Abstract
The current utilization of positron emission tomography (PET) imaging is limited due to the high costs associated with production facility start-up and operations; subsequently, there has been a movement towards microfluidic synthesis of radiolabeled imaging pharmaceuticals (tracers). In this review, we summarize the current status of microfluidic radiosynthesis units for producing fluorine-18 labeled PET imaging tracers, including a discussion of the relative strengths and weaknesses of such devices. In addition, we provide a brief overview of the radiotracers that have been produced using microfluidic devices to date. Finally, we discuss the prospects for the future of this field, including the potential of newly envisioned devices developed that may allow operators to easily synthesize specialized tracers for individual patient doses.
Similar content being viewed by others
References
Wang M-W, Lin W-Y, Liu K et al (2010) Microfluidics for positron emission tomography probe development. Mol Imaging 9:175–191
Elizarov AM (2009) Microreactors for radiopharmaceutical synthesis. Lab Chip 9:1326. https://doi.org/10.1039/b820299k
Fortt R, Gee AD (2013) Microfluidics: a golden opportunity for positron emission tomography? Future Med Chem 5:241–244
Shen CK-F (2011) Microfluidic-assisted radiochemistry and PET probe synthesis. MI Gatew 5:1–5
Watts P, Pascali G, Salvadori PA (2012) Positron emission tomography radiosynthesis in microreactors. J Flow Chem 2:37–42
Audrain H (2007) Positron emission tomography (PET) and microfluidic devices: a breakthrough on the microscale? Angew Chemie - Int Ed 46:1772–1775
Pascali G, Watts P, Salvadori PA (2013) Microfluidics in radiopharmaceutical chemistry. Nucl Med Biol 40:776–787
Miller PW (2009) Radiolabelling with short-lived PET (positron emission tomography) isotopes using microfluidic reactors. J Chem Technol Biotechnol 84:309–315
Rensch C, Jackson A, Lindner S, Salvamoser R, Samper V, Riese S, Bartenstein P, Wängler C, Wängler B (2013) Microfluidics: a groundbreaking technology for PET tracer production? Molecules 18:7930–7956
Keng P-Y, Esterby M, van Dam RM (2012) Emerging technologies for decentralized production of PET tracers. In: Hsieh C-H (ed) Positron emission tomography - current clinical and research aspects. Rijeka, InTech, pp 153–182
Rensch C, Lindner S, Salvamoser R, Leidner S, Böld C, Samper V, Taylor D, Baller M, Riese S, Bartenstein P, Wängler C, Wängler B (2014) A solvent resistant lab-on-chip platform for radiochemistry applications. Lab Chip 14:2556–2564
Zhang X, Liu F, Knapp K-A, Nickels ML, Manning HC, Bellan LM (2018) A simple microfluidic platform for rapid and efficient production of the radiotracer [18F]fallypride. Lab Chip 18:1369–1377
Matesic L, Kallinen A, Greguric I, Pascali G (2017) Dose-on-demand production of diverse 18 F-radiotracers for preclinical applications using a continuous flow microfluidic system. Nucl Med Biol 52:24–31
Lu S-Y, Pike VW (2010) Synthesis of [18F]xenon difluoride as a radiolabeling reagent from [18F]fluoride ion in a micro-reactor and at production scale. J Fluor Chem 131:1032–1038
Zacheo A, Arima V, Pascali G et al (2011) Radioactivity resistance evaluation of polymeric materials for application in radiopharmaceutical production at microscale. Microfluid Nanofluidics 11:35–44
Ungersboeck J, Philippe C, Mien LK et al (2011) Microfluidic preparation of [18F]FE@SUPPY and [18F]FE@SUPPY:2 - comparison with conventional radiosyntheses. Nucl Med Biol 38:427–434
Lu S-Y, Watts P, Chin FT, Hong J, Musachio JL, Briard E, Pike VW (2004) Syntheses of 11C- and 18F-labeled carboxylic esters within a hydrodynamically-driven micro-reactor. Lab Chip 4:523. https://doi.org/10.1039/b407938h
Gillies JM, Prenant C, Chimon GN, Smethurst GJ, Dekker BA, Zweit J (2006) Microfluidic technology for PET radiochemistry. Appl Radiat Isot 64:333–336
Zizzari A, Arima V, Zacheo A, Pascali G, Salvadori PA, Perrone E, Mangiullo D, Rinaldi R (2011) Fabrication of SU-8 microreactors for radiopharmaceutical production. Microelectron Eng 88:1664–1667
Wester H-J, Schoultz BW, Hultsch C, Henriksen G (2009) Fast and repetitive in-capillary production of [18F]FDG. Eur J Nucl Med Mol Imaging 36:653–658
Lee C-C, Sui G, Elizarov AM et al (2005) Multistep synthesis of a radiolabeled imaging probe using integrated microfluidics. Science 310:1793–1796
Maltezos G, Garcia E, Hanrahan G, Gomez FA, Vyawhare S, van Dam RM, Chen Y, Scherer A (2007) Design and fabrication of chemically robust three-dimensional microfluidic valves. Lab Chip 7:1209. https://doi.org/10.1039/b705031c
Keng P-Y, Chen S, Ding H, Sadeghi S, Shah GJ, Dooraghi A, Phelps ME, Satyamurthy N, Chatziioannou AF, Kim CJC, van Dam RM (2012) Micro-chemical synthesis of molecular probes on an electronic microfluidic device. Proc Natl Acad Sci U S A 109:690–695
De Leonardis F, Pascali G, Salvadori PA et al (2011) On-chip pre-concentration and complexation of [18F]fluoride ions via regenerable anion exchange particles for radiochemical synthesis of positron emission tomography tracers. J Chromatogr A 1218:4714–4719
Oh JH, Lee BN, Nam KR et al (2011) Design features of microfluidic reactor for [18F]FDG radiopharmaceutical synthesis. AIP Conf Proc 1336. https://doi.org/10.1063/1.3586135
Saiki H, Iwata R, Nakanishi H, Wong R, Ishikawa Y, Furumoto S, Yamahara R, Sakamoto K, Ozeki E (2010) Electrochemical concentration of no-carrier-added [18F]fluoride from [18O]water in a disposable microfluidic cell for radiosynthesis of 18F-labeled radiopharmaceuticals. Appl Radiat Isot 68:1703–1708
Ungersboeck J, Richter S, Collier L, Mitterhauser M, Karanikas G, Lanzenberger R, Dudczak R, Wadsak W (2012) Radiolabeling of [18F]altanserin — a microfluidic approach. Nucl Med Biol 39:1087–1092
Anderson H, Pillarsetty N, Cantorias M, Lewis JS (2010) Improved synthesis of 2′-deoxy-2′-[18F]-fluoro-1-β-d-arabinofuranosyl-5-iodouracil ([18F]-FIAU). Nucl Med Biol 37:439–442
Salvador B, Luque A, Fernandez-Maza L, Corral A, Orta D, Fernandez I, Quero JM (2017) Disposable PDMS chip with integrated [18F]fluoride pre-concentration cartridge for radiopharmaceuticals. J Microelectromech Syst 26:1442–1448
Salvador B, Luque A, Quero JM, et al. (2017) Integrated anion-exchange cartridge for [18F]F-preconcentration in a PDMS radiopharmacy chip. In: 2017 Spanish conference on electron devices (CDE). IEEE, pp 1–4
Sadeghi S, Ly J, Deng Y, Van Dam RM (2010) A robust platinum-based electrochemical micro flow cell for drying of [18F]fluoride for pet tracer synthesis. In: 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010. pp 318–320
Lu S, Clements JT, Gilde MJ, Prak A, Watts P, Pike VW (2007) Separation of [18F]fluoride ion from proton-irradiated [18O]water within an EOF-driven micro-reactor powered by the Capilix Capella™ platform. J Label Compd Radiopharm 50:597–599
