Skip to main content

Advertisement

Log in

Joining characteristics of titanium-based orthodontic wires connected by laser and electrical welding methods

  • Clinical Applications of Biomaterials
  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

This study investigated the possibility of electrical and laser welding to connect titanium-based alloy (beta-titanium and nickel-titanium) wires and stainless-steel or cobalt-chromium alloy wires for fabrication of combination arch-wires. Four kinds of straight orthodontic rectangular wires (0.017 × 0.025 inch) were used: stainless-steel (S-S), cobalt-chromium (Co-Cr), beta-titanium alloy (β-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (15 mm long each) were made by electrical welding and laser welding. Non-welded wires (30 mm long) were also used as a control. Maximum loads at fracture (N) and elongation (%) were measured by conducting tensile test. The data (n = 10) were statistically analyzed using analysis of variance/Tukey test (P < 0.05).The S-S/S-S and Co-Cr/Co-Cr specimens showed significantly higher values of the maximum load (ML) at fracture and elongation (EL) than those of the Ni-Ti/Ni-Ti and β-Ti/β-Ti specimens for electrical welding and those of the S-S/S-S and Co-Cr/Co-Cr specimens welded by laser. On the other hand, the laser-welded Ni-Ti/Ni-Ti and β-Ti/β-Ti specimens exhibited higher values of the ML and EL compared to those of the corresponding specimens welded by electrical method. In the heterogeneously welded combinations, the electrically welded Ni-Ti/S-S, β-Ti/S-S and β-Ti/Co-Cr specimens showed significantly (P < 0.05) higher ML and EL than those of the corresponding specimens welded by laser. Electrical welding exhibited the higher values of maximum load at fracture and elongation for heterogeneously welded combinations than laser-welding.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Asgharnia MK, Brantley WA. Comparison of bending and tension tests for orthodontic wires. Am J Orthod. 1986;89:228–36.

    Article  Google Scholar 

  2. Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Othod. 1989;96:100–9.

    Article  Google Scholar 

  3. Krishnan V, Kumar KJ. Mechanical properties and surface characteristics of three archwire alloys. Angle Orthod. 2004;74:825–31.

    Google Scholar 

  4. Tian K, Darvell BW. Determination of the flexural of elasticity of orthodontic archwires. Dent Mater. 2010;26:821–9.

    Article  Google Scholar 

  5. Fillmore GM, Tomlinson JL. Heat treatment of cobalt-chromium alloy wire. Angle Orthod. 1976;46:2.

    Google Scholar 

  6. Bock JJ, Fraenzel W, Bailly J, Gernhardt CR, Fuhrmann RAW. Infuence of different brazing and welding methods on tensile strength and microhardness of orthodontic stainless steel wire. Eur J Orthod. 2008;30:396–400.

    Article  Google Scholar 

  7. Bock JJ, Bailly J, Gernhardt CR, Fuhrmann AW. Fracture strength of different soldered and welded orthodontic joining configurations with and without filling material. J Appl Oral Sci. 2008;16(5):328–35.

    Article  Google Scholar 

  8. Miura F, Mogi M, Ohura Y, Hamanaka H. The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics. Am J Orthod. 1986;90:1–10.

    Article  Google Scholar 

  9. Gurgel JA, Pinzan-Vercelino RM, Powers JM. Mechanical properties of beta-titanium wires. Angle Orthod. 2011;81:478–83.

    Article  Google Scholar 

  10. Johnson E. Relative stiffness of beta titanium archwires. Angle Orthod. 2003;73:259–69.

    Google Scholar 

  11. Yonekura Y, Endo K, Iijima M, Ohno H, Mizoguchi I. In vitoro corrosion characteristics of commercially available orthodontic wires. Dent Mater J. 2004;23:197–202.

    Article  Google Scholar 

  12. Watanabe I, Watkins JH, Nakajima H, Atsuta M, Okabe T. Effect of pressure difference on the quality of titanium casting. J Dent Res. 1997;76:773–9.

    Article  Google Scholar 

  13. Wang RR, Welsch GH. Joining titanium materials with tungsten inert gas welding, laser welding, and infrared brazing. J Prosthet Dent. 1995;74:521–30.

    Article  Google Scholar 

  14. Iijima M, Brantley WA, Yuasa T, Kawashima I, Mizoguchi I. Joining characteristics of beta-titanium wires with electrical resistance welding. J Biomed Mater Res B. 2008;85:378–84.

    Article  Google Scholar 

  15. Nascimento LEA, Santos RL, Pithon MM, Souza Araujo MT, Nojima MT, Nojima LI. The effect of spot-welding on the mechanical properties of different orthodontic wire alloys. Mater Res. 2012;15(3):409–14.

    Article  Google Scholar 

  16. Sevilla P, Martorell F, Libenson C, Planell JA, Gil FJ. Laser welding of NiTi orthodontic archwires for selective force application. J Mater Sci Mater Med. 2008;19:525–9.

    Article  Google Scholar 

  17. Iijima M, Brantley WA, Yuasa T, Muguruma T, Kawashima I, Mizoguchi I. Joining characteristics of orthodontic wires with laser welding. J Biomed Mater Res. 2008;84B:147–53.

    Article  Google Scholar 

  18. Watanabe E, Stigall G, Elshahawy W, Watanabe I. Deflection load characteristics of laser-welded orthodontic wires. Angle Orthod. 2012;82:698–702.

    Article  Google Scholar 

  19. Baba N, Watanabe I, Tanaka Y, Hisatsune K, Atsuta M. Joint properties of cast Fe-Pt magnetic alloy laser-welded to Co-Cr alloys. Dent Mater J. 2005;24:550–4.

    Article  Google Scholar 

  20. Watanabe I, Nguyen K, Benson PA, Tanaka Y. Joint properties of cast Fe-Pt magnetic alloy laser-welded to Au-and Ag-alloys. J Biomed Mater Res. 2006;76B:190–5.

    Article  Google Scholar 

  21. Quintino L, Miranda RM. Welding shape memory alloys with NdYAG lasers. Soldag e Insp. 2012;17(3):210–7.

    Article  Google Scholar 

  22. Chatterjee S, Abinandanan TA, Chattopadhyay K. Phase formation in Ti/Ni dissimilar welds. Mater Sci Eng A. 2008;490:7–15.

    Article  Google Scholar 

  23. Chatterjee S, Abinandanan TA, Chattopadhyay K. Microstructure Development during Dissimilar Welding: case of Laser Welding of Ti with Ni involving Intermetallic Phase Formation. J Mater Sci. 2006;41:643–52.

    Article  Google Scholar 

Download references

Acknowledgments

This study was partially supported by a Grant MEXT KAKENHI Grant No. 23659905.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ikuya Watanabe.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Matsunaga, J., Watanabe, I., Nakao, N. et al. Joining characteristics of titanium-based orthodontic wires connected by laser and electrical welding methods. J Mater Sci: Mater Med 26, 50 (2015). https://doi.org/10.1007/s10856-015-5391-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10856-015-5391-9

Keywords

Navigation