Abstract
The viscoelastic multi-dimensional earthquake isolation and mitigation device is a new kind of passive control device, which has both earthquake isolation and earthquake mitigation abilities. In order to quantify the horizontal earthquake isolation and mitigation effect of this device on structures, shaking table tests on structures with and without the devices and the corresponding analysis on earthquake isolation and mitigation properties are carried out. It can be shown from the experimental and analytical results that the device has both earthquake isolation and earthquake mitigation effects on structures in horizontal direction, and its horizontal earthquake mitigation coefficients can be referred to those of the rubber bearing earthquake isolation structure.
Similar content being viewed by others
References
Mokha A S, Lee P L, Wang X, et al. Seismic isolation design of the new international terminal at San Francisco International Airport. In: Proc Struct Cong. New Orleans: ASCE, 1999. 95–98
Shi W X, Sun H S, Li Z G. High position seismic isolation of press center at Shanghai International Circuit (in Chinese). J Tongji Univ (Nat Sci), 2005, 33(12): 1576–1580
Xu Z D, Zhao H T, Li A Q. Optimal analysis and experimental study on structures with viscoelastic dampers. J Sound Vibr, 2004, 273(3): 607–618
Robert J M, Douglas P T. Fluid viscous dampers for high-rise buildings. Struct Design Tall Spec Bldg, 2003, 12(2): 134–154
Xu Z D, Guo Y Q. Integrated intelligent control analysis on semiactive structures by using magnetorheological dampers. Sci China Ser E-Tech Sci, 2008, 51(12): 2280–2294
Xue S D, Zhou Q. Design and earthquake isolation performance of SMA-rubber combined device (in Chinese). World Earthq Eng, 2003, 19(4): 34–38
Qu W L, Zhou Q, Su J Y, et al. Intelligent combined earthquake isolation control for horizontal shear torsion and vertical earthquake responses of multi-story buildings (in Chinese). Earthq Eng Eng Dyn, 2003, 23(5): 187–195
Clough R, Penzien J. Dynamics of Structures. New York: Computers and Structures Inc., 2003
National Standard committee of the People’s Republic of China. National Standard of the People’s Republic of China: Code for Seismic Design of Buildings (GB 5001 2001). Beijing: China Architecture & Building Press, 2001
Xu Z D. Report of experimental study on the multi-dimensional earthquake isolation and mitigation devices (in Chinese). Nanjing: Southeast University, 2006
Tang J X. Design on earthquake isolation and mitigation for structures (in Chinese). Arch Sci, 2002, 18(1): 21–44
Chopra A K. Dynamics of Structures: Theory and applications to earthquake engineering (2nd Edition). New Jersey: Prentice Hall, 2000
Author information
Authors and Affiliations
Corresponding author
Additional information
Supported by the National Natural Science Foundation of China (Grant No. 50508010), the Jiangsu Province Natural Science Foundation (Grant No. BK2008282), the Program for New Century Excellent Talents of the Ministry of Education in China, the Program for Jiangsu Province 333 Talents and the Project-sponsored by SRF for ROCS, SEM
Rights and permissions
About this article
Cite this article
Xu, Z., Zeng, X., Wu, K. et al. Horizontal shaking table tests and analysis on structures with multi-dimensional earthquake isolation and mitigation devices. Sci. China Ser. E-Technol. Sci. 52, 2009–2016 (2009). https://doi.org/10.1007/s11431-009-0149-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11431-009-0149-6