Skip to main content
Log in

Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images

  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

The present study was designed to evaluate the feasibility and clinical usefulness of three-dimensional (3D) reconstruction of intra-cardiac anatomy from a series of two-dimensional (2D) MR images using commercially available software. Sixteen patients (eight with structurally normal hearts but due to have catheter radio-frequency ablation of atrial tachyarrhythmias and eight with atrial septal defects (ASD) due for trans-catheter closure) and two volunteers were imaged at 1T. For each patient, a series of ECG-triggered images (5 mm thick slices, 2–3 mm apart) were acquired during breath holding. Depending on image quality, T 1- or T 2-weighted spin-echo images or gradient-echo cine images were used. The 3D reconstruction was performed off-line: the blood pools within cardiac chambers and great vessels were semi-automatically segmented, their outer surface was extracted using a marching cube algorithm and rendered. Intra- and inter-observer variability, effect of breath-hold position and differences between pulse sequences were assessed by imaging a volunteer. The 3D reconstructions were assessed by three cardiologists and compared with the 2D MR images and with 2D and 3D trans-esophagal and intra-cardiac echocardiography obtained during interventions. In every case, an anatomically detailed 3D volume was obtained. In the two patients where a 3 mm interval between slices was used, the resolution was not as good but it was still possible to visualize all the major anatomical structures. Spin-echo images lead to reconstructions more detailed than those obtained from gradient-echo images. However, gradient-echo images are easier to segment due to their greater contrast. Furthermore, because images were acquired at least at ten points in the cardiac cycles for every slice it was possible to reconstruct a cine loop and, for example, to visualize the evolution of the size and margins of the ASD during the cardiac cycle. 3D reconstruction proved to be an effective way to assess the relationship between the different parts of the cardiac anatomy. The technique was useful in planning interventions in these patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Robb RA. Three-dimensional visualization in medicine and biology. In: Bankman IN, editor. Handbook of Medical Imaging: Processing and Analysis, 2000; 685–730.

  2. Roelandt JRTC, Yao J, Kasprzak JD. Three-dimensional echocardiography. Curr Opin Cardiol 1998; 13: 386–396.

    Google Scholar 

  3. De Castro S, Yao J, Pandian NG. Three-dimensional echocardiography: clinical relevance and application. Am J Cardiol 1998; 81(12A): 96G–102G.

    Google Scholar 

  4. Li J, Sanders SP. Three-dimensional echocardiography in congenital heart disease. Curr Opin Cardiol 1999; 14: 53–59.

    Google Scholar 

  5. Tantengco MTV, Bates JR, Ryan T, Caldwell R, Darragh R, Ensing GJ. Dynamic three-dimensional echocardiographic reconstrucion of cardiac septation defects. Pediatr Cardiol 1997; 18: 184–190.

    Google Scholar 

  6. Neimatallah MA, Ho VB, Dong Q, et al. Gadolinium-enhanced 3D magnetic resonance angiography of the thoracic vessels. J Magn Reson Imaging 1999; 10(5): 758–770.

    Google Scholar 

  7. Toombs BD, Jing JM. Current concepts in the evaluation of vascular disease - magnetic resonance and computed tomographic angiography, Tex Heart I J 2000; 27(2): 170–192.

    Google Scholar 

  8. Ho VB, Prince MR, Dong Q. Magnetic resonance imaging of the aorta and branch vessels. Coronary Artery Dis 1999; 10(3): 141–149.

    Google Scholar 

  9. Westra SJ, Hurteau J, Galindo A, McNitt-Gray MF, Boechat MI, Laks H. Cardiac electron-beam CT in children undergoing surgical repair for pulmonary atresia. Radiology 1999; 213(2): 502–512.

    Google Scholar 

  10. Kachelriess M, Ulzheimer S, Kalender WA. ECG-correlated imaging of the heart with subsecond multislice spiral CT. IEEE T Med Imaging 2000; 19(9): 888–901.

    Google Scholar 

  11. Vick GW. Three-and four-dimensional visualization of magnetic resonance imaging data sets in pediatric cardiology. Pediatr Cardiol 2000; 21: 27–36.

    Google Scholar 

  12. Chen S-J, Li Y-W, Chiu I-S, Su C-T, Hsu JC-Y, Lue H-C. Three-dimensional reconstruction of abnormal ventriculoatrerial relationship by electron beam CT. J Comput Assist Tomography 1998; 22(4): 560–568.

    Google Scholar 

  13. Kawano T, Ishii M, Takagi J, et al. Three-dimensional helical computed tomographic angiography in neonates and infants with complex congenital heart disease. Am Heart J 2000; 139(4): 654–660.

    Google Scholar 

  14. Cline HE, Lorensen WE, Hardy CJ, Dumoulin CL, Ludke S. 3D cardiac image processing. Proceedings of the 5th Annual Meeting, ISMRM, 1997; 2029.

  15. Sørensen TS, Therkidsen SV, Makowski P, Knudsen JL, Pedersen EM. Real-time interactive visualization of the cardiovascular system based on cardiac MRI. Proceedings of the 8th Annual Meeting, ISMRM, 2000; 1552.

  16. Razavi RS, Miquel ME, Goodey J, Baker EJ. Gadolinium enhanced magnetic resonance angiography of pulmonary venous abnormalities. Magn Reson Mater Phys 2000; 11 (Suppl 1): 68.

    Google Scholar 

  17. Okuda S, Kikinis R, Geva T, Chung T, Dumanli H, Powell AJ. 3D-shaded surface rendering of gadolinium-enhanced MR angiography in congenital heart disease. Pediatr Radiol 2000; 30(8): 540–545.

    Google Scholar 

  18. Wigström L, Ebbers T, Fyrenius A, Karlsson M, Engvall J, Bolger AF. Particle trace visualization on intracardiac flow using time-resolved 3D phase contrast MRI. Magn Reson Med 1999; 41: 793–799.

    Google Scholar 

  19. Kilner PJ, Yang G-Z, Wilkes AJ, Mohiaddin RH, Firmin DN, Yacoub MH. Asymmetric redirection of flow through the heart. Nature 2000; 404: 759–761.

    Google Scholar 

  20. Young AA. Model tags: direct 3D tracking of heart wall motion from tagged MR images. Lect Notes Comput Sci 1998; 1496: 92–101.

    Google Scholar 

  21. Moore CC, Lugo-Olivieri CH, McVeigh ER, Zerhouni EA. Three-dimensional systolic strain patterns in the normal human left ventricle: characterization with taggedMRimaging. Radiology 2000; 214(2): 453–466.

    Google Scholar 

  22. Marchlinski FE, Callans DJ, Gottlieb CD, Zado E. Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation 2000; 101(11): 1288–1296.

    Google Scholar 

  23. Dall'Agata A, McGhie J, Cromme-Dijkuis AH, et al. Secundum atrial septal defect is a dynamic three-dimensional entity. Am Heart J 1999; 137: 1075–1081.

    Google Scholar 

  24. Maeno YV, Benson LN, Boutin C. Impact of dynamic 3D transoesophageal echocardiography in the assessment of atrial septal defects and occlusion by the double-umbrella device (CardioSEAL). Cardiol Young 1998; 8: 368–378.

    Google Scholar 

  25. Simon RD, Razavi R, Miquel ME, et al. Four-dimensional reconstruction of the right atrium - a comparison of intracardiac echocardiography with magnetic resonance imaging. American College of Cardiology Annual Scientific Session, March 18–21, Orlando, abstract 221655, 2001.

  26. Miquel ME, Razavi RS, Clarkson MJ, Baker EJ, Hill DLG, Keevil SF. Three-dimensional MRI reconstruction of intracardiac anatomy. Magn Reson Mater Phys 2000; 11 (Suppl 1): 256.

    Google Scholar 

  27. Miquel ME, Razavi RS, Baker EJ, Hill DLG, Keevil SF. 3D reconstruction of intra-cardiac anatomy: a comparison of magnetic resonance imaging (MRI), intra-cardiac echocardiography (ICE) and trans-esophagal echocardiography (TEE). Proc Intl Soc Magn Reson Med 2001; 9: 1824.

    Google Scholar 

  28. Lorensen W, Cline H. Marching cubes: a high resolution 3D surface construction algorithm. Comput Graph 1987; 21: 163–169.

    Google Scholar 

  29. Schroeder W, Martin K, Lorensen B. The Visualization Toolkit: An Object-Oriented Approach to 3D Graphics. Upper Saddle River: Prentice Hall PTR, 1998. 253

  30. Battle XL, Cunningham GS, Hanson KM. Tomographic reconstruction using 3D deformable models. Phys Med Biol 1998; 43: 983–990.

    Google Scholar 

  31. Reinhardt JM, Wang AJ, Weldon TP, Higgins WE. Cuebased segmentation of 4D cardiac image sequences. Comput Vision Image Underst 2000; 77: 251–262.

    Google Scholar 

  32. Barkhausen J, Ruehm SG, Goyen M, Laub GA, Debatin JF. Assessment of ventricular function in a single breath hold using real-time true FISP Cine imaging. Radiology 2000; 217: 1086.

    Google Scholar 

  33. Thiele H, Paetsch I, Schnackenburg B, et al. Inflow independent functional MR imaging with true FISP significantly improves endocardial border delineation without contrast agents. Eur Heart J 2000; 21: 572–572.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Miquel, M., Hill, D., Baker, E. et al. Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images. Int J Cardiovasc Imaging 19, 239–254 (2003). https://doi.org/10.1023/A:1023671031207

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1023671031207

Navigation