Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

Effect of grid-connected solid oxide fuel cell power generation on power systems small-signal stability

Effect of grid-connected solid oxide fuel cell power generation on power systems small-signal stability

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Renewable Power Generation — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

This study investigates one of the most fundamental issues of integrating fuel cell (FC) generation into power systems – its effect on power system small-signal stability when it operates jointly with conventional power generation. The study first presents a comprehensive mathematical model of the solid oxide fuel cell (SOFC) power plant integrated with the single-machine infinite-bus power system. Based on the model, conventional damping torque analysis is carried out to study the effect of SOFC power generation on power system small-signal stability. The analysis concludes that system small-signal stability can be affected either positively or negatively by the SOFC power plant when system operating conditions change. Two examples of power systems with gird-connected SOFC power plants are presented. Small-signal stability of the first example of single-machine power system was examined when the power system operated at different load conditions and levels of mixtures of conventional and FC power generation. The second example is a four-machine two-area power system where the power supplied by the gird-connected SOFC power plant is variable. Results of simulation using full non-linear model of the power systems and the SOFC power plants are given. All the results from the example power systems confirm and further demonstrate the analysis presented and conclusions obtained.

References

    1. 1)
    2. 2)
    3. 3)
      • Georgakis, D., Papathanassiou, S., Manias, S.: `Modelling and control of a small scale grid-connected PEM fuel cell system', Proc. IEEE 36th Power Electronics Specialists Conf., 2005, p. 1614–1620.
    4. 4)
    5. 5)
      • H.F. Wang . Phillips–Heffron model of power systems installed with STATCOM and applications. IEE Proc. Part C , 5 , 521 - 527
    6. 6)
    7. 7)
    8. 8)
      • CIGRE technical report: ‘Modeling of power electronics equipment (FACTS) in load flow and stability programs’, CIGRE T F 38-01-08, 1998.
    9. 9)
      • Y.N. Yu . (1983) Electric power system dynamics.
    10. 10)
    11. 11)
      • P. Kundur . (1994) Power system stability and control.
    12. 12)
    13. 13)
    14. 14)
      • W.G. Heffron , R.A. Phillips . Effect of a modem amplidyne voltage regulator on under excited operation of large turbine generator. AIEE Trans. , 692 - 697
    15. 15)
    16. 16)
    17. 17)
      • Shen, C., Yang, Z., Crow, M.L., Atcitty, S.: `Control of STATCOM with energy storage device', IEEE Power Engineering Society Winter Meeting, 2000, 23–27 January 2000, 4, p. 2722–2728.
    18. 18)
    19. 19)
    20. 20)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2010.0024
Loading

Related content

content/journals/10.1049/iet-rpg.2010.0024
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address