Skip to main content

Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?

Abstract

Background

An increase in cardiac index (CI) during an end-expiratory occlusion test (EEOt) predicts fluid responsiveness in ventilated patients. However, if CI monitoring is unavailable or the echocardiographic window is difficult, using the carotid Doppler (CD) could be a feasible alternative to track CI changes. This study investigates whether changes in CD peak velocity (CDPV) and corrected flow time (cFT) during an EEOt were correlated with CI changes and if CDPV and cFT changes predicted fluid responsiveness in patients with septic shock.

Methods

Prospective, single-center study in adults with hemodynamic instability. The CDPV and cFT on carotid artery Doppler and hemodynamic variables from the pulse contour analysis EV1000™ were recorded at baseline, during a 20-s EEOt, and after fluid challenge (500 mL). We defined responders as those who increased CI ≥ 15% after a fluid challenge.

Results

We performed 44 measurements in 18 mechanically ventilated patients with septic shock and without arrhythmias. The fluid responsiveness rate was 43.2%. The changes in CDPV were significantly correlated with changes in CI during EEOt (r = 0.51 [0.26–0.71]). A significant, albeit lower correlation, was found for cFT (r = 0.35 [0.1–0.58]). An increase in CI ≥ 5.35% during EEOt predicted fluid responsiveness with 78.9% sensitivity and 91.7% specificity, with an area under the ROC curve (AUROC) of 0.85. An increase in CDPV ≥ 10.5% during an EEOt predicted fluid responsiveness with 96.2% specificity and 53.0% sensitivity with an AUROC of 0.74. Sixty-one percent of CDPV measurements (from − 13.5 to 9.5 cm/s) fell within the gray zone. The cFT changes during EEOt did not accurately predict fluid responsiveness.

Conclusions

In septic shock patients without arrhythmias, an increase in CDPV greater than 10.5% during a 20-s EEOt predicted fluid responsiveness with > 95% specificity. Carotid Doppler combined with EEOt may help optimize preload when invasive hemodynamic monitoring is unavailable. However, the 61% gray zone is a major limitation (retrospectively registered on Clinicaltrials.gov NCT04470856 on July 14, 2020).

Background

Fluid responsiveness is defined as an increase in cardiac index (CI) in response to an increase in preload [1]. In patients with hemodynamic instability, detecting fluid responsiveness with high specificity may avoid an unnecessary fluid load, which could be associated with increased morbidity, mortality, and hospital length of stay [2, 3].

Several functional hemodynamic tests for assessing fluid responsiveness have been introduced in clinical practice in the last few years [4]. These tests measure the hemodynamic response to a transient variation in cardiac preload induced by changes in body position, as is the case of passive leg raising (PLR) [5, 6], or by changes in intrathoracic pressure induced by a transient increase in tidal volume [7, 8], a lung recruitment or sigh maneuver [9, 10], or an end-expiratory occlusion test (EEOt) [11].

The EEOt is based on an interruption of mechanical ventilation at the end of expiration for 15–30 s. This maneuver increases cardiac preload, venous return, and stroke volume (SV) in preload-responsive patients. In one study [11], an increase in CI ≥ 5% during a 15-s EEOt reliably predicted an increase in CI by > 15% in response to a 500-mL crystalloid infusion with a sensitivity and a specificity of 91% and 100%, respectively. The accuracy of EEOt in predicting fluid responsiveness is comparable to that of PLR [12]. However, detecting the rapid and transient increase in CI during the EEOt needs continuous hemodynamic monitoring. In previous studies, this has been achieved using pulse contour arterial waveform analysis [7, 11, 13,14,15] or changes in velocity–time integral (VTI) assessed by trans-thoracic echocardiography (TTE) [16, 17]. When invasive hemodynamic monitoring is unavailable, or TTE cannot be obtained, carotid Doppler could be a feasible alternative to track changes in SVI or CI induced by EEOt. The variations in the systolic peak velocity and the duration of the systolic component of each cardiac cycle, measured from the onset to the dicrotic notch, provide an estimate of the changes in stroke volume [18,19,20]. However, the potential of carotid Doppler to assess fluid responsiveness in combination with EEOt in critical care patients has not been investigated yet.

We conducted this study to assess (1) if there was a correlation between the changes in carotid Doppler peak velocity (CDPV) or in corrected flow time (cFT) and the changes in CI induced by a 20-s EEOt; (2) if EEOt-induced changes in CDPV and cFT predict fluid responsiveness in patients admitted to intensive care unit (ICU) with septic shock.

Methods

Patient population

The institutional review board of Policlinico Agostino Gemelli University Hospital approved the present study (Prot. N. 0048329/18 ID 1677) retrospectively registered on ClinicalTrials.gov NCT04470856 on July 14, 2020. All patients or their legal representatives gave their written informed consent to participate.

