Accuracy and Precision Comparison for Molecular Weight Distribution Assay of Fish Collagen Peptides: a Methodology Study Between Two Gel Permeation Chromatography Columns

  • Published:
Food Analytical Methods Aims and scope Submit manuscript

Abstract

Two gel permeation chromatography columns, Superdex Peptide HR 10/30 column and TSK G2000 SWXL column, were compared for their accuracy and precision for determining the molecular weight distribution of fish collagen peptides using methodology study. To confirm the results, collagen peptides were subjected to ultrafiltration separation and then the filtrates (MW < 3 kDa) were loaded to MALDI-TOF-MS. Superdex column was consider as the most promising candidate for the determination of small molecular weight peptides (MW < 3 kDa), since it spiked recovery was 101.90% and the RSD was below 1%. As for TSK column, it was more suitable for the assay of large molecular weight peptides (MW > 10 kDa). The spiked recovery was 105.66% and the RSD was below 0.5%. Besides, acetonitrile reagent narrowed the pore size distribution of column packing materials, which made it more inaccurate for the analysis of smaller molecular weight peptides.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

Download references

Acknowledgements

This study is supported by the National Natural Science Foundation of China [No. 31671804], Guangdong Special Funding for Outstanding Young Scholars [2014TQ01N645], Guangdong Science and Technology Planning Project [2017B090901063 and 2015B020230001], Science and Technology Program of Guangzhou [201604020047], the Fundamental Research Funds for the Central Universities [017ZD079], and the 111 Project [B17018].

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jiaoyan Ren.

Ethics declarations

Conflict of Interest

Xiaoling Lin declares that she has no conflict of interest. Yunjun Lu declares that she has no conflict of interest. Ting Zhang declares that she has no conflict of interest. Ming Liang declares that she has no conflict of interest. Yueyan Cen declares that she has no conflict of interest. Erdong Yuan declares that she has no conflict of interest. Jiaoyan Ren declares that she has no conflict of interest.

Ethical Approval

This article does not contain any studies with human or animal subjects by any of the authors.

Informed Consent

Not applicable.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lin, X., Lu, Y., Zhang, T. et al. Accuracy and Precision Comparison for Molecular Weight Distribution Assay of Fish Collagen Peptides: a Methodology Study Between Two Gel Permeation Chromatography Columns. Food Anal. Methods 12, 246–257 (2019). https://doi.org/10.1007/s12161-018-1356-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12161-018-1356-1

Keywords

Navigation