日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
下向き閉塞分岐配管に生じる流動と温度変動のメカニズム : 第1報,鉛直分岐配管に生じる流動現象(流体工学,流体機械)
大厩 徹中村 晶長谷 正紹細川 茂雄竹中 信幸
著者情報
ジャーナル フリー

2009 年 75 巻 749 号 p. 68-76

詳細
抄録

Numerous pipes branch off from main pipe in power plant facilities. Main flow initiates a cavity flow in the downward branch pipe with a closed end and thermally stratified layer may form in the branch pipe if there is significant temperature difference in main and branch fluid. Fluctuation of thermally stratified layer may initiate thermal fatigue crack in the branch pipe. Flow visualization experiment was conducted to understand detailed behavior of the layer, for vertical branch pipe with a closed end. The penetration length of main flow in the branch pipe was measured for various main flow velocities. The velocity distributions in the penetrating flow region were obtained by a LDV method. The temperature fluctuation near the thermally stratified layer was measured. Through these experiments it was found that; (1) the driving force of the fluctuations in the branch pipe was not due to thermal phenomena but fluctuation of the spiral flow; (2) the flow regime in the second region was simple structured forced vortex with constant angular velocity, (3) steady thermally stratified layer did not fluctuate periodically in the vertical pipe.

著者関連情報
© 2009 社団法人日本機械学会
前の記事 次の記事
feedback
Top