Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

Probabilistic approach for optimal allocation of wind-based distributed generation in distribution systems

Probabilistic approach for optimal allocation of wind-based distributed generation in distribution systems

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Renewable Power Generation — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Recent development in small renewable/clean generation technologies such as wind turbines, photovoltaic, fuel cells, microturbines and so on has drawn distribution utilities' attention to possible changes in the distribution system infrastructure and policy by deploying distributed generation (DG) in distribution systems. In this study, a methodology has been proposed for optimally allocating wind-based DG units in the distribution system so as to minimise annual energy loss. The methodology is based on generating a probabilistic generation–load model that combines all possible operating conditions of the wind-based DG units and load levels with their probabilities, hence accommodating this model in a deterministic planning problem. The planning problem is formulated as mixed integer non-linear programming (MINLP), with an objective function for the system's annual energy losses minimise. The constraints include voltage limits at different buses (slack and load buses) of the system, feeder capacity, discrete size of the DG units, maximum investment on each bus, and maximum penetration limit of DG units. This proposed technique is applied to a typical rural distribution system and compared to the traditional planning technique (constant output power of DG units and constant peak load profile).

References

    1. 1)
      • D.H. Popovic , J.A. Greatbanks , M. Begovic , A. Pregelj . Placement of distributed generations and reclosers for distribution network security and reliability. Int. J. Electr. Power Energy Syst. , 398 - 408
    2. 2)
      • C. Singh , Y. Kim . An efficient technique for reliability analysis of power systems including time dependent sources. IEEE Trans. Power Syst. , 3 , 1090 - 1096
    3. 3)
      • R.E. Rosenthal . GAMS – a user's guide.
    4. 4)
      • W. El-Khattam , K. Bahtasharia , Y. Hegazy , M.M.A. Salama . Optimal investment planning for distributed generation in a competitive electricity market. IEEE Trans. Power Syst. , 3 , 1674 - 1684
    5. 5)
      • J.O. Kim , S.K. Park , K.W. Park , C. Singh . Dispersed generation planning using improved Hereford Ranch algorithm. Electr. Power Syst. Res. , 1 , 678 - 683
    6. 6)
      • C. Wang , M.H. Nehrir . Analytical approaches for optimal placement of distributed generation sources in power systems. IEEE Trans. Power Syst. , 4 , 2068 - 2076
    7. 7)
      • C. Singh , A. Lago-Gonzales . Improved algorithms for multi-area reliability evaluation using decomposition-simulation approach. IEEE Trans. Power Syst. , 1 , 321 - 328
    8. 8)
      • R. Karki , R. Billinton . Cost-effective wind energy utilization for reliable power supply. IEEE Trans. Energy Convers. , 2 , 435 - 440
    9. 9)
      • J.M.S. Pinheiro , C.R.R. Dornellas , A.C.G. Melo . Probing the new IEEE reliability test system (RTS-96): HL-II assessment. IEEE Trans. Power Syst. , 1 , 171 - 176
    10. 10)
      • IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems.
    11. 11)
      • Rahman, T.K.A., Rahim, S.R.A., Musirin, I.: `Optimum location and sizing of embedded generators', Proc. National Power and Energy Conf., November 2004.
    12. 12)
      • Gandomkar, M., Vakilini, M., Ehsan, M.: `Optimal distributed generation allocation in distribution network using Hereford Ranch algorithm', Proc. Int. Conf. on Electrical Mechanics and Sytems, September 2005, 2.
    13. 13)
      • Griffin, T., Tomsovic, K., Secrest, D., Law, A.: `Placement of dispersed generations system for reduced losses', Proc. 33rd Hawaii, Int. Conf. on Systemic Science, January 2000.
    14. 14)
      • Carpinelli, G., Celli, G., Pilo, F., Russo, A.: `Distributed generation sitting and sizing under uncertainty', IEEE Porto Power Tech Conf., September 2001.
    15. 15)
      • Celli, G., Pilo, F.: `Optimal distributed generation allocation in MV network', Proc. 22nd IEEE PES Int. Conf. on Power Industries and Computer Applications, May 2001.
    16. 16)
      • Greatbanks, J.A., Popovic, D.H., Begovic, M., Pregelj, A., Green, T.C.: `On optimization for security and reliability of power systems with distributed generation', Proc. IEEE Bologna Power Tech Conf., June 2003.
    17. 17)
      • Celli, G., Pilo, F.: `MV network planning under uncertainty on distributed generation penetration', Proc. IEEE PES Summer Meeting, July 2001, 1.
    18. 18)
      • G. Boyle . (2004) Renewable energy.
    19. 19)
      • Nara, K., Hayashi, Y., Ikeda, K., Ashizawa, T.: `Application of Tabu search to optimum placement of distributed generations', Proc. IEEE Winter Meeting, January 2001, 2.