Tseng W-Y, Cho J, Ma X, et al. (2010) PDMS evaporation chip to concentrate [18F] fluoride for synthesis of PET tracers in microfluidics. In: 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences. Pp 1010–1012
Elizarov AM, van Dam RM, Shin Y-S, Kolb HC, Padgett HC, Stout D, Shu J, Huang J, Daridon A, Heath JR (2010) Design and optimization of coin-shaped microreactor chips for PET radiopharmaceutical synthesis. J Nucl Med 51:282–287
Tseng W-Y, Cho J, Ma X et al (2010) Toward reliable synthesis of radiotracers for positron emission tomography in PDMS microfluidic chips: study and optimization of the [18F] fluoride drying process. NSTI Nanotechnol Conf Expo 2:472–475
Cvetković BZ, Lade O, Marra L, Arima V, Rinaldi R, Dittrich PS (2012) Nitrogen supported solvent evaporation using continuous-flow microfluidics. RSC Adv 2:11117
Wong R, Iwata R, Saiki H, Furumoto S, Ishikawa Y, Ozeki E (2012) Reactivity of electrochemically concentrated anhydrous [18F]fluoride for microfluidic radiosynthesis of 18F-labeled compounds. Appl Radiat Isot 70:193–199
Chen S, Javed MR, Kim H-K, Lei J, Lazari M, Shah GJ, van Dam RM, Keng PY, Kim CJ“CJ” (2014) Radiolabelling diverse positron emission tomography (PET) tracers using a single digital microfluidic reactor chip. Lab Chip 14:902–910
Rensch C, Wängler B, Yaroshenko A et al (2012) Autoradiolysis suppression in microfluidic channels. J Nucl Med 53:574
Bejot R, Elizarov AM, Ball E, Zhang J, Miraghaie R, Kolb HC, Gouverneur V (2011) Batch-mode microfluidic radiosynthesis of N-succinimidyl-4-[18F]fluorobenzoate for protein labelling. J Label Compd Radiopharm 54:117–122
Keng P-Y, van Dam RM (2015) Digital microfluidics: a new paradigm for radiochemistry. Mol Imaging 14:13–14
Steel C, O’Brien AT, Luthra SK, Brady F (2007) Automated PET radiosyntheses using microfluidic devices. J Label Compd Radiopharm 50:308–311
Lebedev A, Miraghaie R, Kotta K, Ball CE, Zhang J, Buchsbaum MS, Kolb HC, Elizarov A (2013) Batch-reactor microfluidic device: first human use of a microfluidically produced PET radiotracer. Lab Chip 13:136–145
Zheng M-Q, Collier TL, Bois F et al (2015) Synthesis of [18F]FMISO in a flow-through microfluidic reactor: development and clinical application. Nucl Med Biol 42:578–584
Arima V, Pascali G, Lade O, Kretschmer HR, Bernsdorf I, Hammond V, Watts P, de Leonardis F, Tarn MD, Pamme N, Cvetkovic BZ, Dittrich PS, Vasovic N, Duane R, Jaksic A, Zacheo A, Zizzari A, Marra L, Perrone E, Salvadori PA, Rinaldi R (2013) Radiochemistry on chip: towards dose-on-demand synthesis of PET radiopharmaceuticals. Lab Chip 13:2328
Yokell DL, Leece AK, Lebedev A, Miraghaie R, Ball CE, Zhang J, Kolb H, Elizarov A, Mahmood U (2012) Microfluidic single vessel production of hypoxia tracer 1H-1-(3-[18F]-fluoro-2-hydroxy-propyl)-2-nitro-imidazole ([18F]-FMISO). Appl Radiat Isot 70:2313–2316
Liu K, Lepin EJ, Wang M-W et al (2011) Microfluidic-based 18F-labeling of biomolecules for immuno-positron emission tomography. Mol Imaging 10(168–76):1–7
Ding H, Sadeghi S, Shah GJ, Chen S, Keng PY, Kim CJ“CJ”, van Dam RM (2012) Accurate dispensing of volatile reagents on demand for chemical reactions in EWOD chips. Lab Chip 12:3331–3340
Wang J, Chao PH, Hanet S, van Dam RM (2017) Performing multi-step chemical reactions in microliter-sized droplets by leveraging a simple passive transport mechanism. Lab Chip 17:4342–4355
Sergeev M, Lazari M, Morgia F, Collins J, Javed MR, Sergeeva O, Jones J, Phelps ME, Lee JT, Keng PY, van Dam RM (2018) Performing radiosynthesis in microvolumes to maximize molar activity of tracers for positron emission tomography. Commun Chem 1:10
Shah GJ, Tata U, van Dam RM (2014) Automation and interfaces for chemistry and biochemistry in digital microfluidics. TECHNOLOGY 02:83–100
Wang H, Chen L, Sun L (2017) Digital microfluidics: a promising technique for biochemical applications. Front Mech Eng 12:510–525
Fiel SA, Yang H, Schaffer P, Weng S, Inkster JAH, Wong MCK, Li PCH (2015) Magnetic droplet microfluidics as a platform for the concentration of [18F]fluoride and radiosynthesis of sulfonyl [18F]fluoride. ACS Appl Mater Interfaces 7:12923–12929
De Leonardis F, Pascali G, Salvadori PA, et al. (2010) Microfluidic modules for [18F-] activation - towards an integrated modular lab on a chip for pet radiotracer synthesis. In: 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010. pp 1604–1606
Kimura H, Tomatsu K, Saiki H, Arimitsu K, Ono M, Kawashima H, Iwata R, Nakanishi H, Ozeki E, Kuge Y, Saji H (2016) Continuous-flow synthesis of N-succinimidyl 4-[18F]fluorobenzoate using a single microfluidic chip. PLoS One 11:e0159303
Javed MR, Chen S, Kim H-K, Wei L, Czernin J, Kim CJC, Michael van Dam R, Keng PY (2014) Efficient radiosynthesis of 3′-deoxy-3′-18F-fluorothymidine using electrowetting-on-dielectric digital microfluidic chip. J Nucl Med 55:321–328
Tarn MD, Pascali G, De Leonardis F et al (2013) Purification of 2-[18F]fluoro-2-deoxy-d-glucose by on-chip solid-phase extraction. J Chromatogr A 1280:117–121
Tseng W-Y, van Dam RM (2014) Compact microfluidic device for rapid concentration of PET tracers. Lab Chip 14:2293–2302
Chao PH, Collins J, Argus JP, Tseng WY, Lee JT, Michael van Dam R (2017) Automatic concentration and reformulation of PET tracers via microfluidic membrane distillation. Lab Chip 17:1802–1816
Lu S-Y, Giamis AM, Pike VW (2009) Synthesis of [18F]fallypride in a micro-reactor: rapid optimization and multiple-production in small doses for micro-PET studies. Curr Radiopharm 2:nihpa81093
Cho J, Taschereau R, Olma S et al (2009) Cerenkov radiation imaging as a method for quantitative measurements of beta particles in a microfluidic chip. Phys Med Biol 54:6757–6771
Taggart MP, Tarn MD, Esfahani MMN, Schofield DM, Brown NJ, Archibald SJ, Deakin T, Pamme N, Thompson LF (2016) Development of radiodetection systems towards miniaturised quality control of PET and SPECT radiopharmaceuticals. Lab Chip 16:1605–1616
Taggart MP, Tarn MD, Esfahani MMN, et al. (2015) On-chip detection of radioactivity via silicon-based sensors for the quality control testing of radiopharmaceuticals. 19th Int Conf Miniaturized Syst Chem Life Sci 1849–1851
Cheung S, Ly J, Lazari M, Sadeghi S, Keng PY, van Dam RM (2014) The separation and detection of PET tracers via capillary electrophoresis for chemical identity and purity analysis. J Pharm Biomed Anal 94:12–18
Ha NS, Ly J, Jones J, Cheung S, van Dam RM (2017) Novel volumetric method for highly repeatable injection in microchip electrophoresis. Anal Chim Acta 985:129–140. https://doi.org/10.1016/j.aca.2017.05.037
Ly J, Ha NS, Cheung S, van Dam RM (2018) Toward miniaturized analysis of chemical identity and purity of radiopharmaceuticals via microchip electrophoresis. Anal Bioanal Chem 410:2423–2436. https://doi.org/10.1007/s00216-018-0924-y
Tarn MD, Brown NJ, Pamme N, Archibald SJ (2015) Integrated microfluidic radiotracer quality control: miniaturised on-chip absorbance spectroscopy. J Label Compd Radiopharm 58:S20