All adult patients (≥ 18 y) admitted to the general ICU of Policlinico Agostino Gemelli University Hospital with a diagnosis of septic shock who were sedated and mechanically ventilated were considered for inclusion. Patients were eligible if they needed a fluid challenge according to predefined clinical criteria: (1) hypotension (defined as a systolic arterial pressure ≤ 90 mmHg) and/or (2) tachycardia (i.e., ≥ 100 beats/min) and/or (3) urinary flow ≤ 0.5 mL/kg/min for 2 h. Those with significant valvular heart disease, cardiac arrhythmia, heart failure, peripheral arterial disease, or common carotid artery stenosis narrower than 50% were excluded from the study.

Intervention

All patients were supine with their trunk elevated 30°, sedated, paralyzed, and mechanically ventilated in the volume control mode (Evita Infinity-V500—Drager—Italy Spa or Servo-U Maquet Medical System, Wayne, NJ, USA). We ascertained the absence of spontaneous breathing activity by evaluating the flow/pressure curves displayed on the ventilator screen. Tidal volume was set at 6 mL/kg of predicted body weight (PBW).

We measured CI using transpulmonary thermodilution (TPTD) (EV1000™/Volume View Edwards Lifesciences Corporation, Irvine, CA 92614). CI and the other hemodynamic variables derived from pulse contour analysis were recorded over 20 secs [21]. Before each measurement, we calibrated our system by injecting at least three 15-mL boluses of cold (4 °C) saline. We averaged the three measures only if none had a difference greater than 20% of the mean value [21].

EEOt consisted of a prolonged expiratory pause (20 s) in which no expiratory or inspiratory efforts were recorded.

Fluid responsiveness was defined as an increase in CI of more than 15% after a standardized fluid challenge (500 mL of Ringer’s lactate in 10 min).

Fluid responders were tested more than once, at least 12 h apart, if they met the inclusion criteria again. Each EEOt was considered a single and independent measure.

The following protocol describes our procedure in detail (Fig. 1).

Fig. 1
figure 1

Study design

T1 (baseline 1): we performed the first set of TPTD to assess the CI, the SVI, the stroke volume variation (SVV), and the systemic vascular resistance index (SVRI). We also recorded heart rate (HR), mean arterial pressure (MAP), and central venous pressure (CVP). Simultaneously, we measured the CDPV and the cFT using carotid Doppler (see below).

T2 (EEOt): one operator applied a 20-s EEOt and measured the hemodynamic variables using the pulse contour method, while a second operator performed a carotid Doppler and recorded CDPV and cFT during the last five cardiac cycles before the end of EEOt.

T3 (baseline 2): we visually verified that the hemodynamic values had returned to the baseline before administering the fluid challenge.

T4 (fluid challenge): the patients received a 500-mL bolus of Ringer’s lactate solution in 10 min. After completing the fluid challenge, we performed the last series of hemodynamic measurements, including CI, MAP, HR, SVI, CVP, SVRI, and carotid Doppler, as above.

Two operators collected the hemodynamic variables manually and kept a screenshot of the measurements as a record for data check. Catecholamine infusion, mechanical ventilation settings, and bed position were kept constant at all times.

Carotid Doppler

One investigator (SD'A) with previous formal training in critical care ultrasound insonated the common carotid artery in a longitudinal view approximately 1–2 cm before the bifurcation using a 5–10-MHz linear array transducer (Vivid™ iq, General Electric Healthcare, Chicago, Illinois, USA) and performed a pulse-wave Doppler analysis. The sample volume was in the vessel’s middle, with the caliper positioned parallel to flow, angled at no more than 60°. We averaged five consecutive measurements to limit the effects of respiratory-induced changes in CDPV and cFT.

The ΔCDPV was expressed as a percentage and was calculated with the following formula:

$$\left( {{\text{average}}\;{\text{CDPV}}_{{{\text{post}}}} {-}{\text{ average}}\;{\text{CDPV}}_{{{\text{pre}}}} /{\text{ average}}\;{\text{CDPV}}_{{{\text{pre}}}} } \right)*{1}00$$

where CDPVpre values refer to the Baseline 1 and the CPDVpost values refer to those obtained during EEOt or after fluid challenge.

The FT was measured from the beginning of the flow tracing’s upstroke to the nadir of its dicrotic notch on a pulse waveform analysis. We used the Wodey’s formula: cFT = FT + 1.29*(HR-60) to correct measurements for the heart rate [22]. We measured the ΔcFT using the same formula we used for ΔCDPV.

Study endpoints

The primary endpoint of this study was the correlation between changes in CDPV and CI during an EEOt. Secondary endpoints were the correlations between changes in CDPV and CI after the fluid challenge and between changes in cFT and CI during EEOt and after fluid challenge. We also explored the ability of changes in CDPV and cFT during EEOt to predict fluid responsiveness. Differences between responders and non-responders were studied during all three phases of our observation (baseline, EEOt, and fluid challenge).

Statistical analysis

The distribution of continuous variables was assessed with the Kolmogorov–Smirnov test. Data are expressed as mean ± standard deviation (SD) or median (interquartile range), as appropriate. Categorical variables are reported as fractions and percentages (%). Differences between parametric variables were evaluated with the Student’s t test for unpaired and paired measures or with the Mann–Whitney and Wilcoxon tests, as appropriate. Fisher’s exact test was adopted for categorical variables. LSD and Scheffé’s test were used to correct for multiple comparisons.

We used two-way ANOVA to detect significant variable changes across time points between two groups. We calculated a receiving-operator characteristic (ROC) curve using the Wilson–Brown method to summarize the ability of each measure to predict fluid responsiveness across the various thresholds. For all predictors, we identified the optimal threshold based on the Youden index J (J = sensitivity + specificity − 1).

Sample size calculation for the primary outcome was made considering a correlation between CDPV changes and CI changes during EEOt of 0.8 with a null hypothesis of correlation set at 0.5. With beta error at 0.8 and a two-sided alfa error of 0.05, 38 measurements were needed to test the study hypothesis. For the area under the ROC curve (AUROC), we considered an AUROC of 0.75, a null hypothesis of 0.5, and beta and alpha error as above. The total required sample was 40 measurements.

For the carotid Doppler variables, we calculated how many measurements fell within the gray zone, i.e., the number of cases with a sensitivity < 90% and/or a specificity < 90%.

We also estimated the precision and the least significant change (LSC) [23] of CDPV. Each velocity was measured five consecutive times in each patient.

Precision was estimated as

$${2}\;{\text{SD}}/{\text{mean}}/{\text{sqrt}}\;{(}n{)}$$

where SD is the standard deviation of the measurements, and n is the number of measurements, based on the formula described by Cecconi et al. [24]

The LSC was calculated as

$${\text{precision}}*{\text{sqrt}}\;{(2)}$$

and expressed as a percentage. We performed the repeated measures correlation (rmcorr) [25] between the percentage changes in CI vs. the percentage changes in CDPV or cFT during EEOt and the percentage changes in CI vs. the percentage changes in CDPV or cFT after the fluid challenge. We stratified the results of the rmcorr for responders and non-responders. Finally, to assess the concordance between the changes of Doppler variables and the corresponding changes of CI we calculated four-quadrant clinical concordance plots [26]. In these graphs, we plotted the measurements where the changes of CDPV or cFT and the changes of CI, both expressed as a percentage, had the same direction and the same extent. These changes were divided into three categories, non-significant change (ΔCI ± 5% or less); moderate change (ΔCI ± 5–15%); or large change (ΔCI ± 15% or more). We plotted the Doppler/CI concordance during the EEOt and the fluid challenge. In addition, to illustrate the predictive ability of Doppler variables, we plotted their percentage changes at EEOt vs. the changes in CI after the fluid challenge.

We used SPSS® 28 software (IBM Chicago IL), MedCalc® Statistical Software version 20.210 (MedCalc Software Ltd, Ostend, Belgium; https://www.medcalc.org; 2022), and the rmcorr R package (https://cran.r-project.org/web/packages/rmcorr/) for statistical analysis.

Results

We performed 44 measurements on 18 patients. Their characteristics are shown in Table 1. At inclusion, all patients were in septic shock [27] and were sedated and ventilated in volume control mode using lung-protective ventilation (mean tidal volume 6 ± 0.5 mL/kg).

Table 1 Patient characteristics

The overall rate of fluid responsiveness was 43.2% (19 out of 44 measures).

Baseline

At baseline, fluid responders had a significantly lower CI (2.2 ± 0.6 vs. 2.8 ± 0.9 L/min/m2; p = 0.012) and a higher SVV (13.7 ± 6.4 vs. 10.0 ± 3.4%; p = 0.029) than non-responders. There were no significant differences in HR, MAP, CVP, and SVRI. Fluid responders also had a significantly lower CDPV (88.1 ± 24.6 vs. 111.2 ± 37.5 cm/s, p = 0.019) and cFT (266.3 ± 31.0 vs. 285.1 ± 24.7 ms, p = 0.037) than non-responders (Table 2).

Table 2 Hemodynamic variables at baseline, during EEOt and after fluid challenge in responders (n = 19) and non-responders (n = 25)

Hemodynamic effects of EEOt

During the EEOt, the CI increased by 10.9% (from 2.2 ± 0.6 to 2.5 ± 0.8 L/min/m2; p < 0.001) and the CDPV increased by 10.5% (from 88.1 ± 24.6 to 100 ± 34.5 cm/s; p < 0.05) in responders, while no significant change was observed in non-responders (Table 2 and Figs. 2, 3). The cFT showed a smaller increase that did not significantly differ between responders and non-responders (Table 2 and Additional file 1: Figure E1).

Fig. 2
figure 2

Changes in cardiac index in responders (FR) and non-responders (NFR) during EEOt and after fluid challenge

Fig. 3
figure 3

Changes in carotid Doppler peak velocity (CDPV) in responders (FR) and non-responders (NFR) during EEOt and after fluid challenge

Hemodynamic effects of fluid challenge

After the 500-mL fluid challenge, in fluid responders, the CI increased by 22.2% (from 2.2 ± 0.6 to 2.8 ± 0.9 L/min/m2; p < 0.05) and the CDPV increased by 19.6% (from 88.1 ± 24.6 to 108 ± 35.4 cm/s; p = 0.002), while no significant change was observed in non-responders (Table 2 and Figs. 2, 3). The cFT showed a larger increase from the baseline after the fluid challenge than during the EEOt. However, this increase did not significantly differ between responders and non-responders (Table 2 and Additional file 1: Figure E1).

The mean values of MAP, HR, SVV, CVP, and SVRI did not change significantly during EEOt and after the fluid challenge.

Correlation between changes in carotid Doppler and in cardiac output measurements

The linear correlation coefficient r between the percentage changes in CDPV and CI during EEOt was 0.52 [0.26–0.71]. A significant but lower correlation was found for cFT (r = 0.35 [0.06–0.58]) (Additional file 1: Figure E2).

On rmcorr, the percentage changes in CDPV vs. the percentage changes in CI were significantly correlated across EEOt and fluid challenge in responders (r = 0.405 [0.046–0.733]), while no significant correlation was found in non-responders (r = 0.268 [− 0.147–0.600]; Additional file 1: Figure E3). Similar results were observed with cFT (r = 0.628 [0.257–0.838] and 0.148 [− 0.262–0.520], respectively; Additional file 1: Figure E4).

The clinical concordance plot showed that the overall fraction of concordant changes (CDPV or cFT vs. CI) was greater for cFT than for CDPV at EEOt (Additional file 1: Figure E5 A). However, the number of concordant changes above 5% was proportionally higher for CDPV. This difference was more evident in measurements performed after the fluid challenge and when comparing changes in Doppler variables at EEOt vs. changes in CI at the fluid challenge (Additional file 1: Figure E5 B–C).

Prediction of fluid responsiveness

During EEOt, an increase in CI ≥ 5.35% predicted fluid responsiveness with 91.7% specificity and 78.9% sensitivity. The AUROC of CI was 0.852 (95% CI 0.727–0.977, p = 0.0001) (Fig. 4A).

Fig. 4
figure 4

A, B ROC curves of EEOt-induced changes in CI (A) and CDPV (B) for predicting fluid responsiveness

The LSC of carotid Doppler measures in our population was 7.4% for CDPV and 3.5% for cFT. An increase in CDPV ≥ 10.5% during EEOt predicted fluid responsiveness with 96.2% specificity (95% CI 80.0–99.8) and 53.0% sensitivity (95% CI 32.1–73.3), with an AUROC of 0.743 (95% CI 0.580–0.906, p = 0.006) (Fig. 4B). Sixty-one percent of measurements fell within the gray zone (CDPV ranging from − 13.5 and 9.5 cm/s). The cFT changes during EEOt did not accurately predict fluid responsiveness (AUROC 0.655 [0.496 to 0.791], p = 0.07; Additional file 1: Figure E6).

Discussion

Our results showed a significant correlation between changes in CPDV during EEOt and changes in CI during the subsequent fluid challenge. An increase in CDPV greater than 10.5% during an EEOt predicted fluid responsiveness in ICU patients with septic shock with high specificity. This may allow clinicians to non-invasively identify about 40% of fluid responders and safely administer them fluids without risking a fluid overload.

The carotid artery Doppler assessment of fluid responsiveness coupled with an EEOt can be performed in mechanically ventilated patients in whom continuous cardiac monitoring is unavailable or the transthoracic echocardiographic windows are technically impaired. These conditions may be common not only in the ICU, but also in the operating room in patients undergoing major surgery whose chest wall is inaccessible to echocardiography. In this setting, the carotid artery might be the only accessible large-size arterial vessel for performing arterial Doppler. The position of the carotid artery, which is located just distally to the aortic outflow tract, makes its flow a good approximation of the aortic flow [28]. Carotid Doppler does not suffer from the technical limitations of echocardiography, where measurement of left ventricular outflow tract velocities for the estimation of SV requires specific training for adequate performance, and it is not easily obtainable, especially in ventilated patients.

To the best of our knowledge, this is the first study assessing fluid responsiveness using the carotid Doppler variations in association with an EEOt in critically ill patients. The potential usefulness of the changes in carotid Doppler during EEOt has been previously investigated in healthy volunteers [28]. The authors found a good correlation between changes in carotid VTI and aortic VTI (ρ = 0.79) or SV (ρ = 0.95). However, the results of that study are not directly applicable to the critical care setting. Moreover, that study used a different carotid Doppler equipment (wearable device) and evaluated a different index (changes in carotid VTI pattern) compared to our study.

Two studies [18, 19] investigated the accuracy of changes in carotid Doppler induced by intrathoracic pressure variation during lung-protective mechanical ventilation with low tidal volume (6 mL/kg of PBW). One study [18] measured CDPV in patients undergoing elective coronary artery bypass surgery, while the other study measured CDPV in patients with septic shock in the ICU [19]. In these studies, the AUROC of CDPV was 0.85 [0.72–0.97] and 0.88 [0.77–0.95], respectively, which is greater than the 0.74 value we found in our study. These measurements, however, were made during the respiratory cycle. Conversely, we investigated the changes between CDPV before and during the EEO maneuver.

EEOt and fluid challenge were not consistently associated with increased Doppler velocity. Namely, CDPV decreased in a minority of responders (3/19 measurements during the EEOt and 2/19 measurements after the fluid challenge) and almost half of the non-responders (11/25 measurements at either time point; Additional file 1: Figure E7). During the EEOt, the CDPV percentage decrease was below the LSC in all but five measurements (two in responders and three in non-responders). In non-responders, the CDPV changes were symmetrically distributed in both directions, which suggests a random variation. The reason for the occasional CDPV decrease we observed in fluid responders is unclear, but a patient-specific bias cannot be excluded since all the relevant measurements were obtained from a single patient.

Results of the repeated measures correlation clearly showed that the changes in CDPV and cFT both during EEOt and after fluid challenge were correlated with the parallel changes in CI or SVI in responders. This is consistent with the ability of EEOt-induced changes in CPDV to predict fluid responsiveness in our study. However, the accuracy of CDPV was lower than that of other indices, such as PLR. In fact, the gray zone of CPDV was 61%, meaning that only the CDPV values included in the remaining 39% range were sufficiently accurate to make a clinical decision. A possible explanation for this finding may be that the EEOt causes smaller changes in venous return compared to the PLR. The PLR in fact causes a rapid displacement of a high volume (about 300 mL) of venous blood from the lower body toward the right heart, mimicking an entire fluid challenge [29]. Another explanation is that we measured CDPV and CI during slightly different time windows. While the five carotid Doppler curves were recorded during the last seconds of the EEOt, when the maneuver’s effect was maximal, the SVI and CI were calculated over a 20-s time window that only partially coincided with the last seconds of the end-occlusion. A further explanation could be that the lung-protective ventilation strategy we adopted (tidal volume 6 mL/kg) may have reduced the hemodynamic impact of EEOt. However, while some studies showed a greater diagnostic accuracy of the EEOt at 8 mL/kg vs. 6 mL/kg of PBW [7, 8], other studies showed a high accuracy of EEOt at a tidal volume of 6–7 mL/kg of PBW [16, 30, 31]. In addition, a recent systematic review and meta-analysis [32] showed no significant difference between the accuracies of EEOt in studies where the tidal volume was ≤ 7 mL/kg and those using higher tidal volumes (summary AUROC 0.96 [0.92–0.97] vs. 0.89 [0.82–0.95], respectively; p = 0.44). Regarding PEEP, one study showed that PEEP levels ranging from 5 to 14 cmH2O do not affect the predictive ability of the EEOt [14]. The overall evidence suggests that ventilator settings are unlikely to affect the accuracy of EEOt.

The clinical concordance analysis of the percentage changes in Doppler variables vs. the percentage changes in CI showed that many of the concordant changes in cFT were ± 5% or less. Compared to cFT, CDPV had a greater proportion of clinically significant concordant changes (5–15% or > 15%; categories 2 and 3 in Additional file 1: Figure E5) [26]. This was evident especially when comparing the changes in Doppler variables at EEOt with the CI changes after the fluid challenge and is consistent with the greater ability of CDPV changes to predict fluid responsiveness.

Despite a clear correlation between cFT and CI changes at EEOt and fluid challenge, cFT did not show a significant predictive ability for fluid responsiveness in our study. The reasons for this are unclear and deserve further investigation. Since the LSC of cFT was only about half the percentage increase in cFT during EEOt or after the fluid challenge in fluid responders, this result does not seem to be due to an insufficient precision of the Doppler technique. Because of the small AUROC of cFT, our study was not powered enough to assess its predictive ability with confidence.

