Radiation Peak Skin Dose to Risk Stratify Electrophysiological Procedures for Deterministic Skin Damage

  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Ionising radiation is has the potential to cause harm both by increasing the probability future malignancy (stochastic mechanisms) and by direct physical injury (deterministic mechanisms). Several measures have been developed to quantify radiation exposure during a procedure and cardiologists usually refer to fluoroscopic screening time (FST). FST, however, has limitations for predicting deterministic injury which is directly dependant on peak skin dose (PSD). We compared FST to PSD for a range of interventional cardiac electrophysiology procedures. Methods: All patients undergoing electrophysiology procedures during a 2-month period in our institution were studied. Demographic details, nature of procedure, FST and PSD were measured. The FST to PSD ratio was calculated and compared between patient and procedural factors. Results: 67 procedures on patients (23 female) with body mass index (BMI) of 28 (SD 5)Kg/m2 were studied. Screening times ranged from 0.2 to 96.6 min (median 11.2). PSD ranged from <0.1 to 1108 mGy (median 141). There was a positive correlation between PSD to FST ratio and BMI (r= 0.59, p < 0.001). The PSD to FST ratio was higher in cardiac resynchronization therapy (CRT) devices than single or dual chamber ICDs (p= 0.002). Conclusion: FST is not a reliable predictor of deterministic skin injury and in high-risk procedures such as CRT devices and those on individuals of high BMI PSD should be measured.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wagner LK, Eifel PJ, Geise RA.Potential biological effects following high X-ray dose interventional procedures. J Vasc Interv Radiol 1994;5:71–84.

    Google Scholar 

  2. Bond VP.Dose,effect severity,and imparted energy in assessing biological effects.Stem Cells 1995;13 Suppl 1:21–29.

    Google Scholar 

  3. Faulkner K, Broadhead DA, Harrison RM.Patient dosimetry measurement methods.Appl Radiat Isot 1999; 50:113–123.

    Google Scholar 

  4. Macle L, Jais P, Scavee C, Weerasooriya R, Hocini M, Shah DC,et al.Pulmonary vein disconnection using the LocaLisa three-dimensional non fiuoroscopic catheter imaging system. J Cardiovasc Electrophysiol 2003;14:693–697.

    Google Scholar 

  5. Sayad DE, Sawar A, Curkovic V, Gallardo I, Barold SS. Simple access to the coronary venous system for left ven-tricular pacing.Pacing Clin Electrophysiol 2003;26:1856–1858.

    Google Scholar 

  6. Koenig TR, Wolff D, Mettler FA, Wagner LK.Skin injuries from fiuoroscopically guided procedures:part 1,character-istics of radiation injury.AJR Am J Roentgenol 2001;177: 3–11.

    Google Scholar 

  7. Hopewell JW.The skin:its structure and response to ion-izing radiation.Int J Radiat Biol 1990;57:751–773.

    Google Scholar 

  8. Vano E, Gonzalez L, Ten JI, Fernandez JM, Guibelalde E, Macaya C.Skin dose and dose-area product values for in-terventional cardiology procedures.Br J Radiol 2001;74: 48–55.

    Google Scholar 

  9. Miller DL, Balter S, Cole PE, Lu HT, Berenstein A, Albert R,et al.Radiation doses in interventional radiology pro-cedures:the RAD-IR study:part II:skin dose.J Vasc Interv Radiol 2003;14:977–990.

    Google Scholar 

  10. Blanc JJ, Benditt DG, Gilard M, Etienne Y, Mansourati J, Lurie KG.A method for permanent transvenous left ven-tricular pacing.Pacing Clin Electrophysiol 1998;21:2021–2024.

    Google Scholar 

  11. McParland BJ.Entrance skin dose estimates derived from dose-area product measurements in interventional radio-logical procedures.Br J Radiol 1998;71:1288–1295.

    Google Scholar 

  12. van de PS, Verhaegen F, Taeymans Y, Thierens H.Corre-lation of patient skin doses in cardiac interventional radiology with dose-area product.Br J Radiol 2000;73: 504–513.

    Google Scholar 

  13. Vehmas T.Radiation exposure during standard and com-plex interventional procedures.Br J Radiol 1997;70:296–298.

    Google Scholar 

  14. Kovoor P, Ricciardello M, Collins L, Uther JB, Ross DL. Risk to patients from radiation associated with radiofre-quency ablation for supraventricular tachycardia.Circula-tion 1998;98:1534–1540.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Paisey, J., Yue, A., White, A. et al. Radiation Peak Skin Dose to Risk Stratify Electrophysiological Procedures for Deterministic Skin Damage. Int J Cardiovasc Imaging 20, 285–288 (2004). https://doi.org/10.1023/B:CAIM.0000041943.73199.d3

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/B:CAIM.0000041943.73199.d3

Navigation