Minim Invasive Neurosurg 2007; 50(3): 140-144
DOI: 10.1055/s-2007-985151
Original Article

© Georg Thieme Verlag KG Stuttgart · New York

Neuronavigation-Assisted Surgery for Distal Anterior Cerebral Artery Aneurysm

T. S. Kim 1 , S. P. Joo 1 , J. K. Lee 1 , S. Jung 1 , J. H. Kim 1 , S. H. Kim 1 , S. S. Kang 1 , W. Yoon 2
  • 1Department of Neurosurgery, Chonnam National University Medical School, Gwangju, Korea
  • 2Department of Radiology, Chonnam National University Medical School, Gwangju, Korea
Further Information

Publication History

Publication Date:
19 September 2007 (online)

Abstract

Objective: We present our experience with the neuronavigation system as used for surgery of distal anterior cerebral artery (DACA) aneurysm.

Methods: Between 2001 and 2004, 12 patients with a DACA aneurysm were consecutively treated with direct clipping assisted by the neuronavigation system. We used the BrainLAB Vector Vision2 neuronavigation system (BrainLAB, Heimstetten, Germany). Seven out of 12 patients presented with subarachnoid hemorrhage. Aneurysms were located at distal A2 in 10 patients and distal A3 in two patients. The size of the aneurysms ranged from 3-10 mm.

Results: There were no procedure-related complications or technical problems during application of the neuronavigation system. The registration accuracy ranged from 0.5-1.5 mm (mean: 0.88 mm). The neuronavigation system provided real-time presentation of the DACA and the aneurysm, and allowed for identification of the DACA aneurysm in all patients. No surgical complications developed, and all 12 patients had a good recovery after direct clipping.

Conclusion: Although current neuronavigation systems are not available for all intracranial aneurysms, we believe that the DACA aneurysm is a good candidate for its use. The additional benefits of a small craniotomy and precise intraoperative orientation during surgery result in a minimally invasive aneurysm procedure.

