Abstract
The stability of the rehabilitation robot system is an important prerequisite for the safety of patients’ rehabilitation training, and there are few studies on the evaluation method of the stability of the cable-driven rehabilitation robot. Hence, this paper aims to study the evaluation method of the dynamical stability of a cable-driven lower limb rehabilitation robot (CDLR) through comprehensive consideration of the position, cable tension, system stiffness, and velocity of the traction point. The structure and working principle of the CDLR is introduced. The position performance factor, the cable tension performance factor, and the system stiffness performance factor are defined based on the kinematics, dynamics, and system stiffness model of the CDLR. The evaluation index of the static stability of the CDLR is presented by comprehensively considering three performance factors. Considering the safety and comfort of the patients’ training, a velocity influence function is given. Combined with the evaluation index of the static stability and the velocity influence function, the evaluation index of the dynamical stability of the CDLR is proposed. Finally, the stability distribution laws of the CDLR are presented by simulation and experimental study. The rationality and correctness of the stability evaluation index are verified by experiments. The experiment results provide an important reference for structural design, rehabilitation training task planning, and control strategy of the CDLR.
Similar content being viewed by others
References
Bacci ML (2017) A concise history of world population. Wiley, Hoboken
Wang YL, Wang KY, Zhang ZX et al (2020) Analysis of dynamical stability of rigid-flexible hybrid-driven lower limb rehabilitation robot. J Mech Sci Tech 34(4):1735–1748. https://doi.org/10.1007/s12206-020-0335-9
Wang YL, Wang KY, Zhao WY et al (2019) Effects of single crouch walking gaits on fatigue damages of lower extremity main muscles. J Mech. Med. Biol. 19(7):1940046. https://doi.org/10.1142/S0219519419400463
Basteris A, Nijenhuis SM, Stienen AHA (2014) Training modalities in robot-mediated upper limb rehabilitation in stroke: a framework for classication based on a systematic review. J Neuroeng Rehabil. 11:111–126. https://doi.org/10.1186/1743-0003-11-111
Chen SH, Lien WM (2016) Assistive control system for upper limb rehabilitation robot. IEEE Trans Neural Syst Rehabil Eng 24(11):1199–1209. https://doi.org/10.1109/TNSRE.2016.2532478
Ugurlu B, Nishimura M, Hyodo K et al (2014) Proof of concept for robot-aided upper limb rehabilitation using disturbance observers. IEEE Trans Hum-Mach Syst 45(1):110–118. https://doi.org/10.1109/thms.2014.2362816
Rathore A, Wilcox M, Ramirez DZM, et al (2016) Quantifying the human-robot interaction forces between a lower limb exoskeleton and healthy users. In: Proceedings of the in Proceedings of the IEEE 38th Annual International Conference on Engineering in Medicine and Biology Society (EMBC), pp 586–589. https://doi.org/10.1109/EMBC.2016.7590770
Jin X, Prado A, Agrawal SK (2018) Retraining of human gait-are lightweight cable-driven leg exoskeleton designs effective? IEEE Trans Neural Syst Rehabil Eng 26(4):847–855. https://doi.org/10.1109/TNSRE.2018.2815656
Kino H, Yoshitake T, Wada R et al (2018) 3-DOF planar parallel-wire driven robot with an active balancer and its model-based adaptive control. Adv Robot 32(14):766–777. https://doi.org/10.1080/01691864.2018.1493397
Zou YP, Wang N, Wang XQ et al (2018) Design and experimental research of movable cable-driven lower limb rehabilitation robot. IEEE Access 7:2315–2326. https://doi.org/10.1109/access.2018.2887233
Zou YP, Liu K, Wang N, et al (2018) Design and optimization of movable cable-driven lower-limb rehabilitation robot. In: 3rd IEEE international conference on advanced robotics and mechatronics (IEEE ICARM), pp 714–719. https://doi.org/10.1109/icarm.2018.8610872
Zhang LX, Li LL, Zou YP et al (2017) Force control strategy and bench press experimental research of a cable driven astronaut rehabilitative training robot. IEEE Access. 5:9981–9989. https://doi.org/10.1109/access.2017.2702188
Xiao F, Gao Y, Wang Y et al (2018) Design and evaluation of a 7-DOF cable-driven upper limb exoskeleton. J Mech Sci Technol 32(2):855–864. https://doi.org/10.1007/s12206-018-0136-y
Ni WC, Li H, Jiang ZH, Zhang BN, Huang Q et al (2018) Motion and force control method of 7-DOF cable-driven rehabilitation exoskeleton robot. Assem Autom 38(5):595–605. https://doi.org/10.1108/aa-03-2018-041
Tsai YL, Huang JJ, Pu SW et al (2019) Usability assessment of a cable-driven exoskeletal robot for rehabilitation. Front Neurorobot 13(3):1–11. https://doi.org/10.3389/fnbot.2019.00003
Cheng L, Chen M, Zheng WL (2018) Design and control of a wearable hand rehabilitation robot. IEEE Access. 6:74039–74050. https://doi.org/10.1109/ACCESS.2018.2884451
Wang KY, Yin PC, Yang HP et al (2018) The man-machine motion planning of rigid-flexible hybrid lower limb rehabilitation robot. Adv Mech Eng 10(6):1–11. https://doi.org/10.1177/1687814018775865
Wang KY, Di CB, Tang XQ et al (2014) Modeling and simulation to muscle strength training of lower limbs rehabilitation robots. Adv Mech Eng 7(1):1–8. https://doi.org/10.1155/2014/298434
Wang H, Kinugawa J, Kosuge K (2018) Exact kinematic modeling and identification of reconfigurable cable-driven robots with dual-pulley cable guiding mechanisms. IEEE-ASME Trans Mechatron 24(2):774–784. https://doi.org/10.1109/TMECH.2019.2899016
Wang W, Yu L, Yang J (2019) Linear parameter variant modeling and parameter identification of a cable-driven micromanipulator for surgical robot. Proc Inst Mech Eng Part C-J Eng Mech Eng Sci 233(5):1828–1840. https://doi.org/10.1177/0954406218773780
Chen Q, Zi B, Sun Z et al (2019) Design and development of a new cable-driven parallel robot for waist rehabilitation. IEEE/ASME Trans. Mech. 24(4):1497–1507. https://doi.org/10.1109/TMECH.2019.2917294
Asl Hamed Jabbari, Yoon Jungwon (2017) Stable assist-as-needed controller design for a planar cable-driven robotic system. Int J Control Autom Syst 15(6):2871–2882. https://doi.org/10.1007/s12555-016-0492-x
Wang Deri, Ahn Jeongdo, Jung Jinwoo (2017) Winch-integrated mobile end-effector for a cable-driven parallel robot with auto-installation. Int J Control Autom Syst 15(5):2355–2363. https://doi.org/10.1007/s12555-016-0398-7
Meziane R, Cardou P, Otis MJ-D (2019) Cable interference control in physical interaction for cable-driven parallel mechanisms. Mech Mach Theory 132:30–47. https://doi.org/10.1016/j.mechmachtheory.2018.10.002
Tang X (2014) An overview of the development for cable-driven parallel manipulator. Adv Mech Eng 6:823–828. https://doi.org/10.1155/2014/823028
Barbosa AM, Carvalho JCM, Goncalves RS (2018) Cable-driven lower limb rehabilitation robot. J Braz Soc Mech Sci Eng 40(5):244–254. https://doi.org/10.1007/s40430-018-1172-y
Hong HJ, Ali Jabran, Ren L (2018) A review on topological architecture and design methods of cable-driven mechanism. Adv Mech Eng 10(5):1–14. https://doi.org/10.1177/1687814018774186
Behzadipour S, Khajepour A (2006) Stiffness of cable-based parallel manipulators with application to stability analysis. J Mech Des 128(1):303–310. https://doi.org/10.1115/1.2114890
Michael N, Fink J, Kumar V (2011) Cooperative manipulation and transportation with aerial robots. Auton Robot 30(1):73–86. https://doi.org/10.1007/s10514-010-9205-0
Bosscher PM, Ebert-Uphoff IMME (2004) A stability measure for underconstrained cable-driven robots. In: Proceedings of IEEE international conference on robotics and automation 2004. New Orleans, LA, USA. pp 4943–4949. https://doi.org/10.1109/robot.2004.1302501
Khosravi AM et al (2013) Robust PID control of fully-constrained cable driven parallel robots. Mechatronics 24(2):87–97. https://doi.org/10.1016/j.mechatronics.2013.12.001
Wei HL, Qiu YY, Su Y (2016) Motion control strategy and stability analysis for high-speed cable-driven camera robots with cable inertia effects. Int J Adv Robot Syst 13:1–14. https://doi.org/10.1177/1729881416663374
Wei HL, Qui YY, Wang J (2015) An approach to evaluate stability for cable-based parallel camera robots with hybrid tension-stiffness properties. Int J Adv Robot Syst 12:185. https://doi.org/10.5772/62004
Wei HL, Qui YY, Sheng Y (2019) On the cable pseudo-drag problem of cable-driven parallel camera robots at high speeds. Robotica 37(10):1695–1709. https://doi.org/10.1017/S0263574719000201
Liu P, Qiu YY, Su Y (2016) A new hybrid force-position measure approach on the stability for a camera robot. Proc Inst Mech Eng Part C-J Eng Mech Eng Sci 230(14):2508–2516. https://doi.org/10.1177/0954406215597712
Liu P (2015) On the mechanics and stability for the cable-driven parallel manipulators. Xidian University PhD Thesis
Liu P (2014) Minimum cable tensions for the cable-based parallel robots. J Appl Math 350492:1–8. https://doi.org/10.1155/2014/350492
Wang YL, Zhao ZG, Su C et al (2017) Analysis of the workspace and dynamic stability of a multi-robot collaboratively towing system. J Vib Shock 36(16):44–50. https://doi.org/10.13465/j.cnki.jvs.2017.16.007
Wang YL, Wang KY, Wang WL et al (2019) Appraise and analysis of dynamical stability of cable-driven lower limb rehabilitation training robot. J Mech Sci Tech 33(11):5461–5472. https://doi.org/10.1007/s12206-019-1040-4
Zhao ZG, Wang YL, Li JN (2018) Appraise of dynamical stability of multi-robots cooperatively towing system based on hybrid force-position-pose approach. J Harbin Eng Univ 39(1):148–155. https://doi.org/10.11990/jheu.201608034
Cafolla Daniele, Russo Matteo, Carbone Giuseppe, Cube A (2019) Cable-driven device for limb rehabilitation. J Bionic Eng 16:493–503. https://doi.org/10.1007/s42235-019-0040-5
Liu X, Qiu YY, Sheng Y (2011) Analysis on the static stiffness of wire-driven parallel manipulators. J Mech Eng 47(13):35–43. https://doi.org/10.3901/JME.2011.13.035
Carbone G, Ceccarelli M (2010) Comparison of indices for stiffness performance evaluation. Front Mech Eng China 5(3):270–278. https://doi.org/10.1007/s11465-010-0023-z
Acknowledgements
This work was supported in part by the National Natural Science Foundation of China (51405095), Natural Science Foundation of Heilongjiang Province, China (LH2019E032), and Postdoctoral Scientific Research Fund of Heilongjiang (LBH-Q15030), and Fundamental Research Funds for Central Universities of the Harbin Engineering University (3072019CF0704, 3072020CF0706).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Technical Editor: Adriano Almeida Gonçalves Siqueira.
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Wang, Yl., Wang, Ky. & Zhang, Zx. Design, comprehensive evaluation, and experimental study of a cable-driven parallel robot for lower limb rehabilitation. J Braz. Soc. Mech. Sci. Eng. 42, 371 (2020). https://doi.org/10.1007/s40430-020-02443-x
Received:
Accepted:
Published: