Presentation + Paper
20 July 2018 The spectral response of X-ray CCDs in the energy band around Si-K edge: a solution to the Si-K edge problem for the XIS onboard Suzaku
Author Affiliations +
Abstract
X-ray Imaging Spectrometers (XIS) are the X-ray CCD cameras onboard Suzaku. They were operated in orbit from 2005 to 2015 and produced lots of findings with their good energy resolution and low non X-rat background. Precise calibration including the 10 eV accuracy in the energy scale reinforced them. Nevertheless, there has been a unresolved calibration issue in the spectral response around the Si-K edge (1.839 keV) appearing as systematic residuals up to 10%. The residual is negative peaking at 1.85 keV in the front illuminated (FI) sensors and positive peaking at 1.8 keV in the back illuminated (BI) sensor for X-ray sources dominated by continuum X-ray emission. Various attempts to eliminate these residuals by changing response parameters or quantum efficiency models have been insufficient. In this paper, we revisit this problem by focusing on the relation between incident X-ray energy and pulse height. We introduce a jump in that relation at the Si-K edge by modifying the , and optimize its value so as to minimize the residuals in the fit of the X-ray spectra for the black hole binary LMC X-3, a source dominated by continuum emission. We find the introduction of a jump significantly reduces the residuals. The optimized jump values are +4:2 channel, +4:0 channel, and -3:1 channel, corresponding to 15.3 eV, -11:3 eV, and 14.6 eV, for XIS0, XIS3 (FI), and XIS1 (BI), respectively. The direction of the jump is opposite for the FI and for the BI. We revise the response matrices generator so as to include the jump for each XIS sensor, and apply it to the X-ray spectra of the Perseus cluster of galaxies which has various emission lines in the spectra, and the blazar PKS2155-304 which was observed various epoch in the Suzakuoperation. We confirm the residuals are significantly reduced for these sources, too. We finally suggest the jump at Si-K edge in the energy and pulse height relation is qualitatively explained, if some of charges are lost in course of charger collection to the electrode of the CCD in the depletion later, and its amount is large for larger travel length in the depletion layer. If this explanation is correct, the Si-K edge problem and its solution presented in this paper is not specific only for the SuzakuXIS but also for other X-ray CCDs.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Koki Okazaki, Kiyoshi Hayashida, Hiroshi Nakajima, Riku Shomura, Tomokage Yoneyama, Hironori Matsumoto, Hiroshi Tsunemi, Koji Mori, Masahiro Tsujimoto, Yoshitomo Maeda, and Ken Ebisawa "The spectral response of X-ray CCDs in the energy band around Si-K edge: a solution to the Si-K edge problem for the XIS onboard Suzaku", Proc. SPIE 10709, High Energy, Optical, and Infrared Detectors for Astronomy VIII, 107091F (20 July 2018); https://doi.org/10.1117/12.2314259
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Calibration

Matrices

Charge-coupled devices

Sensors

Quantum efficiency

X-ray imaging

RELATED CONTENT

Testing fully depleted CCD
Proceedings of SPIE (July 28 2014)
Soft x ray response of x ray CCD camera XIS...
Proceedings of SPIE (October 11 2004)
Ground calibration of the XMM EPIC MOS cameras at the...
Proceedings of SPIE (October 22 1999)
Performance Characteristics Of CCD's For The Acis Experiment
Proceedings of SPIE (December 21 1988)
Characterisation Of Fully Depleted Pn-CCD's For X-Ray Imaging
Proceedings of SPIE (November 27 1989)

Back to Top