Skip to main content

Advertisement

Log in

Outcomes of adjustable strabismus surgery in an Irish University Hospital

  • Original Paper
  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose

Strabismus surgery aims to improve binocular vision, reduce diplopia, and enhance cosmesis. Adjustable strabismus procedures have been developed as a means of tackling unpredictability in some post-operative results. The purpose of the study was to compare the effectiveness of adjustable and non-adjustable squint procedures in the treatment of strabismus.

Methods

We analyzed adjustable or non-adjustable squint surgery undergone in our Irish locality by retrospectively studying 27 consecutive patients at Mater Misericordiae University Hospital, Dublin.

Results

There was no significant difference (p = 0.519) in the mean post-operative horizontal deviation between the adjustable group (mean = 11.6 PD) and the non-adjustable group (mean = 15.3 PD). We found that adjustable procedures resulted in a trend (p = 0.050) towards a greater mean horizontal effect per muscle (18.9 PD per muscle) than non-adjustable procedures (mean 9.7 PD). We went on to analyze the adjustable group in order to determine the impact on outcome in those patients in whom their adjustable sutures were manipulated postoperatively. Of the 11 patients who underwent adjustable procedures, 6 subsequently had adjustments made as planned and 5 did not require adjustment. Those patients who had their sutures adjusted demonstrated a smaller mean post-operative deviation (8.5 PD) than those patients in whom their suture was not adjusted (mean = 16.3 PD).

Conclusion

Our study displays a trend that adjustable procedures are more effective in terms of the mean horizontal effect per muscle operated, and is a novel way of reporting effectiveness of strabismus procedures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Nihalani BR, Hunter DG (2011) Adjustable suture strabismus surgery. Eye 25:1262–1276

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  2. Haridas A, Sundaram V (2005) Adjustable versus non-adjustable sutures for strabismus. Cochrane Database Syst Rev. doi:10.1002/14651858.CD004240.pub2

    PubMed  Google Scholar 

  3. Zhang MS, Hutchinson AK, Drack AV, Cleveland J, Lambert SR (2012) Improved ocular alignment with adjustable sutures in adults undergoing strabismus surgery. Ophthalmology 119:396–402

    Article  PubMed  Google Scholar 

  4. Mireskandari K, Cotesta M, Schofield J, Kraft SP (2012) Utility of adjustable sutures in primary strabismus surgery and reoperations. Ophthalmology 119:629–633

    Article  PubMed  Google Scholar 

  5. Liebermann L (2013) Adjustment versus no adjustment when using adjustable sutures in strabismus surgery. J Am Assoc Pediatr Ophthalmol Strabismus 17(1):38–42

    Article  Google Scholar 

  6. Weston B, Enzenauer RW, Kraft SP et al (1991) Stability of the post operative alignment in adjustable-suture strabismus surgery. J Pediatr Ophthalmol Strabismus 28:206–211

    CAS  PubMed  Google Scholar 

  7. Pratt-Johnson JA (1985) Adjustable suture strabismus surgery: a review of 255 consecutive cases. Can J Ophthalmol 208:105–108

    Google Scholar 

  8. Tripathi A, Haslett R, Marsh IB (2003) Strabismus surgery: adjustable sutures-good for all? Eye 17:739–742

    Article  CAS  PubMed  Google Scholar 

  9. Bishop F, Doran RML (2004) Adjustable and non-adjustable strabismus surgery: a retrospective case-matched study. Strabismus 12(1):3–11

    Article  CAS  PubMed  Google Scholar 

  10. Idrees Z, Dooley I, Fahy G (2014) Horizontal strabismus surgical outcomes in a teaching hospital. Ir Med J 107(6):176–178

    CAS  PubMed  Google Scholar 

  11. Wisnicki HJ, Repka MX, Guyton DL (1988) Reoperation rate in adjustable strabismus surgery. J Pediatr Ophthalmol Strabismus 25(3):112–114

    CAS  PubMed  Google Scholar 

  12. Budning AS, Day C, Nguyen A (2010) The short adjustable suture. Can J Ophthalmol 45:359–362

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors have no financial interest in this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alex Ferdi.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ferdi, A., Kelly, R., Logan, P. et al. Outcomes of adjustable strabismus surgery in an Irish University Hospital. Int Ophthalmol 37, 1215–1219 (2017). https://doi.org/10.1007/s10792-016-0390-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10792-016-0390-5

Keywords

Navigation