In our study, we defined fluid responsiveness as a ≥ 15% increase in CI. This choice was based on previous literature on EEOt. However, an SVI increase could have been an equally valuable target [18,19,20]. Carotid Doppler surrogates are more physiologically related to stroke volume than cardiac output. Moreover, stroke volume is the closest clinically available approximation of the cardiac length–tension relationship, which makes it very suitable for evaluating fluid responsiveness [33].

We may have considered adding an end-inspiratory to the end-inspiratory occlusion maneuver for predicting fluid responsiveness. In a study by Jozwiak et al. [16], the diagnostic threshold of this maneuver was 13%, higher than the 10% LSC of VTI used in that study. However, the LSC of CPDV and cFT we used in our study was lower, 7.4% and 3.5%, respectively. Both were lower than the 10.5% diagnostic threshold we found, which makes the need for adding an end-inspiratory occlusion test less stringent.

Fluid responsiveness depends on the slope of the Frank–Starling curve, which is critically affected by cardiac contractility. In our study, we excluded patients with cardiac failure, so that the role of cardiac contractility was not specifically assessed. However, previous observations made using aortic Doppler [34] have shown that CDPV is directly correlated with cardiac inotropy, while cFT is inversely correlated with systemic vascular resistance (r2 = 0.66). Carotid Doppler could therefore be used to investigate the relationship between cardiac contractility and vascular resistance in response to therapy, assuming that CDPV measurement is accurate and that blood flow in the supra-aortic vessels mirrors the blood flow in the thoracic aorta.

Some limitations of our study must be acknowledged. Firstly, this study was conducted on adult patients with septic shock in controlled ventilation with 6 mL/kg of PBW with absent or minimal spontaneous breathing, and its findings are not necessarily generalizable to other patient populations. Secondly, this technique is based on manual detection and—as such—is prone to intra-observer variation. In our study, all carotid Doppler measurements were made by a single experienced operator. While this was essential to ensure the reproducibility of our measurements, it may have overestimated their precision and reduced the external validity of our findings. Thirdly, we used the EV1000™/Volume View device, which calculates SVI and CI on the average pulse contour recorded over 20 s. Inevitably, this time window only partially overlapped with those of the EEOt, which may have affected the accuracy of our findings. Fourthly, as specified in our Methods, we compared both the hemodynamic measurements made during EEOt and those made after the fluid challenge with the first baseline (T1), since on T3 the return to the baseline after the EEOt was assessed only visually. Although the effect of the EEOt is assumed to be transient, we cannot exclude that some residual effects may have persisted after the end of EEOt and have reduced the accuracy of the subsequent measurements. Fifthly, the 61% gray zone we found in our study suggests caution when using Doppler results to make clinical decisions. Lastly, carotid Doppler might be less accurate in patients affected by arrhythmias, such as atrial fibrillation, which are common in septic shock patients [35], or by valvular disorders, severe heart failure, carotid stenosis > 50% or in some surgical settings such as brain or neck surgery.

Conclusions

Our study showed that in adult patients with septic shock, the changes in CPDV and cFT during EEOt on carotid Doppler are correlated with the changes in CI that occur after a fluid challenge, and that an increase in CDPV greater than 10.5% during a 20-s EEOt predicted fluid responsiveness with > 95% specificity. Carotid Doppler can be used to assess fluid responsiveness in patients who are sedated and mechanically ventilated and without arrhythmias, when invasive hemodynamic monitoring is not immediately available. However, its large gray zone is an important limitation.

Availability of data and materials

All data generated or analyzed during this study are included in this article. The dataset used and/or analyzed during the study is available from the corresponding author on request.

Abbreviations

cFT:

Corrected flow time

CI:

Cardiac index

CDPV:

Carotid Doppler peak velocity

CIs:

Confidence intervals

CVP:

Central venous pressure

ELWI:

Extravascular lung water index

EEOt:

End-expiratory occlusion test

FHT:

Functional hemodynamic tests

GEDVI:

Global end-diastolic volume index

HR:

Heart rate

ICU:

Intensive care unit

MAP:

Mean arterial pressure

PLR:

Passive leg raising

rmcorr:

Repeated measures correlation

SV:

Stroke volume

SVI:

Stroke volume index

SVRI:

Systemic vascular resistance index

SVV:

Stroke volume variation

TPTD:

Trans-pulmonary thermodilution

TTE:

Trans-thoracic echocardiography

VTI:

Velocity–time integral

References

  1. Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, Jaeschke R, Mebazaa A, Pinsky MR, Teboul JL, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40(12):1795–815.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med. 2011;39(2):259–65.

    Article  PubMed  Google Scholar 

  3. Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, et al. Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med. 2015;41(9):1529–37.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, Saderi L, Sotgiu G, Antonelli M, Cecconi M. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care (London, England). 2019;23(1):264.

    Article  Google Scholar 

  5. Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34(5):1402–7.

    Article  PubMed  Google Scholar 

  6. Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36(9):1475–83.

    Article  PubMed  Google Scholar 

  7. Myatra SN, Prabu NR, Divatia JV, Monnet X, Kulkarni AP, Teboul JL. The changes in pulse pressure variation or stroke volume variation after a “tidal volume challenge” reliably predict fluid responsiveness during low tidal volume ventilation. Crit Care Med. 2017;45(3):415–21.

    Article  PubMed  Google Scholar 

  8. Messina A, Montagnini C, Cammarota G, De Rosa S, Giuliani F, Muratore L, Della Corte F, Navalesi P, Cecconi M. Tidal volume challenge to predict fluid responsiveness in the operating room: an observational study. Eur J Anaesthesiol. 2019;36(8):583–91.

    Article  PubMed  Google Scholar 

  9. Biais M, Lanchon R, Sesay M, Le Gall L, Pereira B, Futier E, Nouette-Gaulain K. Changes in Stroke volume induced by lung recruitment maneuver predict fluid responsiveness in mechanically ventilated patients in the operating room. Anesthesiology. 2017;126(2):260–7.

    Article  PubMed  Google Scholar 

  10. Messina A, Colombo D, Barra FL, Cammarota G, De Mattei G, Longhini F, Romagnoli S, DellaCorte F, De Backer D, Cecconi M, et al. Sigh maneuver to enhance assessment of fluid responsiveness during pressure support ventilation. Crit Care (London, England). 2019;23(1):31.

    Article  Google Scholar 

  11. Monnet X, Osman D, Ridel C, Lamia B, Richard C, Teboul JL. Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med. 2009;37(3):951–6.

    Article  PubMed  Google Scholar 

  12. Gavelli F, Teboul JL, Monnet X. The end-expiratory occlusion test: please, let me hold your breath! Crit Care (London, England). 2019;23(1):274.

    Article  Google Scholar 

  13. Monnet X, Bleibtreu A, Ferre A, Dres M, Gharbi R, Richard C, Teboul JL. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012;40(1):152–7.

    Article  PubMed  Google Scholar 

  14. Silva S, Jozwiak M, Teboul JL, Persichini R, Richard C, Monnet X. End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome. Crit Care Med. 2013;41(7):1692–701.

    Article  PubMed  Google Scholar 

  15. Yonis H, Bitker L, Aublanc M, Perinel Ragey S, Riad Z, Lissonde F, Louf-Durier A, Debord S, Gobert F, Tapponnier R, et al. Change in cardiac output during Trendelenburg maneuver is a reliable predictor of fluid responsiveness in patients with acute respiratory distress syndrome in the prone position under protective ventilation. Crit Care (London, England). 2017;21(1):295.

    Article  Google Scholar 

  16. Jozwiak M, Depret F, Teboul JL, Alphonsine JE, Lai C, Richard C, Monnet X. Predicting fluid responsiveness in critically ill patients by using combined end-expiratory and end-inspiratory occlusions with echocardiography. Crit Care Med. 2017;45(11):e1131–8.

    Article  PubMed  Google Scholar 

  17. Georges D, de Courson H, Lanchon R, Sesay M, Nouette-Gaulain K, Biais M. End-expiratory occlusion maneuver to predict fluid responsiveness in the intensive care unit: an echocardiographic study. Crit Care (London, England). 2018;22(1):32.

    Article  Google Scholar 

  18. Song Y, Kwak YL, Song JW, Kim YJ, Shim JK. Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. Br J Anaesth. 2014;113(1):61–6.

    Article  CAS  PubMed  Google Scholar 

  19. Ibarra-Estrada MA, Lopez-Pulgarin JA, Mijangos-Mendez JC, Diaz-Gomez JL, Aguirre-Avalos G. Respiratory variation in carotid peak systolic velocity predicts volume responsiveness in mechanically ventilated patients with septic shock: a prospective cohort study. Crit Ultrasound J. 2015;7(1):29.

    Article  PubMed  Google Scholar 

  20. Kimura A, Suehiro K, Juri T, Tanaka K, Mori T. Changes in corrected carotid flow time induced by recruitment maneuver predict fluid responsiveness in patients undergoing general anesthesia. J Clin Monit Comput. 2021;8:1–9.

    Google Scholar 

  21. Kiefer N, Hofer CK, Marx G, Geisen M, Giraud R, Siegenthaler N, Hoeft A, Bendjelid K, Rex S. Clinical validation of a new thermodilution system for the assessment of cardiac output and volumetric parameters. Crit Care (London, England). 2012;16(3):R98.

    Article  Google Scholar 

  22. Wodey E, Carre F, Beneux X, Schaffuser A, Ecoffey C. Limits of corrected flow time to monitor hemodynamic status in children. J Clin Monit Comput. 2000;16(3):223–8.

    Article  CAS  PubMed  Google Scholar 

  23. Jozwiak M, Mercado P, Teboul JL, Benmalek A, Gimenez J, Dépret F, Richard C, Monnet X. What is the lowest change in cardiac output that transthoracic echocardiography can detect? Crit Care (London, England). 2019;23(1):116.

    Article  Google Scholar 

  24. Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies—with specific reference to the measurement of cardiac output. Crit Care (London, England). 2009;13(1):201.

    Article  Google Scholar 

  25. Bakdash JZ, Marusich LR. Repeated measures correlation. Front Psychol. 2017;8:456.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Montenij LJ, Buhre WF, Jansen JR, Kruitwagen CL, de Waal EE. Methodology of method comparison studies evaluating the validity of cardiac output monitors: a stepwise approach and checklist. Br J Anaesth. 2016;116(6):750–8.

    Article  CAS  PubMed  Google Scholar 

  27. Singer M, Deutschman CS, Seymour CW, Shankar-Hari M, Annane D, Bauer M, Bellomo R, Bernard GR, Chiche JD, Coopersmith CM, et al. The third international consensus definitions for sepsis and septic shock (sepsis-3). JAMA. 2016;315(8):801–10.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  28. Kenny JS, Barjaktarevic I, Eibl AM, Parrotta M, Long BF, Eibl JK. A wearable carotid Doppler tracks changes in the descending aorta and stroke volume induced by end-inspiratory and end-expiratory occlusion: a pilot study. Health Sci Rep. 2020;3(4): e190.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Monnet X, Teboul JL. Passive leg raising: five rules, not a drop of fluid! Crit Care (London, England). 2015;19(1):18.

    Article  Google Scholar 

  30. Biais M, Larghi M, Henriot J, de Courson H, Sesay M, Nouette-Gaulain K. End-expiratory occlusion test predicts fluid responsiveness in patients with protective ventilation in the operating room. Anesth Analg. 2017;125(6):1889–95.

    Article  PubMed  Google Scholar 

  31. Dépret F, Jozwiak M, Teboul JL, Alphonsine JE, Richard C, Monnet X. Esophageal Doppler can predict fluid responsiveness through end-expiratory and end-inspiratory occlusion tests. Crit Care Med. 2019;47(2):e96–102.

    Article  PubMed  Google Scholar 

  32. Gavelli F, Shi R, Teboul JL, Azzolina D, Monnet X. The end-expiratory occlusion test for detecting preload responsiveness: a systematic review and meta-analysis. Ann Intensive Care. 2020;10(1):65.

    Article  PubMed  PubMed Central  Google Scholar 

  33. Kenny JS, Barjaktarevic I. Letter to the Editor: Stroke volume is the key measure of fluid responsiveness. Crit Care (London, England). 2021;25(1):104.

    Article  Google Scholar 

  34. Singer M, Allen MJ, Webb AR, Bennett ED. Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med. 1991;19(9):1138–45.

    Article  CAS  PubMed  Google Scholar 

  35. Meierhenrich R, Steinhilber E, Eggermann C, Weiss M, Voglic S, Bögelein D, Gauss A, Georgieff M, Stahl W. Incidence and prognostic impact of new-onset atrial fibrillation in patients with septic shock: a prospective observational study. Crit Care (London, England). 2010;14(3):R108.

    Article  Google Scholar 

Download references

Funding

This study was funded by a finalized grant from Università Cattolica del Sacro Cuore Linea D1/2018.

Author information

Authors and Affiliations

Authors

Contributions

SD'A, AMD, and CS contributed to conception and design of the work. SD'A, AMD, SC, and CP were involved in enrollment and data acquisition. CS, SD'A, AMD, and AM contributed to interpretation of data. SD'A, CS, AMD, and AM were involved in manuscript writing. CS and MA contributed to revision and senior contribution. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Claudio Sandroni.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the institutional review board (Prot. N. 0048329/18 ID 1677) of the Fondazione Policlinico Universitario A. Gemelli- IRCCS and carried out in accordance with the principles outlined in the Declaration of Helsinki. All patients or their legal representatives gave their written informed consent to participate.

Consent to publication

Not applicable.

Competing interests

On behalf of all authors, the corresponding author states that there is no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1

. Supplementary figures.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

D’Arrigo, S., Dell’Anna, A.M., Sandroni, C. et al. Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?. Crit Care 27, 153 (2023). https://doi.org/10.1186/s13054-023-04422-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13054-023-04422-9

Keywords