Issue 6, 2015

A HPLC-SRM-MS based method for the detection and quantification of methotrexate in urine at doses used in clinical practice for patients with rheumatological disease: a potential measure of adherence

Abstract

Rheumatoid arthritis (RA) is a common autoimmune disease that causes significant disability and reduced life expectancy. The folate antagonist methotrexate (MTX) is first-line therapy for RA when used weekly at low doses (5–25 mg). However, the true rate of adherence to MTX is uncertain. This is in part due to the different methods of measurement of adherence employed with no biochemical test currently available to determine adherence to low dose MTX. Common methods of MTX measurement include immunoassays in patients with high dose therapy, but these assays cross-react with MTX metabolites and lack the sensitivity required to measure adherence to low dose MTX. HPLC-SRM-MS (selected reaction monitoring-mass spectrometry) has several theoretical advantages over immunoassays with improved specificity, minimal cross-reaction and higher sensitivity. The aim of this study was to develop an assay to measure MTX and its major metabolite 7-OH-MTX in urine as a tool to monitor adherence to low dose MTX in clinic. As a proof of concept, urine samples from 4 participants with RA were measured after directly observed therapy. The assay showed improved sensitivity compared to that reported by immunoassays, with low carryover and high within-run precision. In participant samples, MTX was measurable in the urine for up to 105 hours after administration and 7-OH-MTX was detectable up to 98 hours after administration, suggesting that this assay is suitable for the measurement of adherence to therapy. The assay requires minimal sample preparation and can be adopted by other laboratories with minimal study set up.

Graphical abstract: A HPLC-SRM-MS based method for the detection and quantification of methotrexate in urine at doses used in clinical practice for patients with rheumatological disease: a potential measure of adherence

Article information

Article type
Paper
Submitted
16 Dec 2014
Accepted
02 Feb 2015
First published
02 Feb 2015

Analyst, 2015,140, 1981-1987

Author version available

A HPLC-SRM-MS based method for the detection and quantification of methotrexate in urine at doses used in clinical practice for patients with rheumatological disease: a potential measure of adherence

J. Bluett, I. Riba-Garcia, K. Hollywood, S. M. M. Verstappen, A. Barton and R. D. Unwin, Analyst, 2015, 140, 1981 DOI: 10.1039/C4AN02321H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements