Skip to main content
Log in

Quantitative determination of melatonin in milk by LC-MS/MS

  • Short Communication
  • Published:
Journal of Food Science and Technology Aims and scope Submit manuscript

Abstract

A rapid, reliable and sensitive LC-MS/MS method for the determination of melatonin in milk was developed and validated. Sample was extracted with dichloromethane and cleaned by passing through Chem Elut solid phase extraction cartridge. The solvent was evaporated to dryness, reconstituted with methanol and analysed by LC-MS/MS on Agilent zorbax Eclipse XDB C-18 rapid resolution analytical column. The analytical procedure was found to be accurate, precise and linear. The method accuracy was 92.2 % (range 90.06–94.58) and the mean precision was 1.55 % and the calibration was linear for 1 to 150 pg mL−1 (R2 > 0.99), the lowest limit of quantification (LLOQ) was 1 pg mL−1. 7-D Melatonin (7-DM) was used as an internal standard. This method was proved to be a promising method for the determination of melatonin for market milk and human milk samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

References

  • Anisimov VN, Popovich IG, Zabezhinski MA, Anisimov SV, Vesnushkin GM, Vinogradova IA (2006) Melatonin as antioxidant, geroprotector and anticarcinogen. Biochim Biophys Acta 1757:573–589

    Article  CAS  Google Scholar 

  • Berga SL, Yen SSC (1990) Circadian pattern of plasma melatonin concentrations during four phases of the human menstrual cycle. Neuroendocrinol 51(5):606–612

    Article  CAS  Google Scholar 

  • Cao J, Murch SJ, Brien RO, Saxena PK (2006) Rapid method for accurate analysis of melatonin, serotonin and auxin in plant samples using liquid chromatography-tandem mass spectrometry. J Chromatogr A 1134:333–337

    Article  CAS  Google Scholar 

  • Causon R (1997) validation of chromatographic methods in biomedical analysis viewpoint and discussion. J Chromatogr B 689(1):175–180

    Article  CAS  Google Scholar 

  • Chanut E, Legros JN, Botteri CV, Trouvin JH, Launay JM (1998) Determination of melatonin in rat pineal, plasma and retina by high performance liquid chromatography with electrochemical detection. J Chromatogr B 709(1):11–18

    Article  CAS  Google Scholar 

  • Durden AD (2007) Positive and negative electrospray LC-MS/MS methods for quantitation of the antiparastic endecticide drugs, abamectin, doramectin, emamectin, eprinomectin, ivermectin, moxidectin and selamectin in milk. J Chromatogra B 850:134–146

    Article  CAS  Google Scholar 

  • Egoshi K, Oka T, Yamashita H (2000) Quantitative analysis of melatonin in raw milk by HPLC. Nippon Shokuhin Kagaku Kogaku Kaishi 54(3):113–117

    Article  Google Scholar 

  • Eriksson K, Ostin A, Levin J (2003) Quantification of melatonin in human saliva by liquid chromatography-tandem mass spectrometry using stable isotope dilution. J Chromatogr B 794:115–123

    Article  CAS  Google Scholar 

  • European Commission Decision 2002/657/EC (2002) Off J Eur Commun L221

  • Fourtillan JB, Gobin P, Faye B, Girault J (1994) A highly sensitive assay of melatonin in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry. Biol Mass Spectrom 23(8):499–509

    Article  CAS  Google Scholar 

  • Greiner AC, Chan SC (1978) Melatonin content of the human pineal gland. Science 199:83–84

    Article  CAS  Google Scholar 

  • Heller DN, Peggins JO, Nochetto CB, Smith ML, Chiesa OA, Moulton K (2005) LC-MS/MS measurement of gentamicin in bovine plasma, urine, milk and biopsy samples taken from kidneys of standing animals. J Chromatograph B Analyt Technol Biomed Life Sci 821:22–30

    CAS  Google Scholar 

  • Iinuma F, Hamase K, Matsubayashi S, Takahashi M, Watanabe M, Zaitsu K (1999) Sensitive determination of melatonin by precolumn derivatization and reversed-phase high performance liquid chromatography. J Chromatogr A 835:67–72

    Article  CAS  Google Scholar 

  • Illnerova H, Buresova M, Presl J (1993) Melatonin rhythm in human milk. J Clin Endocrinol Metab 77(3):838–841

    CAS  Google Scholar 

  • Itoh MT, Ishizuka B, Kudo Y, Fusama S, Amemiya A, Sumi Y (1997) Detection of melatonin and serotonin N-acetyltransferase and hydroxyindole-O-methyltransferase activities in rat ovary. Mol Cell Endocrinol 136:7–13

    Article  CAS  Google Scholar 

  • James SP, Sack DA, Rosenthal NE, Mendelson WB (1990) Melatonin administration in insomnia. Neuropsychopharmacol 3(1):19–23

    CAS  Google Scholar 

  • Jan JE, Espezel H (1995) Melatonin treatment of chronic sleep disorders. Dev Med Child Neurol 37(3):279–280

    CAS  Google Scholar 

  • Kennaway DJ, Stamp GE, Goble FC (1992) Development of melatonin production in infants and the impact of prematurity. J Clin Endocrinol Metab 75(2):367–369

    CAS  Google Scholar 

  • Kollmann MT, Locher M, Hirche F, Eder K, Meyer HH, Bruckmaier RM (2008) Effects of tryptophan supplementation on plasma tryptophan and related hormone levels in heifers and dairy cows. Domest Anim Endocrinol 34(1):14–24

    Article  CAS  Google Scholar 

  • Li C, Wu YL, Yang T, Zhang Y (2011) Rapid simultaneous determination of eight benzimidazoles in animal feed by LC-MS/MS. Chromatographia 73:59–65

    Article  CAS  Google Scholar 

  • Lizuka H, Someya K, Yajima T (2007) Hemin-mediated fluorometric determination of melatonin by high-performance liquid chromatography. Int Congr Ser 1304:409–414

    Article  CAS  Google Scholar 

  • Lu J, Lau C, Lee MK, Kai M (2002) Simple and convenient chemiluminescence method for the determination of melatonin. Anal Chim Acta 455(2):193–198

    Article  CAS  Google Scholar 

  • Martinez-Huelamo M, Jimenez-Gamez E, Hermo MP, Barron D, Barbosa J (2009) Determination of pencillins in milk using LC-UV, LC-MS and LC-MS/MS. J Sep Sci 32:2385–2393

    Article  CAS  Google Scholar 

  • Munoz JLP, Ceinos RM, Soengas JL, Miguez JM (2009) A simple and sensitive method for determination of melatonin in plasma, bile and intestinal tissues by high performance liquid chromatography wit fluorescence detection. J Chromatogr B 877:2173–2177

    Article  CAS  Google Scholar 

  • Rizzo V, Porta C, Moroni M, Scoglio E, Moratti R (2002) Determination of free and total (free plus protein bound) melatonin in plasma and cerebrospinal fluid by high-performance liquid chromatography with fluorescence detection. J Chromatogr B 774:17–24

    Article  CAS  Google Scholar 

  • Vitale AA, Ferrari CC, Aldana H, Affanni JM (1996) Highly sensitive method for the determination of melatonin by normal-phase high-performance liquid chromatography with flurometric detection. J Chromatogr B 681(2):381–384

    Article  CAS  Google Scholar 

  • Waldhauser F, Waldhauser M, Lieberman HR, Deng MH, Lynch HJ, Wurtman RJ (1984) Biavailability of oral melatonin in humans. Neuroendocrinol 39:307–313

    Article  CAS  Google Scholar 

  • Zimmerman RC, Schroder S, Baars S, Schumacher M, Weise HC (1990) Melatonin and the ovulatory luteinizing hormone surge. Fertil Steril 54:612–618

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Valsala Madhavan Nair Biju.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Karunanithi, D., Radhakrishna, A., Sivaraman, K.P. et al. Quantitative determination of melatonin in milk by LC-MS/MS. J Food Sci Technol 51, 805–812 (2014). https://doi.org/10.1007/s13197-013-1221-6

Download citation

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13197-013-1221-6

Keywords

Navigation