Tarn MD, Esfahani MMN, Patinglag L, et al (2017) Microanalytical devices towards integrated quality control testing of [18F] FDG radiotracer. 559–560
Tarn MD, Kızılyer NY, Esfahani MMN, et al (2018) Plastic scintillator-based microfluidic devices for miniaturized detection of positron emission tomography radiopharmaceuticals. Chem - A Eur J 1–6
Ha N, Sadeghi S, van Dam R (2017) Recent progress toward microfluidic quality control testing of radiopharmaceuticals. Micromachines 8:337
Pascali G, Nannavecchia G, Pitzianti S, Salvadori PA (2011) Dose-on-demand of diverse 18F-fluorocholine derivatives through a two-step microfluidic approach. Nucl Med Biol 38:637–644
Telu S, Chun J-H, Siméon FG, Lu S, Pike VW (2011) Syntheses of mGluR5 PET radioligands through the radiofluorination of diaryliodonium tosylates. Org Biomol Chem 9:6629
Pascali G, Pitzianti S, Saccomanni G et al (2011) Initial studies on the effect of water in microfluidic radiofluorinations. J Label Compd Radiopharm S502
Chun J-H, Lu S-Y, Pike VW (2011) Rapid and efficient radiosyntheses of meta-substituted [18F]fluoroarenes from [18F]fluoride ion and diaryliodonium tosylates within a microreactor. European J Org Chem 2011:4439–4447
Bouvet VR, Wuest M, Tam P-H, Wang M, Wuest F (2012) Microfluidic technology: an economical and versatile approach for the synthesis of O-(2-[18F]fluoroethyl)-L-tyrosine ([18]FET). Bioorg Med Chem Lett 22:2291–2295
Selivanova SV, Mu L, Ungersboeck J, Stellfeld T, Ametamey SM, Schibli R, Wadsak W (2012) Single-step radiofluorination of peptides using continuous flow microreactor. Org Biomol Chem 10:3871
Akula MR, Collier TL, Kabalka GW (2012) Automated microfluidic synthesis of [F-18]FSB. J Nucl Med 53:576
Cumming R, Knight L, Sutcliffe J (2012) Fluorine-18 radiolabeling of peptides using a microfluidic flow chemistry device. J Nucl Med 53:573
Richter S, Bouvet VR, Wuest M, Bergmann R, Steinbach J, Pietzsch J, Neundorf I, Wuest F (2012) 18F-labeled phosphopeptide-cell-penetrating peptide dimers with enhanced cell uptake properties in human cancer cells. Nucl Med Biol 39:1202–1212
Chun J-H, Pike VW (2012) Selective syntheses of no-carrier-added 2- and 3-[18F]fluorohalopyridines through the radiofluorination of halopyridinyl(4′-methoxyphenyl)iodonium tosylates. Chem Commun 48:9921
Dahl K, Schou M, Halldin C (2012) Radiofluorination and reductive amination using a microfluidic device. J Label Compd Radiopharm 55:455–459
Dewkar GK, Sundaresan G, Lamichhane N, Hirsch J, Thadigiri C, Collier T, Hartman MCT, Vaidyanthan G, Zweit J (2013) Microfluidic radiosynthesis and biodistribution of [18F] 2-(5-fluoro-pentyl)-2-methyl malonic acid. J Label Compd Radiopharm 56:289–294
Liang SH, Collier TL, Rotstein BH, Lewis R, Steck M, Vasdev N (2013) Rapid microfluidic flow hydrogenation for reduction or deprotection of 18F-labeled compounds. Chem Commun 49:8755–8757
Liang SH, Yokell DL, Jackson RN, Rice PA, Callahan R, Johnson KA, Alagille D, Tamagnan G, Lee Collier T, Vasdev N (2014) Microfluidic continuous-flow radiosynthesis of [ 18 F]FPEB suitable for human PET imaging. Med Chem Commun 5:432–435
Cheung Y-Y, Nickels ML, Tang D, Buck JR, Manning HC (2014) Facile synthesis of SSR180575 and discovery of 7-chloro-N,N,5-trimethyl-4-oxo-3(6-[18F]fluoropyridin-2-yl)-3,5-dihydro-4 H-pyridazino[4,5-b]indole-1-acetamide, a potent pyridazinoindole ligand for PET imaging of TSPO in cancer. Bioorg Med Chem Lett 24:4466–4471
Liang SH, Yokell DL, Normandin MD, et al. (2014) First human use of a radiopharmaceutical prepared by continuous-flow microfluidic radiofluorination: proof of concept with the tau imaging agent [18F]T807. Mol Imaging 13:
Calderwood S, Collier TL, Gouverneur V, Liang SH, Vasdev N (2015) Synthesis of 18F-arenes from spirocyclic iodonium(III) ylides via continuous-flow microfluidics. J Fluor Chem 178:249–253
Philippe C, Haeusler D, Scherer T et al (2016) [18F]FE@SNAP—a specific PET tracer for melanin-concentrating hormone receptor 1 imaging? EJNMMI Res 6:31
Collier TL, Liang SH, Mann JJ, Vasdev N, Kumar JSD (2017) Microfluidic radiosynthesis of [18F]FEMPT, a high affinity PET radiotracer for imaging serotonin receptors. Beilstein J Org Chem 13:2922–2927
Zhang B, Pascali G, Wyatt N, Matesic L, Klenner MA, Sia TR, Guastella AJ, Massi M, Robinson AJ, Fraser BH (2018) Synthesis, bioconjugation and stability studies of [18F]ethenesulfonyl fluoride. J Label Compd Radiopharm 61:847–856
Matesic L, Greguric I, Pascali G (2018) Microfluidic radiosynthesis of the muscarinic M2 imaging agent [18F]FP-TZTP*. Aust J Chem
Briard E, Zoghbi SS, Siméon FG et al (2009) Single-step high-yield radiosynthesis and evaluation of a sensitive 18F-labeled ligand for imaging brain peripheral benzodiazepine receptors with PET. J Med Chem 52:688–699
Chun J-H, Lu S-Y, Lee Y-S, Pike VW (2010) Fast and high-yield microreactor syntheses of ortho-substituted [18F]fluoroarenes from reactions of [18F]fluoride ion with diaryliodonium salts. J Org Chem 75:3332–3338
Pascali G, Mazzone G, Saccomanni G, Manera C, Salvadori PA (2010) Microfluidic approach for fast labeling optimization and dose-on-demand implementation. Nucl Med Biol 37:547–555
Bouvet VR, Wuest M, Wiebe LI, Wuest F (2011) Synthesis of hypoxia imaging agent 1-(5-deoxy-5-fluoro-α-d-arabinofuranosyl)-2-nitroimidazole using microfluidic technology. Nucl Med Biol 38:235–245
Pascali G, Berton A, DeSimone M, Wyatt N, Matesic L, Greguric I, Salvadori PA (2014) Hardware and software modifications on the Advion NanoTek microfluidic platform to extend flexibility for radiochemical synthesis. Appl Radiat Isot 84:40–47
Liu Y, Tian M, Zhang H (2013) Microfluidics for synthesis of peptide-based pet tracers. Biomed Res Int 2013:839683
Javed MR, Chen S, Lei J, Collins J, Sergeev M, Kim HK, Kim CJ, van Dam RM, Keng PY (2014) High yield and high specific activity synthesis of [18F]fallypride in a batch microfluidic reactor for micro-PET imaging. Chem Commun 50:1192–1194
Pascali G, Matesic L (2016) How far are we from dose on demand of short-lived radiopharmaceuticals? In: Kuge Y, Shiga T, Tamaki N (eds) Perspectives on nuclear medicine for molecular diagnosis and integrated therapy. Springer Japan, Tokyo, pp 79–92
Funding
This project was supported using funding from the Vanderbilt University Trans-Institutional Program (TIPs), Vanderbilt-Ingram Cancer Center (VICC), and Vanderbilt Center for Molecular Probes (CMP).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic Supplementary Material
ESM 1
(DOCX 81.8 kb)
Rights and permissions
About this article
Cite this article
Knapp, KA., Nickels, M.L. & Manning, H.C. The Current Role of Microfluidics in Radiofluorination Chemistry. Mol Imaging Biol 22, 463–475 (2020). https://doi.org/10.1007/s11307-019-01414-6
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11307-019-01414-6