Skip to main content
Log in

Experimental Study of the Effects of Installation of Sand Columns in Compressible Clay Using a Reduced Model

  • Original Paper
  • Published:
Geotechnical and Geological Engineering Aims and scope Submit manuscript

Abstract

The present study focuses on the investigation of the behaviour of a reduced model of a reinforced soil massif by a sand column tested in the laboratory. These tests involved the installation of sand columns in clay specimens (kaolin) by different methods. The specimens thus obtained are subjected to the same oedometric loading program. The first part of this work aims to study the effect of the intensity of the compaction stress of the sand columns on the surrounding soil and the effect on the behaviour of the soil-column massif. The sand columns were installed with the soil replacement method and with compacting of the columns (WR_WC). Three different compaction stresses were used to install the columns. In the second part, a sand column 20 mm in diameter was installed by two methods: one with replacement of the soil (WR) and without compaction and the other with displacement of the soil (WD). A comparison between the two methods has been established. By determining the equivalent characteristics for the soil-column massif, this study made it possible to characterize the effect of the installation method of the columns on the settlements, the void ratioe of kaolin, the equivalent void ratio eeq of the massif soil-column and on the compressibility parameters of the massif (equivalent compression index Cceq and swelling index Cseq), by comparing the results obtained with those of the unreinforced soils that constitute the reference case. The results obtained showed that the techniques used for the installation of columns have significant effects on the behaviour of reinforced massifs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16

Similar content being viewed by others

References

  • Aboshi H, Ichimoto E, Harada K, Emoki M (1979) The composer—a method to improve the characteristics of soft clays by inclusion of large diameter sand columns. In: Proceeding of interactional conference on soil reinforcement E.N.P.C., 1, Paris 211–216

  • Ambily AP, Grandhi SR (2007) Behavior of stone columns based on experimental and FEM analysis. J GeotechGeoenvironEng ASCE 133(4):405–415

    Google Scholar 

  • Balaam NP, Booker JR (1985) Effect of stone column yield on settlement of rigid foundations in stabilized clay. Int J Num Anal Meth Geomech 9(4):331–351

    Article  Google Scholar 

  • Balaam NP, Poulos HG, Brown PT (1978) Settlement analysis of soft clays reinforced with granular piles. In: Proceeding of the 5th Asian conference on soil reinforcement, Bangkok, Thailand, 81–92

  • Black J, Sivakumar V, Madhav M, McCabe B (2006) An improved experimental test set-up to study the performance of granular columns. Geotech Test J 29(3):193–199

    Google Scholar 

  • Black J, Sivakumar V, McKinley JD (2007) Performance of clay samples reinforced with vertical granular columns. Can Geotech J 44(1):89–95

    Article  Google Scholar 

  • Castro J, Karstunen M (2010) Numerical simulations of stone column installation. Can Geotech J 47(10):1127–1138

    Article  Google Scholar 

  • Castro J, Sagaseta C (2009) Consolidation around stone columns. Influence of column deformation. Int J Numer Anal Meth Geomech 33(7):851–877

    Article  Google Scholar 

  • Castro J, Karstunen M, Sivasithamparam N (2014) Influence of stone column installation on settlement reduction. Comput Geotech 59:87–97

    Article  Google Scholar 

  • Corneille S (2007) Etude du comportement mécanique des colonnes ballastées chargées par des semelles rigides, Thèse de doctorat, Institut national polytechnique de Lorraine

  • Dhouib A, Blondeau F (2005) Colonnes Ballastées. Presses de l’École National des Ponts et Chaussées, Paris

    Google Scholar 

  • Elshazly HA, Hafez D, Mosaad M (2006) Back calculating vibro-installation stresses in stone columns reinforced grounds. Proc ICE Ground Improv 10(2):47–53

    Article  Google Scholar 

  • Elshazly H, Elkasabgy M, Elleboudy A (2008) Effect of intercolumn spacing on soil stresses due to vibro-installed stone columns:interesting findings. Geotech Geol Eng 26(2):225–236

    Article  Google Scholar 

  • Foray P, Flavigny E, Nguyen NT, Lambert S, Briançon L (2009) Modélisation numérique 3D de colonnes ballastées et application. In Proceedings of the 17th international conference on soil mechanics and geotechnical engineering–ICSMGE.

  • Greenwood DA (1970) Mechanical improvement of soils below ground surfaces. In: Proceedings of the ground engineering conference on institution of civil engineers, London. pp 11–22

  • Guetif Z, Bouassida M, Debats JM (2007) Improved Soft Clay Characteristics Due to Stone Column Installation. Comput Geotech 34(2):104–111

    Article  Google Scholar 

  • Han J, Ye SL (1992) Settlement analysis of buildings on the soft clays stabilized by stone columns. In: Proceedings of the international conference on soil improvement and pile found, vol 118, pp 446–451

  • Han J, Ye SL (2001) Simplified method for consolidation rate of stone column reinforced foundation. J Geotech Geoenviron Eng 127(7):597–603

    Article  Google Scholar 

  • Hughes JMO, Withers NJ, Greenwood DA (1976) A field trial of reinforcing effect of stone column in soil. In: Proceedings of the ground treatment by deep compaction, Institution of Civil Engineers, London. pp 32–44

  • Kirsch F (2006) Vibro stone column installation and its effect on ground improvement. In: Proceedings of the international conference on numerical modeling of construction processes in geotechnical engineering for urban environment. Taylor and Francis, Bochum, Germany, pp 115–124

  • Nguyen N-T (2008) Modélisation du comportement des fondations profondes dans les argiles molles. Thèse de doctorat, institut polytechnique de Grenoble

  • Phan VTP (2010) Renforcement des sols compressibles par colonnes ballastées. Thèse de doctorat, Université Européenne de Bretagne—INSA de Rennes

  • Priebe HJ (1976) Abschactzung des setzungsverhaltnseiensdurchstopfverdichtungverbessertenbaugrundees. Die Bautechnik 54:160–162 ((in german))

    Google Scholar 

  • Priebe HJ (1995) The design of vibro replacement. Ground Eng 28:31–37

    Google Scholar 

  • Sivakumar V, McKelvey D, Graham J, Hughes D (2004) Triaxial tests on model sand columns in clay. Can Geotech J 41:299–312

    Article  Google Scholar 

  • Six V (2006) Analyse du comportement des colonnes ballastées : influence des conditions initiales. Thèse de doctorat, Université des sciences et technologies de Lille

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohamed Laouche.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Laouche, M., Karech, T., Rangeard, D. et al. Experimental Study of the Effects of Installation of Sand Columns in Compressible Clay Using a Reduced Model. Geotech Geol Eng 39, 2301–2312 (2021). https://doi.org/10.1007/s10706-020-01626-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10706-020-01626-6

Keywords

Navigation