References

  • 1 Schmid-Elsaesser R, Muacevic A, Holtmannspotter M, Uhl E, Steiger HJ. Neuronavigation based on CT angiography for surgery of intracranial aneurysms: primary experience with unruptured aneurysms.  Minim Invas Neurosurg. 2003;  46 269-277
  • 2 Lee JY, Lunsford LD, Subach BR, Jho HD, Bissonette DJ, Kondziolka D. Brain surgery with image guidance: current recommendations based on a 20-year assessment.  Stereotact Funct Neurosurg. 2000;  75 35-48
  • 3 Kleinpeter G, Lothaller C. Frameless neuronavigation using the ISG-system in practice: from craniotomy to delineation of lesion.  Minim Invas Neurosurg. 2003;  46 257-264
  • 4 Cheng WY, Shen CC. Minimally invasive approaches to treat simultaneous occurrence of glioblastoma multiforme and intracranial aneurysm - case report.  Minim Invas Neurosurg. 2004;  47 181-185
  • 5 Yasargil MG. Clinical considerations, surgery of intracranial aneurysms and results. In: Yarsargil MG Microneurosurgery. Vol. II Stuttgart: Georg Thieme Verlag 1984: 224-231
  • 6 Hernesniemi J, Tapaninaho A, Vapalahti M, Niskanen M, Kari A, Luukkonen M. Saccular aneurysms of the distal anterior cerebral artery and its branches.  Neurosurgery. 1992;  31 994-998
  • 7 Proust F, Toussaint P, Hannequin D, Rabenenoina C, Le Gars D, Freger P. Outcome in 43 patients with distal anterior cerebral artery aneurysms.  Stroke. 1997;  28 2405-2409
  • 8 Sousa AA de, Dantas FL, Cardoso GT de, Costa BS. Distal anterior cerebral artery aneurysms.  Surg Neurol. 1999;  52 128-135
  • 9 Miyazawa N, Nukui H, Yagi S, Yamagata Z, Horikoshi T, Yagishita T, Sugita M. Statistical analysis of factors affecting the outcome of patients with ruptured distal anterior cerebral artery aneurysms.  Acta Neurochir (Wien). 2000;  142 1241-1246
  • 10 Rhoton Jr AL. Aneurysms.  Neurosurgery. 2002;  51 ((4 Suppl)) S121-S158
  • 11 Rhoton Jr AL. The supratentorial arteries.  Neurosurgery. 2002;  51 ((4 Suppl)) S53-S120
  • 12 Kawashima M, Matsushima T, Sasaki T. Surgical strategy for distal anterior cerebral artery aneurysms: microsurgical anatomy.  J Neurosurg. 2003;  99 517-525
  • 13 Chhabra R, Gupta SK, Mohindra S, Mukherjee K, Bapuraj R, Khandelwal N, Khosla VK. Distal anterior cerebral artery aneurysms: bifrontal basal anterior interhemispheric approach.  Surg Neurol. 2005;  64 315-319
  • 14 Gumprecht HK, Widenka DC, Lumenta CB. BrainLab VectorVision Neuronavigation System: technology and clinical experiences in 131 cases.  Neurosurgery. 1999;  44 97-104
  • 15 Muacevic A, Steiger HJ. Computer-assisted resection of cerebral arteriovenous malformations.  Neurosurgery. 1999;  45 1164-1170
  • 16 Muacevic A, Uhl E, Steiger HJ, Reulen HJ. Accuracy and clinical applicability of a passive marker based frameless neuronavigation system.  J Clin Neurosci. 2000;  7 414-418
  • 17 Tirakotai W, Sure U, Benes L, Krischek B, Bien S, Bertalanffy H. Image-guided transsylvian, transinsular approach for insular cavernous angiomas.  Neurosurgery. 2003;  53 1299-1304
  • 18 Krishnan R, Raabe A, Hattingen E, Szelenyi A, Yahya H, Hermann E, Zimmermann M, Seifert V. Functional magnetic resonance imaging-integrated neuronavigation: correlation between lesion-to-motor cortex distance and outcome.  Neurosurgery. 2004;  55 904-914
  • 19 Reinhardt HF, Horstmann GA, Gratzl O. Sonic stereometry in microsurgical procedures for deep-seated brain tumors and vascular malformations.  Neurosurgery. 1993;  32 51-57
  • 20 Barnett GH, Kormos DW, Steiner CP, Weisenberger J. Use of a frameless, armless stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging.  Neurosurgery. 1993;  33 674-678
  • 21 Giorgi C. Intraoperative fusion of field images with CT/MRI data by means of a stereotactic mechanical arm.  Minim Invas Neurosurg. 1994;  37 53-55
  • 22 Westermann B, Trippel M, Reinhardt H. Optically-navigable operating microscope for image-guided surgery.  Minim Invasive Neurosurg. 1995;  38 112-116
  • 23 Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF. Clinical use of a frameless stereotactic arm: results of 325 cases.  J Neurosurg. 1995;  83 197-205
  • 24 Reinhardt HF, Trippel M, Westermann B, Horstmann GA, Gratzl O. Computer assisted brain surgery for small lesions in the central sensorimotor region.  Acta Neurochir (Wien). 1996;  138 200-205
  • 25 Ungersbock K, Aichholzer M, Gunthner M, Rossler K, Gorzer H, Koos WT. Cavernous malformations: from frame-based to frameless stereotactic localization.  Minim Invas Neurosurg. 1997;  40 134-138
  • 26 Roessler K, Ungersboeck K, Dietrich W, Aichholzer M, Hittmeir K, Matula C, Czech T, Koos WT. Frameless stereotactic guided neurosurgery: clinical experience with an infrared based pointer device navigation system.  Acta Neurochir (Wien). 1997;  139 551-559
  • 27 Shelden CH, MacCann G, Jacques S, Lutes HR, Frazier RE, Katz R, Kuki R. Development of a computerized microstereotaxic method for localization and removal of minute CNS lesions under direct 3-D vision. Technical report.  J Neurosurg. 1980;  52 21-27
  • 28 Jacques S, Shelden CH, MacCann GD, Freshwater DB, Rand R. Computerized three-dimensional stereotaxic removal of small central nervous system lesions in patients.  J Neurosurg. 1980;  53 816-820
  • 29 Kelly PJ, Alker Jr GJ, Goerss S. Computer-assisted stereotactic microsurgery for the treatment of intracranial neoplasms.  Neurosurgery. 1982;  10 324-331
  • 30 Roberts DW, Strohbehn JW, Hatch JF, Murray W, Kettenberger H. A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope.  J Neurosurg. 1986;  65 545-549
  • 31 Watanabe E, Watanabe T, Manaka S, Mayanagi Y, Takakura K. Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery.  Surg Neurol. 1987;  27 543-547
  • 32 Kato A, Yoshimine T, Hayakawa T, Tomita Y, Ikeda T, Mitomo M, Harada K, Mogami H. A frameless, armless navigational system for computer-assisted neurosurgery. Technical note.  J Neurosurg. 1991;  74 845-849
  • 33 Koivukangas J, Louhisalmi Y, Alakuijala J, Oikarinen J. Ultrasound-controlled neuronavigator-guided brain surgery.  J Neurosurg. 1993;  79 36-42
  • 34 Barnett GH, Kormos DW, Steiner CP, Weisenberger J. Intraoperative localization using an armless, frameless stereotactic wand.  Technical note. J Neurosurg. 1993;  78 510-514
  • 35 Tan KK, Grzeszczuk R, Levin DN, Pelizzari CA, Chen GT, Erickson RK, Johnson D, Dohrmann GJ. A frameless stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note.  J Neurosurg. 1993;  79 296-303

Correspondence

T. S. KimMD 

Department of Neurosurgery

Chonnam National University Medical School

5 Hakdong

Dong-gu

501-757 Gwangu

Republic of Korea

Phone: +82/62/220 66 07

Fax: +82/62/224 98 65