Long-term performance of high-albedo roof coatings

https://doi.org/10.1016/S0378-7788(96)01005-5Get rights and content

Abstract

ooling energy savings of 10 to 70% have been achieved by applying high-albedo coatings to residential buildings in California and Florida. Since dirt accumulation can alter the performance of high-albedo roofs as an energy efficiency measure, we examined some high-albedo coatings at various stages of exposure to determine the magnitude of this effect. We conclude that most of the albedo degradation of coatings occurred within the first year of application, and even within the first two months of exposure. On one roof, 70% of the drop in albedo for the entire first year occurred within the first two months. After the first year, the degradation slowed, with data indicating small losses in albedo after the second year. We use measured data to estimate the effects of weathering of white roofs on seasonal cooling energy savings and estimate a 20% reduction from first year energy savings for all subsequent years (2–10). Although washing the roofs with soap is effective at restoring original albedo, calculations show that it is not cost-effective to hire someone to clean a high-albedo roof only to achieve energy savings. Instead, it would be useful to develop and identify dirt-resistant high-albedo coatings.

References (19)

  • H. Akbari et al.

    The impact of summer heat islands on cooling energy consumption and CO2 emissions

  • Aaron E. Byerley et al.

    The long term thermal performance of radiation control coatings

  • H. Akbari et al.

    Monitoring peak power and cooling energy savings of shade trees and white surfaces in the Sacramento municipal utility district (SMUD) service area: data analysis, simulations, and results

  • T.E. Anderson

    Exposure testing and evaluation of performance degradation

  • William Kirn

    The use of elastomeric acrylic roof coatings to reduce the air conditioning load of low slope buildings: a field study and laboratory performance criteria

  • R.W. Anderson

    Preliminary evaluation of radiation control coatings for energy conservation in buildings

  • D.E. Backenstow

    Comparison of white versus black surfaces for energy conservation

  • E.I. Griggs et al.

    The impact of surface reflectance on the thermal performance of roofs: an experimental study

    ASHRAE Trans.

    (1988)
  • Aaron Byerley, Personal communication. Mechanical Engineering Department, Mercer University, Macon, GA,...
There are more references available in the full text version of this article.

Cited by (234)

View all citing articles on Scopus
View full text