Chapter 24 Difficulties and pitfalls in analysis of apoptosis

https://doi.org/10.1016/S0091-679X(01)63028-0Get rights and content

Publisher Summary

Flow cytometry has become the preferred methodology for analysis of apoptosis both in the research environment as well as in clinical settings. This chapter discusses the most common errors in measurement of apoptosis as well as the frequent mistakes in the analysis and interpretation of the data. There are certain issues associated with the inappropriate use of flow cytometry in the analysis of apoptosis. The common pitfalls and inappropriate uses of the methodology are apparent. Some of these problems are generic to most of the methods: they generally pertain to data interpretation, in particular how the frequency of apoptotic cells (apoptotic index) relates to the incidence of cell death in cultures or in tissue. Other problems are specific to particular methods or cell systems.

References (54)

  • P. Meier et al.

    Dying like flies

    Cell

    (1998)
  • M.G. Ormerod et al.

    Cisplatin induced apoptosis in a human ovarian carcinoma cell line without a concomitant internucleosomal degradation of DNA

    Exp. Cell Res.

    (1994)
  • D.L. Vaux et al.

    Cell death in development

    Cell

    (1999)
  • M.J. Arends et al.

    Apoptosis: The role of endonuclease

    Am. J. Pathol.

    (1990)
  • E. Bedner et al.

    Laser scanning cytometry distinguishes lymphocytes, monocytes and granulocytes by differences in their chromatin structure

    Cytometry

    (1997)
  • A. Bedner et al.

    Cell cycle effects and induction of apoptosis caused by infection with human granulocytic Ehrlichiosis pathogen measured by laser scanning cytometry

    Cytometry

    (1998)
  • E. Bedner et al.

    High affinity of binding of fluorescein isothiocynate to eosinophils detected by laser scanning cytometry: A potential source of error in analysis of blood samples utilizing fluorescein-conjugated reagents in flow cytometry

    Cytometry

    (1999)
  • E. Bedner et al.

    Analysis of apoptosis by laser scanning cytometry

    Cytometry

    (1999)
  • G.M. Cohen et al.

    Key morphological features of apoptosis may occur in the absence of internucleosomal DNA fragmentation

    Biochem. J.

    (1992)
  • R.J. Collins et al.

    Internucleosomal DNA cleavage should not be the sole criterion for identifying apoptosis

    Int. J. Radiat. Biol.

    (1992)
  • Z. Darzynkiewicz et al.

    Measurements of cell death by flow cytometry

  • Z. Darzynkiewicz et al.

    Assay of cell cycle kinetics by multivariate flow cytometry

  • Z. Darzynkiewicz et al.

    Features of apoptotic cells measured by flow cytometry

    Cytometry

    (1992)
  • Z. Darzynkiewicz et al.

    Assays of cell viability Discrimination of cells dying by apoptosis

  • Z. Darzynkiewicz et al.

    Cytometry in cell necrobiology: Analysis of apoptosis and accidental cell death (necrosis)

    Cytometry

    (1997)
  • Z. Darzynkiewicz et al.

    Critical aspects in the analysis of apoptosis

    Hum. Cell

    (1998)
  • Z. Darzynkiewicz et al.

    Methods for analysis of apoptosis by flow cytometry

  • Cited by (84)

    • Apoptotic and antiproliferative effects of Stigmast-5-en-3-ol from Dendronephthya gigantea on human leukemia HL-60 and human breast cancer MCF-7 cells

      2018, Toxicology in Vitro
      Citation Excerpt :

      DNA fragmentation is a major hallmark of apoptosis and initiates with the activation of nucleases (Samejima and Earnshaw, 2005). Only a limited amount of DNA is degraded during the early steps of apoptosis, whereas nearly all DNA is fragmented during the latter stages (Darzynkiewicz et al., 2001). Comet assay and DNA laddering analysis are frequently used to identify the extent of DNA damage.

    • Development of dual-fluorescence cell-based biosensors for detecting the influence of environmental factors on nanoparticle toxicity

      2017, Chemosphere
      Citation Excerpt :

      Additionally, NPs may interact with marker molecules or chemical agents, resulting in problems when conducting common toxicity tests (Kroll et al., 2012; Karlsson et al., 2013; Guadagnini et al., 2015). Investigation of apoptosis via AnnexinV/propidium-iodide staining has returned false-positive results in situations where NPs were able to bind propidium iodide and be taken up by intact cells (Darzynkiewicz et al., 2001; Shukla et al., 2005). NPs also interfere with enzyme-linked immunosorbent assays owing to the ability of NPs to adsorb cytokines (Monteiro-Riviere and Inman, 2006; Veranth et al., 2007).

    View all citing articles on Scopus
    View full text