Skip to main content
Log in

A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring

  • Published:
Journal of Fluorescence Aims and scope Submit manuscript

Abstract

We have developed a range of glucose sensing contact lenses, using a daily, disposable contact lens embedded with newly developed boronic acid containing fluorophores. Our findings show that our approach may be suitable for the continuous monitoring of tear glucose levels in the range 50–1000 μM, which typically track blood glucose levels, which are ≈5–10 fold higher. Our non-invasive approach may well offer an alternative solution to current invasive glucose monitoring techniques for diabetes, such as “finger pricking.”

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

REFERENCES

  1. M. R. Robinson, R. P. Eaton, D. M. Haaland, G. W. Koepp, E. V. Thomas, B. R. Stallard, and P. L. Robinson (1992). Non-invasive glucose monitoring in diabetic patients: A preliminary evaluation. Clin. Chem. 38, 1618-1622.

    Google Scholar 

  2. H. M. Heise, R. Marbach, T. H. Koschinsky, and F. A. Gries (1994). Non-invasive blood glucose sensors based on near-infrared spectroscopy. Ann. Occup. Hyg. 18, 439-447.

    Google Scholar 

  3. W. F. March, B. Rabinovitch, R. Adams, J. R. Wise, and M. Melton (1982). Ocular glucose sensor. Trans. Am. Soc. Artif. Intern. Organs 28, 232-235.

    Google Scholar 

  4. B. Rabinovitch, W. F. March, and R. L. Adams (1982). Non-invasive glucose monitoring of the aqueous humor of the eye, Part 1, Measurement of very small optical rotations. Diabetes Care 5, 254-258.

    Google Scholar 

  5. G. M. Schier, R. G. Moses, I. E. T. Gan, and S. C. Blair (1988). An evaluation and comparison of reflolux Iiand Glucometer II, two new portable reflectance meters for capillary blood glucose determination. Diabetes Res. Clin. Pract. 4, 177-181.

    Google Scholar 

  6. W. Clarke, D. J. Becker, D. Cox, J. V. Santiago, N. H. White, J. Betschart, K. Eckenrode, L. A. Levandoski, E. A. Prusinki, L. M. Simineiro, A. L. Snyder, A. M. Tideman, and T. Yaegar (1988). Evaluation of a new system for self blood glucose monitoring. Diabetes Res. Clin. Pract. 4, 209-214.

    Google Scholar 

  7. W. Trettnak and O. S. Wolfbeis (1989). Fully reversible fiber-optic glucose biosensor based on the intrinsic fluorescence of glucose-oxidase. Anal. Chim. Acta 221, 195-203.

    Google Scholar 

  8. D. Meadows and J. S. Schultz (1988). Fibre optic biosensor based on fluorescence energy transfer. Talanta 35, 145-150.

    Google Scholar 

  9. L. Tolosa, H. Malak, G. Rao, and J. R. Lakowicz (1997). Optical assay for glucose based on the luminescence decay time of the long wavelength dye Cy5. Sens. Actuators B. 45, 93-99.

    Google Scholar 

  10. L. Tolosa, I. Gryczynski, L. R. Eichorn, J. D. Dattelbaum, F. N. Castellano, G. Rao, and J. R. Lakowicz (1999). Glucose sensors for low cost lifetime-based sensing using a genetically engineered protein. Anal. Biochem. 267, 114-120.

    Google Scholar 

  11. S. D'Auria, N. Dicesare, Z. Gryczynski, I. Gryczynski, M. Rossi, and J. R. Lakowicz (2000). Athermophilic apoglucose dehydrogenase as a nonconsuming glucose sensor. Biochem. Biophys. Res. Commun. 274, 727-731.

    Google Scholar 

  12. D. Michail, N. Zolog (1937). Sur l'elimination lacrymale du glucose au cours dr l'hyperglycemie alimentaire. C. R. Soc. Biol. Paris 126, 1042.

    Google Scholar 

  13. D. Michail, P. Vancea, and N. Zolog (1937). Sur l'elimination lacry-male du glucose chez les diabetiques. C. R. Soc. Biol., Paris 125, 1095.

    Google Scholar 

  14. N. J. Van Haeringen (1981). Clinical biochemistry of tears. Surv. Ophthalmol. 29(2), 84-96.

    Google Scholar 

  15. K. M. Daum and R. M. Hill (1982). Human tear glucose. Invest. Ophthalmol. Vis. Sci. 22(4), 509-514.

    Google Scholar 

  16. A. R. Gasser, L. E. Braverman, M. C. Fleming, R. A. Arky, and B. R. Alter (1968). Tear glucose detection in hyperglycemia. Am. J. Ophthalmol. 65(3), 414-420.

    Google Scholar 

  17. B. N. Das, S. Sengupta, B. K. Das and N. R. Goswami (1995). Tear Glucose estimation-An alternative to blood glucose estimation. J. Indian Med. Assoc. 93(4), 127-128.

    Google Scholar 

  18. A. Giardiai and J. R. E. Roberts (1950). Concentration of glucose and total chloride in tears. Br. J. Ophthalmol. 34, 737-743.

    Google Scholar 

  19. F. Ridley (1930). The intra-ocular pressure and drainage of aqueous humour. Br. J. Exp. Pathol. 11, 217-222.

    Google Scholar 

  20. T. D. James, K. R. A. S. Sandanayake, and S. Shinkai (1994). Angew. Chem. Int. Ed. Engl. 33, 2207.

    Google Scholar 

  21. T. D. James, K. R. A. S. Sandanayake, R. Iguchi, and S. Shinkai (1995). J. Am. Chem. Soc. 117, 8982.

    Google Scholar 

  22. M. Bielecki, H. Eggert, and J. C. Norrild (1999). J. Chem. Soc. Perkin Trans. 2, 449.

    Google Scholar 

  23. N. Dicesare and J. R. Lakowicz (2001). Evaluation of two synthetic glucose probes for fluorescence-lifetime based sensing. Anal. Biochem. 294, 154-160.

    Google Scholar 

  24. N. Dicesare and J. R. Lakowicz (2001). Wavelength-ratiometric probes for saccharides based on donor-acceptor diphenylpolyenes. J. Photochem. Photobiol. A: Chem. 143, 39-47.

    Google Scholar 

  25. N. Dicesare and J. R. Lakowicz (2001). New color chemosensors for monosaccharides based on Azo dyes. Org. Lett. 3(24), 3891-3893.

    Google Scholar 

  26. N. Dicesare and J. R. Lakowicz (2002). Chalcone-analogue fluorescent probes for saccharides signaling using the boronic acid group. Tetrahedron Lett. 43, 2615-2618.

    Google Scholar 

  27. R. Badugu, J. R. Lakowicz, and C. D. Geddes (in press). Towards the non-invasive continuous monitoring of physiological glucose using a novel monosaccharide-sensing contact lens. J. Phys. Chem. B. Submitted.

  28. Z. Gryczynski, I. Gryczynski, and J. R. Lakowicz (2002). Fluorescence sensing methods. Methods Enzymol. 360, 44-74.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Badugu, R., Lakowicz, J.R. & Geddes, C.D. A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring. Journal of Fluorescence 13, 371–374 (2003). https://doi.org/10.1023/A:1026103804104

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1026103804104

Navigation