Effect of Specimen Size and Aspect Ratio on the Tensile Properties of Porcine Aortic Valve Tissues

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

The measurement of mechanical properties of biological tissues is subject to artifacts such as natural variability and inconsistency in specimen preparation. As a result, data cannot be easily compared across laboratories. To test the effects of variable specimen dimensions, we systematically modified the size and aspect ratio (AR) of porcine aortic valve tissues and measured their stiffness and extensibility. We found that: (i) as the AR of circumferential specimens increased from 1:1 to 5:1, their stiffness increased by 36% (p < 0.001) and their extensibility decreased by 21% (p < 0.001); (ii) as the AR of radial specimens increased from 0.8:1 to 4:1, their stiffness increased by 36% (p < 0.001) and their extensibility decreased by 34% (p < 0.001); (iii) as the size of circumferential specimens was reduced from 128 to 32 mm2 at fixed AR (2:1), their stiffness decreased by 6% (p=0.05), and their extensibility increased by 17% (p < 0.001); and (iv) as the size of radial specimens was reduced from 72 to 32 mm2 at fixed AR (2:1), their stiffness decreased by 7% (p=0.03) and their extensibility increased by 16% (p=0.005). Thus, as specimens of constant length became narrower, they became stiffer and less extensible, and as specimens of fixed aspect ratio became smaller, they became less stiff and more extensible. Statistical models of these trends were predictive and can thus be used to integrate materials test data across different laboratories. © 2003 Biomedical Engineering Society.

PAC2003: 8719Rr, 8715La, 8710+e

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Atkinson, T. S., B. J. Ewers, and R. C. Haut. The tensile and stress relaxation responses of human patellar tendon varies with specimen cross-sectional area. J. Biomech.32:907–914, 1999.

    Google Scholar 

  2. Carew, E. O., J. E. Barber, and I. Vesely. Role of preconditioning and recovery time in repeated testing of aortic valve tissues: Validation through quasilinear viscoelastic theory. Ann. Biomed. Eng.28:1093–1100, 2000.

    Google Scholar 

  3. Carew, E. O., and I. Vesely. A new method of estimating gauge length for porcine aortic valve test specimens. (in press).

  4. Clark, R. E., and E. H. Finke. Scanning and light microscopy of human aortic leaflets in stressed and relaxed states. J. Thorac. Cardiovasc. Surg.67:792–804, 1974.

    Google Scholar 

  5. David, H., D. R. Boughner, I. Vesely, and G. Gerosa. The pulmonary valve: Is it mechanically suitable for use as an aortic valve replacement?ASAIO J.40:206–212, 1994.

    Google Scholar 

  6. Diggle, D. J., K. Y. Liang, and S. L. Zegler. Analysis of Longitudinal Data. Oxford, NY: Oxford Science, 1994.

    Google Scholar 

  7. Haut, R. C., and R. W. Little. A constitutive equation for collagen fibers. J. Biomech.5:423–430, 1972.

    Google Scholar 

  8. Lee, J. M., D. W. Courtman, and D. R. Boughner. The glutaraldehyde-stabilized porcine aortic valve xenograft. I. Tensile viscoelastic properties of the fresh leaflet material. J. Biomed. Mater. Res.18:61–77, 1984.

    Google Scholar 

  9. Lee, J. M., S. A. Haberer, C. A. Pereira, W. A. Naimark, D. W. Courtman, and G. J. Wilson. High strain rate testing and structural analysis of pericardial bioprosthetic materials. In: Biomaterials' Mechanical Properties ASTM STP 1173, edited by H. E. Kambic and A. T. Yakabori, Philadelphia: ASTM, 1994, pp. 19–42.

    Google Scholar 

  10. Leeson-Dietrich, J., D. R. Boughner, and I. Vesely. Porcine pulmonary and aortic valves: A comparison of their tensile viscoelastic properties at physiological strain rates. J. Heart Valve Dis.4:88–94, 1995.

    Google Scholar 

  11. Rousseau, E. P., A. A. Sauren, M. C. van Hout, and A. A. van Steenhoven. Elastic and viscoelastic material behaviour of fresh and glutaraldehyde-treated porcine aortic valve tissue. J. Biomech.16:339–348, 1983.

    Google Scholar 

  12. Sauren, A. A., W. Kuijpers, A. A. van Steenhoven, and F. E. Veldpaus. Aortic valve histology and its relation with mechanics-preliminary report. J. Biomech.13:97–104, 1980.

    Google Scholar 

  13. Schoen, F. J.Aortic valve structure-function correlations: Role of elastic fibers no longer a stretch of the imagination. J. Heart Valve Dis.6:1–6, 1997.

    Google Scholar 

  14. Schoen, F. J.Future directions in tissue heart valves: Impact of recent insights from biology and pathology. J. Heart Valve Dis.8:350–358, 1999.

    Google Scholar 

  15. Tan, A. J., and D. L. Holt. The effects of sterilization and storage treatments on the stress–strain behavior of aortic valve leaflets. Ann. Thorac. Surg.22:188–194, 1976.

    Google Scholar 

  16. van Noort, R., S. P. Yates, T. R. Martin, A. T. Barker, and M. M. Black. A study of the effects of glutaraldehyde and formaldehyde on the mechanical behavior of bovine pericardium. Biomaterials3:21–26, 1982.

    Google Scholar 

  17. Vesely, I. A mechanism for the decrease in stiffness of heart valve tissues after crosskicking. ASAIO J.42:993–999, 1996.

    Google Scholar 

  18. Vesely, I.The hybrid autograft/xenograft bioprosthetic heart valve. J. Heart Valve Dis.6:292–295, 1997.

    Google Scholar 

  19. Vesely, I.The role of elastin in aortic valve mechanics. J. Biomech.31:115–123, 1998.

    Google Scholar 

  20. Vesely, I., A. Lozon, and E. Talman. Is zero-pressure fixation of bioprosthetic valves truly stress free?J. Thorac. Cardiovasc. Surg.106:288–298, 1993.

    Google Scholar 

  21. Vesely, I., and R. Noseworthy. Micromechanics of the fibrosa and the ventricularis in aortic valve leaflets. J. Biomech.25:101–113, 1992.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Carew, E.O., Patel, J., Garg, A. et al. Effect of Specimen Size and Aspect Ratio on the Tensile Properties of Porcine Aortic Valve Tissues. Annals of Biomedical Engineering 31, 526–535 (2003). https://doi.org/10.1114/1.1568116

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1114/1.1568116

Navigation