2) and Cx. gelidus (MF.Cx.gel1-2) from both laboratory colonies and field samples. As mentioned earlier, most of the studies reported no Wolbachia infection in wild-type Ae. aegypti and superinfection by wAlbA and wAlbB in Ae. albopictus. We obtained a negative result for the wild-type Ae. aegypti and a positive result for the Ae. albopictus. However, our biosensor platform detected a positive signal in Cx. vishnui although the only available wsp gene sequence of Cx. vishnui (GQ469981) in the NCBI database did not match with the capture probe sequence. Previous studies reported that the infection of wCon belongs to the Supergroup B for Cx. vishnui [9,41,42]. Culex vishnui may have different wsp strains or wAlbB that could bind to our probe. More Wolbachia survey in Cx. vishnui should be conducted in the future. The reported wsp gene sequences in Cx. gelidus (GQ469982.2 and AF317482) did not match with the sequence of the capture probe, and they belong to Supergroup A [4142], which was consistent with the DNA sensor results obtained in this study. Although the detection might not be specific to only the wAlbB variant in Ae aegypti, other possible detected strains were in Supergroup B which are Wolbachia pipientis variants in different hosts [35]. In addition, a combination of the conventional morphological taxonomy and the molecular detection of mosquito species biomarkers [20,22] could simply differentiate the mosquitoes in Aedes and Culex groups with different Wolbachia strains.

thumbnail
Fig 6. Electrochemical detection of macerated mosquitoes of laboratory colonies (ML) and field samples (MF).

Different mosquito species were included as follows: wild-type Aedes aegypti (AegW, if ML: Aae-JJ), wAlbB trans-infected Thai Ae. aegypti (AegB, wAlbB-TH), Aedes albopictus (Alb, if ML: Aal-CH), Culex gelidus (Cx.gel) and Culex vishnui (Cx.vis). Samples giving peak currents above 30 nA (approximately four-times blank signal) were considered positive. The bar charts represent the mean of 5 replications of DPV measurement and standard deviation was shown. Different patterns indicate either laboratory colony or field samples. Colors indicate different mosquito colonies or species.

https://doi.org/10.1371/journal.pntd.0009600.g006

Discussion

This study developed a LAMP combined with the electrochemical detection of AuRP from a DNA strand displacement platform for detection of the wAlbB strain of Wolbachia bacteria. The methods, i.e., LAMP assay, LAMP plus BIOSENSOR assay, and BIOSENSOR assay alone, could be applied as surveillance and monitoring tools for Wolbachia trans-infected Ae. aegypti release programs. Since most studies thus far reported an absence of Wolbachia in the wild-type Ae. aegypti [9,17,41,4344], it can be assumed that the Wolbachia in Ae. aegypti detected in the field surveillance and monitoring study is likely from the release programs.

Although there were few previous studies reporting the detection of natural infection of Wolbachia in Ae. aegypti [4552], the Wolbachia detection methods in these studies employed only molecular approaches which are prone to contamination and may be subjected to horizontal gene transfer from the larvae or parasitic nematodes nearby or mis-identification of a naturally infected Wolbachia mosquito such as Ae. albopictus. Only two studies reported the successful establishment of laboratory colonies of Wolbachia-infected Ae. aegypti and demonstrated the inherited vertical transmission of Wolbachia to F2 [19] and F4 [45] generations. In another independent study [17], however, the cytoplasmic incompatibility and the molecular detection on the putatively Wolbachia-infected Ae. aegypti Las Cruces colony (New Mexico) of the previous work [19] were examined, but Wolbachia in this colony could not be found. Therefore, the authors concluded that the evidence of Wolbachia in Ae. aegypti was not compelling [17]. Regarding the intangible evidence of Wolbachia infection in natural Ae. aegypti, comprehensive monitoring of the infection status of Wolbachia should be continued, especially prior to the release of Wolbachia trans-infected mosquitoes. Our detection schemes using LAMP, BIOSENSOR, or a combination could serve this purpose well, as these methods are much more sensitive (Figs 3 and 4) than the conventional PCR method and can reduce the need for laboratory equipment and molecular biology specialists. However, LAMP and BIOSENSOR still need PCR approaches and precise morphological or molecular species detections for accurate confirmation of the Wolbachia detection in Ae. aegypti as shown in Fig 2 that wAlbB LAMP could amplified wPip in Cx. quinquefasciatus.

Regarding the cost of analysis as shown in the S2 Table, LAMP reagents would cost around $0.6–$1.5/reaction, while PCR or qPCR costs around $0.7–$1.0/reaction. Approximate cost for a DNA sensor would be $2.0. The crude DNA extraction costs less than $0.5 per sample; though the DNA extraction kit might cost up to $10 per sample. In addition, LAMP required only a single heat block and perhaps a clean UV cabinet which cost around $1,200, while PCR will cost at least $5,500 and qPCR will be at least $40,000. The electrochemical detection of BIOSENSOR costs around $1,300. Notably, cost estimation varies greatly across geographic locations and inflation condition. The cost analysis here is mainly based on the prices in Thailand. Needless to say, both LAMP and BIOSENSOR, including the combination, would greatly increase the speed and sensitivity of Wolbachia detection compared to PCR based techniques. Therefore, these methods are very suitable for application in the field, where assessment of expensive molecular laboratory instruments is limited. However, LAMP cannot be used to quantify Wolbachia load, which is the prime ability of qPCR and biosensor. Each technique has its own advantages and disadvantages, and each will be more suited to certain scenarios. A comparison of different approaches for wAlbB Wolbachia detection in mosquitoes in terms of purposes, abilities, assay times, and costs were summarized in S2 Table.

A number of recent works, and also commercial products, support the possibility of preparing the LAMP reagent in freeze-dried form. Other studies showed that the lyophilized LAMP reagents remained stable for 24 months when stored at 4°C, 28 days at 25°C, and 2 days at 37°C, or at least 55 days at room temperature [53,54]. In addition, it is also possible to prepare the strand displacement biosensor reagent in the lyophilized prehybridization mixture. A previous study demonstrated that the prehybridization mixture stored at 4°C is stable up to 3 months without significant decrease in the current signal [27]. However, a decrease of 18% and 30% in the current signal was found in the mixture stored at 25°C and an outdoor ambient temperature (24–34°C) for 50 days, respectively. Further study is needed to apply the lyophilization technique to the Wolbachia detecting reagent so as to facilitate the studies which have limited resource settings.

The storage period of the dead mosquito bodies is also an important concern for a field survey. A previous work reported that 6 among 10 mosquito samples kept at -20°C for 7 days gave a positive color as compared to the color of the no-template-control [20]. For samples kept at 14 days and 21 days, 5 and 1 mosquito samples, respectively, among the 10 total samples each were positive. However, we could detect LAMP wAlbB positive in all trans-infected Thai Ae. aegypti (wAlbB-TH) mosquitoes (n = 6) stored at -20°C for 15 months (Fig 3); while in one batch of wAlbB-TH, LAMP reaction could amplify 2 among 3 mosquito samples kept at -20°C for up to 10 days (S5 Fig). However, the storage period of mosquito samples for LAMP analysis might be dependent on Wolbachia load in different culturing conditions and mosquito colonies. Detection of Wolbachia from dead mosquitoes stored in a dry condition up to 30 days at 26°C and 10 days at 37°C has been reported [22]. The use of the Genie1 III machine with real-time fluorescence detection was found to increase the sensitivity and reliability of typical LAMP detections with gel electrophoresis and color development [22]. The speed of detection could be increased to 6–12 mins using 6 LAMP primers (including 2 loops) [22]. For LAMP analysis, we found that DNA concentration is an important factor related to the accuracy of LAMP amplification (S2 Fig). Too high DNA content (>100 ng) resulted in a false positive detection by visual judgement. However, controlling the amount of DNA can be a challenging task in resource-limited settings. Without the ability to accurately quantify DNA, we recommend researchers to follow our DNA extraction protocol (1 mosquito in 100 μl of lysis buffer, diluted DNA supernanant 1:10) and LAMP reagent preparation procedure (4 μl in 25 μl reaction mixture). By following this ratio, the DNA concentration should be in the appropriate range of 20–80 ng DNA.

Since the tonality of HNB color (purple to blue) could give false positive or negative results by naked eyes observation, replications should often be conducted to minimize these false positive and negative results and to increase reliability of detection. This technique needs a comparison with the color of a negative control (mosquito without Wolbachia wAlbB) and an experienced observer for judgement. We also observed some ambiguous results which required confirmation by a gel electrophoresis technique. The electrochemical DNA sensor could extend the reliability of detection. However, if one applies only LAMP, other dye such as SYBR Green I (orange to green) [55], cresol red (red to yellow) [56], phenol red plus cresol red (purple to yellow) [57], or GeneFinder (red to green) [58] might be used. HNB has the advantage of cost (inexpensive), ease of use, and stability of color (2–3 weeks) [58,59]. LAMP is often prone to contamination; therefore, separation of a specific clean plastic cabinet for master mix preparation, and sample addition in a clean open bench-top, could reduce the contamination problem.

Based on the In silico analysis, one of our LAMP primer (B3) could not bind to the wPip strain in Cx. quinquefasciatus, though we observed a positive result with the DNA sample from Cx. quinquefasciatus mosquito in Fig 2. There was one mis-matched base near the 3’ end of the B3 primer. Together with all other LAMP primers, it is likely to be due to non-specific amplification. The modification by adding a fluorescence probe, as in the case of the LAMP-OSD probe in a previous study [20], can increase the specificity because LAMP will visualize only the probe binding fragments. If the LAMP primer set in the previous studies [20,22] was applied with the low-cost dye such as HNB, our LAMP primer set should have a comparable specificity to the wAlbB as the sequence analysis of both primer sets showed only one mismatched to wPip sequence near the 3’end. Since both wPip and wAlbB are variation sequences of Wolbachia pipientis in different hosts (Culex and Aedes, respectively), which may have minor different characteristics [35], with the classical morphological or molecular species identification, it is possible to differentiate these variants. However, if it is important for some specific study, the modified wAlbB vs wPip OSD in the other research work [20] is recommended, as the probe technology can increase the specificity. In fact, the previous LAMP-OSD primer modified wAlbB vs wPip OSD [20], and the modified set with two loops addition were shown to be able to increase the detection speed [22], and were possible to be used together with low-cost dyes. Therefore, our LAMP primer would be an alternative method to other previous studies.

For future development of the biosensing method, a previous work reported the development of a lateral flow biosensor on the nitrocellulose membrane for visual detection of dengue virus using dextrin-capped AuNP as label [31]. A positive test generated a red test line on the strip, which enabled simple visual detection. Another interesting research work applied the aptamer–gold nanoparticle conjugates for the colorimetric detection of Ae. aegypti and zika virus from the mosquito salivary glands [29]. This might be further developed to be a non-invasive disease-vector monitoring tool such as wick-based feeding device and membrane-based sensor that may be visualized from the mosquito abdomen color or saliva absorbing membrane.

The LAMP primers and electrochemical biosensing method with strand displacement platform were successfully employed to detect mosquito samples containing the wAlbB strain of Wolbachia bacteria. The tests provided high sensitivity and specificity suitable for field surveys of mosquito distribution in Wolbachia-based projects using wAlbB trans-infected Ae. aegypti and for monitoring natural Wolbachia infections in wild-type Ae. aegypti. This knowledge has the potential to have a tremendous impact on the field of biological control of mosquito vectors, which in turn could reverse the increasing burden of arboviral illnesses worldwide.

Supporting information

S1 Fig.

Detection of Wolbachia wAlbB gene using LAMP assays with Ethidium bromide-stained gel of different mosquito species including Aedes albopictus (Aal-CH) (1), Aedes aegypti (Aae-JJ) (2), and Wolbachia trans-infected Thai Aedes aegypti (wAlbB-TH) (3), and Culex quinquefasciatus (Cq-BK) (4). (N) is no-template control and (M) is Invitrogen 1 Kb Plus DNA Ladder. LAMP reaction was performed using 3.2 units of Bst 2.0 DNA polymerase at 65°C for 90 min.

https://doi.org/10.1371/journal.pntd.0009600.s001

(TIFF)

S2 Fig.

Detection of Wolbachia wAlbB gene using LAMP assays with Ethidium bromide-stained gel (A) and Hydroxy Naphthol Blue indicator (B) under different DNA template mass of the different mosquito species including Aedes albopictus (Aal-CH) (1), Aedes aegypti (Aae-JJ) (2), and Wolbachia trans-infected Thai Ae. aegypti (wAlbB-TH) (3). (N) is no-template control and (M) is Invitrogen 1 Kb Plus DNA Ladder. The sizes of DNA (bp) were indicated. LAMP reaction was performed using 3.2 units of Bst 2.0 DNA polymerase at 65°C for 90 min.

https://doi.org/10.1371/journal.pntd.0009600.s002

(TIFF)

S3 Fig.

Detection of Wolbachia wAlbB gene using LAMP assays with Hydroxy Naphthol Blue indicator (A) and Ethidium bromide-stained gel (B) under different incubation times for 60 and 90 mins with a DNA template of 20 and 40 ng. P is Aedes albopictus (Aal-CH) and N is no-template control. M is Invitrogen 1 Kb Plus DNA Ladder. The sizes of DNA (bp) were indicated. LAMP reaction was performed using 3.2 units of Bst 2.0 DNA polymerase at 65°C for 90 min.

https://doi.org/10.1371/journal.pntd.0009600.s003

(TIFF)

S4 Fig.

Detection of Wolbachia wAlbB gene using LAMP assays with Ethidium bromide-stained gel (A) and Hydroxy Naphthol Blue indicator (B) with a LAMP reagent mixture (- template) stored in a 20°C freezer. P is Aedes albopictus (Aal-CH) and N is wild-type Aedes aegypti (Aae-JJ), and NT is no-template control (NTC). Triplicate sets were performed but one example result was shown here. M is Invitrogen 1 Kb Plus DNA Ladder. The sizes of DNA (bp) were indicated. LAMP reaction was performed using 6.4 units of Bst 2.0 DNA polymerase at 65°C for 60 min and 80°C for 10 min.

https://doi.org/10.1371/journal.pntd.0009600.s004

(TIFF)

S5 Fig.

Detection of Wolbachia wAlbB gene using LAMP assays with Ethidium bromide stained gel (upper) and Hydroxy Naphthol Blue indicator (lower) with the dead mosquitoes stored at different temperatures including -20°C (A), 4°C (B), 27°C (C), and 37°C (D). 1–3 are wAlbB infected Aedes aegypti mosquitoes. P is Aedes albopictus. N is wild-type Aedes aegypti, and NT is no-template control (NTC). M is Invitrogen 100 bp or 1kb plus DNA Ladder. The sizes of DNA (bp) were indicated. LAMP reaction was performed using 6.4 units of Bst 2.0 DNA polymerase, 65°C for 60 min and 80°C for 10 min.

https://doi.org/10.1371/journal.pntd.0009600.s005

(TIFF)

S1 Table. Detection of Wolbachia wAlbB gene using LAMP assays with Hydroxy Naphthol Blue indicator under different Bst 2.0 Polymerase concentrations of the different mosquito species.

N is no-template control. LAMP reaction was performed at 65°C for 90 min.

https://doi.org/10.1371/journal.pntd.0009600.s006

(TIFF)

S2 Table. Comparison of different approaches for wAlbB Wolbachia detection in mosquitoes.

https://doi.org/10.1371/journal.pntd.0009600.s007

(TIFF)

Acknowledgments

The authors would like to thank Dr. Lee Su Yin from AIMST University; Dr. Surang Chankhamhaengdecha, Dr. Thanawat Sridapan, Miss Nuanla-ong Kaeothaisong from Mahidol University for their technical assistance; and Mr. David Blyler for English editing.

References

  1. 1. World Health Organization (WHO). Vector-borne diseases. WHO Website Newsroom: World Health Organization (WHO); 2020 [updated 2 March 2020; cited 2021 29 September 2021]. Available from: https://www.who.int/news-room/fact-sheets/detail/vector-borne-diseases.
  2. 2. World Health Organization (WHO). Guidelines on the quality, safety and efficacy of dengue tetravalent vaccines (live, attenuated). 2013 8 October 2013. Report No.: 979. pmid:24340361
  3. 3. McGraw EA O’Neill SL. Beyond insecticides: New thinking on an ancient problem. Nature Reviews Microbiology. 2013;11(3):181–93. pmid:23411863
  4. 4. Werren JH, Baldo L, Clark ME. Wolbachia: Master manipulators of invertebrate biology. Nature Reviews Microbiology. 2008;6(10):741–51. pmid:18794912
  5. 5. Moreira LA, Iturbe-Ormaetxe I, Jeffery JA, Lu G, Pyke AT, Hedges LM, et al. A Wolbachia symbiont in Aedes aegypti limits infection with dengue, chikungunya, and Plasmodium. Cell. 2009;139(7):1268–78. pmid:20064373
  6. 6. Ruang-Areerate T, Kittayapong P. Wolbachia transinfection in Aedes aegypti: A potential gene driver of dengue vectors. Proceedings of the National Academy of Sciences of the United States of America. 2006;103(33):12534–9. Epub 2006/08/08. pmid:16895998
  7. 7. Hoffmann AA, Montgomery BL, Popovici J, Iturbe-Ormaetxe I, Johnson PH, Muzzi F, et al. Successful establishment of Wolbachia in Aedes populations to suppress dengue transmission. Nature. 2011;476(7361):454–7. pmid:21866160
  8. 8. McMeniman CJ, Lane RV, Cass BN, Fong AWC, Sidhu M, Wang Y-F, et al. Stable introduction of a life-shortening Wolbachia infection into the mosquito Aedes aegypti. Science. 2009;323(5910):141–4. pmid:19119237
  9. 9. Kittayapong P, Baisley KJ, Baimai V, O’Neill SL. Distribution and diversity of Wolbachia infections in Southeast Asian mosquitoes (Diptera: Culicidae). Journal of Medical Entomology. 2000;37(3):340–5. pmid:15535575
  10. 10. Flores HA, O’Neill SL. Controlling vector-borne diseases by releasing modified mosquitoes. Nature Reviews Microbiology. 2018;16(8):508–18. pmid:29777177
  11. 11. World mosquito program. How our method compares 2021 [cited 2021 12 April 2021]. Available from: https://www.worldmosquitoprogram.org/en/learn/how-our-method-compares.
  12. 12. Kittayapong P, Ninphanomchai S, Limohpasmanee W, Chansang C, Chansang U, Mongkalangoon P. Combined sterile insect technique and incompatible insect technique: The first proof-of-concept to suppress Aedes aegypti vector populations in semi-rural settings in Thailand. PLoS Neglected Tropical Diseases. 2019;13(10):e0007771–e. pmid:31658265
  13. 13. Pagendam DE, Trewin BJ, Snoad N, Ritchie SA, Hoffmann AA, Staunton KM, et al. Modelling the Wolbachia incompatible insect technique: Strategies for effective mosquito population elimination. BMC Biology. 2020;18(1):161. pmid:33158442
  14. 14. Mains JW, Kelly PH, Dobson KL, Petrie WD, Dobson SL. Localized control of Aedes aegypti (Diptera: Culicidae) in Miami, FL, via inundative releases of Wolbachia-infected male mosquitoes. Journal of Medical Entomology. 2019;56(5):1296–303. pmid:31008514
  15. 15. Nazni WA, Hoffmann AA, NoorAfizah A, Cheong YL, Mancini MV, Golding N, et al. Establishment of Wolbachia strain wAlbB in Malaysian populations of Aedes aegypti for dengue control. Current Biology. 2019;29(24):4241–8.e5. pmid:31761702
  16. 16. Ricci I, Cancrini G, Gabrielli S, D’amelio S, Favia G. Searching for Wolbachia (Rickettsiales: Rickettsiaceae) in mosquitoes (Diptera: Culicidae): Large polymerase chain reaction survey and new identifications. Journal of Medical Entomology. 2002;39(4):562–7. pmid:12144285
  17. 17. Ross PA, Callahan AG, Yang Q, Jasper M, Arif MAK, Afizah AN, et al. An elusive endosymbiont: Does Wolbachia occur naturally in Aedes aegypti? Ecology and Evolution. 2020;10(3):1581–91. pmid:32076535
  18. 18. Gonçalves DdS Cassimiro APA, de Oliveira CD Rodrigues NB, Moreira LA. Wolbachia detection in insects through LAMP: loop mediated isothermal amplification. Parasites and Vectors. 2014;7(1):228. pmid:24885509
  19. 19. Kulkarni A, Yu W, Jiang J, Sanchez C, Karna AK, Martinez KJL, et al. Wolbachia pipientis occurs in Aedes aegypti populations in New Mexico and Florida, USA. Ecology and Evolution. 2019;9(10):6148–56. pmid:31161026
  20. 20. Bhadra S, Riedel TE, Saldaña MA, Hegde S, Pederson N, Hughes GL, et al. Direct nucleic acid analysis of mosquitoes for high fidelity species identification and detection of Wolbachia using a cellphone. PLoS Neglected Tropical Diseases. 2018;12(8):e0006671. pmid:30161131
  21. 21. Gonçalves DdS, Hooker DJ, Dong Y, Baran N, Kyrylos P, Iturbe-Ormaetxe I, et al. Detecting wMel Wolbachia in field-collected Aedes aegypti mosquitoes using loop-mediated isothermal amplification (LAMP). Parasites and Vectors. 2019;12(1):404. pmid:31416478
  22. 22. Jasper ME, Yang Q, Ross PA, Endersby-Harshman N, Bell N, Hoffmann AA. A LAMP assay for the rapid and robust assessment of Wolbachia infection in Aedes aegypti under field and laboratory conditions. PLoS ONE. 2019;14(11):e0225321. pmid:31747432
  23. 23. Zhang X, Lowe SB, Gooding JJ. Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP). Biosensors and Bioelectronics. 2014;61:491–9. pmid:24949822
  24. 24. Kuan GC, Sheng LP, Rijiravanich P, Marimuthu K, Ravichandran M, Yin LS, et al. Gold-nanoparticle based electrochemical DNA sensor for the detection of fish pathogen Aphanomyces invadans. Talanta. 2013;117:312–7. pmid:24209346
  25. 25. Liew PS, Lertanantawong B, Lee SY, Manickam R, Lee YH, Surareungchai WJT. Electrochemical genosensor assay using lyophilized gold nanoparticles/latex microsphere label for detection of Vibrio cholerae. Talanta. 2015;139:167–73. pmid:25882423
  26. 26. Cajigas S, Alzate D, Orozco J. Gold nanoparticle/DNA-based nanobioconjugate for electrochemical detection of zika virus. Microchimica Acta. 2020;187(11):594. pmid:33026568
  27. 27. Ngamdee T, Yin LS, Vongpunsawad S, Poovorawan Y, Surareungchai W, Lertanantawong B. Target induced-DNA strand displacement reaction using gold nanoparticle labeling for hepatitis E virus detection. Analytica Chimica Acta. 2020;1134:10–7. pmid:33059855
  28. 28. George A, Amrutha MS, Srivastava P, Sunil S, Sai VVR, Srinivasan R. Development of a U-bent plastic optical fiber biosensor with plasmonic labels for the detection of chikungunya non-structural protein 3. Analyst. 2021;146(1):244–52. pmid:33107522
  29. 29. Bosak A, Saraf N, Willenberg A, Kwan MWC, Alto BW, Jackson GW, et al. Aptamer–gold nanoparticle conjugates for the colorimetric detection of arboviruses and vector mosquito species. Royal Society of Chemistry Advances. 2019;9(41):23752–63. pmid:35530619
  30. 30. Cheng MS, Ho JS, Tan CH, Wong JPS, Ng LC, Toh C-S. Development of an electrochemical membrane-based nanobiosensor for ultrasensitive detection of dengue virus. Analytica Chimica Acta. 2012;725:74–80. pmid:22502614
  31. 31. Yrad FM, Castañares JM, Alocilja EC. Visual detection of Dengue-1 RNA using gold nanoparticle-based lateral flow biosensor. Diagnostics. 2019;9(3):74. pmid:31336721
  32. 32. Ahantarig A, Trinachartvanit W, Kittayapong P. Relative Wolbachia density of field-collected Aedes albopictus mosquitoes in Thailand. Journal of Vector Ecology. 2008;33(1):173–7. pmid:18697321
  33. 33. Kumar S, Stecher G, Tamura K. MEGA7: Molecular Evolutionary Genetics Analysis version 7.0 for bigger datasets. Molecular Biology and Evolution. 2016;33:1870–4. pmid:27004904
  34. 34. Ruang-Areerate T, Kittyapong P, Baimai V, O’Neill SL. Molecular phylogeny of Wolbachia endosymbionts in Southeast Asian mosquitoes (Diptera: Culicidae) based on wsp Gene Sequences. Journal of Medical Entomology. 2003;40(1):1–5. pmid:12597646
  35. 35. Zhou W, Rousset F, O’Neill S. Phylogeny and PCR-based classification of Wolbachia strains using wsp gene sequences. Proceedings of Biological Sciences. 1998;265(1395):509–15. pmid:9569669.
  36. 36. Silva LMId Dezordi FZ, Paiva MHS Wallau GL. Systematic review of Wolbachia symbiont detection in mosquitoes: An entangled topic about methodological power and true symbiosis. Pathogens. 2021;10(1):39. pmid:33419044
  37. 37. Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Research. 2000;28(12):E63–E. pmid:10871386.
  38. 38. Eiken Chemical Co. Ltd. A Guide to LAMP primer designing (PrimerExplorer V5) 2019. Available from: https://primerexplorer.jp/e/v5_manual/index.html.
  39. 39. Zhou Y, Wan Z, Yang S, Li Y, Li M, Wang B, et al. A mismatch-tolerant reverse transcription loop-mediated isothermal amplification method and its application on simultaneous detection of all four serotype of dengue viruses. Frontiers in Microbiology. 2019;10:1056–. pmid:31139171.
  40. 40. Zhou D, Guo J, Xu L, Gao S, Lin Q, Wu Q, et al. Establishment and application of a loop-mediated isothermal amplification (LAMP) system for detection of cry1Ac transgenic sugarcane. Scientific Reports. 2014;4(1):4912. pmid:24810230
  41. 41. Mohanty I, Rath A, Swain SP, Pradhan N, Hazra RK. Wolbachia population in vectors and non-vectors: A sustainable approach towards dengue control. Current Microbiology. 2019;76(2):133–43. pmid:30426159
  42. 42. Ravikumar H, Ramachandraswamy N, Puttaraju HP. Molecular strain typing of Wolbachia infection from Indian mosquitoes using wsp gene. Asian Pacific Journal of Tropical Diseases. 2011;1(2):106–9. https://doi.org/10.1016/S2222-1808(11)60046-7.
  43. 43. Soni M, Bhattacharya C, Sharma J, Khan SA, Dutta P. Molecular typing and phylogeny of Wolbachia: A study from Assam, North-Eastern part of India. Acta Tropica. 2017;176:421–6. pmid:28939497
  44. 44. Gloria-Soria A, Chiodo TG, Powell JR. Lack of evidence for natural Wolbachia infections in Aedes aegypti (Diptera: Culicidae). Journal of Medical Entomology. 2018;55(5):1354–6. pmid:29901734
  45. 45. Balaji S, Jayachandran S, Prabagaran SR. Evidence for the natural occurrence of Wolbachia in Aedes aegypti mosquitoes. Federation of European Microbiological Societies, Microbiology Letters. 2019;366(6). pmid:30869785
  46. 46. Thongsripong P, Chandler JA, Green AB, Kittayapong P, Wilcox BA, Kapan DD, et al. Mosquito vector-associated microbiota: Metabarcoding bacteria and eukaryotic symbionts across habitat types in Thailand endemic for dengue and other arthropod-borne diseases. Ecology and Evolution. 2018;8(2):1352–68. pmid:29375803
  47. 47. Carvajal TM, Hashimoto K, Harnandika RK, Amalin DM, Watanabe K. Detection of Wolbachia in field-collected Aedes aegypti mosquitoes in metropolitan Manila, Philippines. Parasites and Vectors. 2019;12(1):361. pmid:31340862
  48. 48. Wong ML, Liew JWK, Wong WK, Pramasivan S, Mohamed Hassan N, Wan Sulaiman WY, et al. Natural Wolbachia infection in field-collected Anopheles and other mosquito species from Malaysia. Parasites and Vectors. 2020;13(1):414. pmid:32787974
  49. 49. Teo CHJ, Lim PKC, Voon K, Mak JW. Detection of dengue viruses and Wolbachia in Aedes aegypti and Aedes albopictus larvae from four urban localities in Kuala Lumpur, Malaysia. Tropical Biomedicine. 2017;34(3):583–97. pmid:33592927
  50. 50. Coon KL, Brown MR, Strand MR. Mosquitoes host communities of bacteria that are essential for development but vary greatly between local habitats. Molecular Ecology. 2016;25(22):5806–26. pmid:27718295
  51. 51. Hegde S, Khanipov K, Albayrak L, Golovko G, Pimenova M, Saldaña MA, et al. Microbiome interaction networks and community structure from laboratory-reared and field-collected Aedes aegypti, Aedes albopictus, and Culex quinquefasciatus mosquito vectors. Frontiers in Microbiology. 2018;9(2160). pmid:30250462
  52. 52. Bennett KL, Gómez-Martínez C, Chin Y, Saltonstall K, McMillan WO, Rovira JR, et al. Dynamics and diversity of bacteria associated with the disease vectors Aedes aegypti and Aedes albopictus. Scientific Reports. 2019;9(1):12160. pmid:31434963
  53. 53. Chen H-W, Ching W-M. Evaluation of the stability of lyophilized loop-mediated isothermal amplification reagents for the detection of Coxiella burnetii. Heliyon. 2017;3(10):e00415. pmid:29057336
  54. 54. Carter C, Akrami K, Hall D, Smith D, Aronoff-Spencer E. Lyophilized visually readable loop-mediated isothermal reverse transcriptase nucleic acid amplification test for detection Ebola Zaire RNA. Journal of Virological Methods. 2017;244:32–8. pmid:28242293
  55. 55. Zhang Y, Shan X, Shi L, Lu X, Tang S, Wang Y, et al. Development of a fimY-based loop-mediated isothermal amplification assay for detection of Salmonella in food. Food Research International. 2012;45(2):1011–5. https://doi.org/10.1016/j.foodres.2011.02.015.
  56. 56. Gou H, Bian Z, Cai R, Jiang Z, Song S, Li Y, et al. The colorimetric isothermal multiple-self-matching-initiated amplification using cresol red for rapid and sensitive detection of porcine circovirus 3. Frontiers in Veterinary Science. 2020;7:407,p.1–7. pmid:32851005
  57. 57. Ji J, Xu X, Wu Q, Wang X, Li W, Yao L, et al. Simple and visible detection of duck hepatitis B virus in ducks and geese using loop-mediated isothermal amplification. Poultry Science. 2020;99(2):791–6. pmid:32029161
  58. 58. Almasi M, Ojaghkandi M, Hemmatabadi A, Hamidi F, Aghaei S. Development of colorimetric loop-mediated isothermal amplification assay for rapid detection of the tomato yellow leaf curl virus. Journal of Plant Pathology and Microbiology. 2013;4(1).
  59. 59. Wastling SL, Picozzi K, Kakembo ASL, Welburn SC. LAMP for human African Trypanosomiasis: A comparative study of detection formats. PLoS Neglected Tropical Diseases. 2010;4(11):e865. pmid:21072228