Skip to main content
Log in

Echocardiography and magnetic resonance imaging based strain analysis of functional single ventricles: a study of intra- and inter-modality reproducibility

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

The purpose of this study was to measure reproducibility in strain measurements by echocardiography and cardiac magnetic resonance imaging (CMR) in functional single ventricles in the Fontan circulation. Fontan echocardiograms and CMRs between 1/2005 and 6/2013 were analyzed retrospectively. Patients were included if studies occurred <1 year apart and without interim catheter-based or surgical intervention. Global peak systolic circumferential (GCS) and longitudinal (GLS) strain, and strain rates (GCSR and GLSR) were measured by speckle or feature tracking (echocardiogram vs. CMR) using commercial software. 134 study pairs were identified; 74 with dominant left and 60 with dominant right ventricles. Agreement for strain and strain rate between echocardiogram and CMR was modest for circumferential measurements, concordance correlation coefficient (Rc) = 0.56 for GCS, 0.44 for GCSR; and low for longitudinal measurements, Rc = 0.34 for GLS, and 0.27 for GLSR. There was good inter-observer agreement (n = 30) for strain measurements by echocardiogram and CMR (echocardiogram GCS Rc = 0.84, echocardiogram GLS Rc = 0.79, CMR GCS Rc = 0.94, CMR GLS Rc = 0.75). Inter-observer agreement for strain rate was slightly lower (echocardiogram GCSR Rc = 0.79, echocardiogram GLSR Rc = 0.73, CMR GCSR Rc = 0.93, CMR GLSR Rc = 0.54). Coefficients for intra-observer agreement for these variables were similar to inter-observer agreement. In conclusion, intra-modality reproducibility for strain assessment in functional single ventricles in the Fontan circulation is high, measured both by echocardiography and CMR; inter-modality reproducibility, however, is modest. These findings caution against mixing values from multiple modalities in the long-term assessment of patient health in this population.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Piran S, Veldtman G, Siu S et al (2002) Heart failure and ventricular dysfunction in patients with single or systemic right ventricles. Circulation 105:1189–1194. doi:10.1161/hc1002.105182

    Article  PubMed  Google Scholar 

  2. Lasa JJ, Glatz AC, Daga A, Shah M (2014) Prevalence of arrhythmias late after the Fontan operation. Am J Cardiol 113:1184–1188. doi:10.1016/j.amjcard.2013.12.025

    Article  PubMed  Google Scholar 

  3. Friedberg MK, Silverman NH, Dubin AM, Rosenthal DN (2007) Right ventricular mechanical dyssynchrony in children with hypoplastic left heart syndrome. J Am Soc Echocardiogr 20:1073–1079. doi:10.1016/j.echo.2007.02.015

    Article  PubMed  Google Scholar 

  4. Margossian R, Schwartz ML, Prakash A et al (2009) Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study). Am J Cardiol 104:419–428. doi:10.1016/j.amjcard.2009.03.058

    Article  PubMed  PubMed Central  Google Scholar 

  5. Kalam K, Otahal P, Marwick TH (2014) Prognostic implications of global LV dysfunction: a systematic review and meta-analysis of global longitudinal strain and ejection fraction. Heart Br Card Soc 100:1673–1680. doi:10.1136/heartjnl-2014-305538

    Google Scholar 

  6. Abraham TP, Dimaano VL, Liang H-Y (2007) Role of tissue Doppler and strain echocardiography in current clinical practice. Circulation 116:2597–2609. doi:10.1161/CIRCULATIONAHA.106.647172

    Article  PubMed  Google Scholar 

  7. Singh GK, Cupps B, Pasque M et al (2010) Accuracy and reproducibility of strain by speckle tracking in pediatric subjects with normal heart and single ventricular physiology: a two-dimensional speckle-tracking echocardiography and magnetic resonance imaging correlative study. J Am Soc Echocardiogr 23:1143–1152. doi:10.1016/j.echo.2010.08.010

    Article  PubMed  PubMed Central  Google Scholar 

  8. Schmidt R, Orwat S, Kempny A et al (2013) Value of speckle-tracking echocardiography and MRI-based feature tracking analysis in adult patients after Fontan-type palliation. Congenit Heart Dis 9:397–406. doi:10.1111/chd.12156

    Article  PubMed  Google Scholar 

  9. Rathod RH, Prakash A, Powell AJ, Geva T (2010) Myocardial fibrosis identified by cardiac magnetic resonance late gadolinium enhancement is associated with adverse ventricular mechanics and ventricular tachycardia late after Fontan operation. J Am Coll Cardiol 55:1721–1728. doi:10.1016/j.jacc.2009.12.036

    Article  PubMed  PubMed Central  Google Scholar 

  10. Rathod RH, Prakash A, Kim YY et al (2014) Cardiac magnetic resonance parameters predict transplantation-free survival in patients with fontan circulation. Circ Cardiovasc Imaging 7:502–509. doi:10.1161/CIRCIMAGING.113.001473

    Article  PubMed  PubMed Central  Google Scholar 

  11. Lin LI-K (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268. doi:10.2307/2532051

    Article  CAS  PubMed  Google Scholar 

  12. Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310

    Article  CAS  PubMed  Google Scholar 

  13. Khoo NS, Smallhorn JF, Kaneko S et al (2013) The assessment of atrial function in single ventricle hearts from birth to Fontan: a speckle-tracking study by using strain and strain rate. J Am Soc Echocardiogr 26:756–764. doi:10.1016/j.echo.2013.04.005

    Article  PubMed  Google Scholar 

  14. Schlangen J, Petko C, Hansen JH et al (2014) Two-dimensional global longitudinal strain rate is a preload independent index of systemic right ventricular contractility in hypoplastic left heart syndrome patients after Fontan operation. Circ Cardiovasc Imaging 7:880–886. doi:10.1161/CIRCIMAGING.114.002110

    Article  PubMed  Google Scholar 

  15. Ghelani SJ, Harrild DM, Gauvreau K et al (2015) Comparison between echocardiography and cardiac magnetic resonance imaging in predicting transplant-free survival after the Fontan operation. Am J Cardiol 116:1132–1138. doi:10.1016/j.amjcard.2015.07.011

    Article  PubMed  Google Scholar 

  16. Moiduddin N, Texter KM, Zaidi AN et al (2010) Two-dimensional speckle strain and dyssynchrony in single right ventricles versus normal right ventricles. J Am Soc Echocardiogr 23:673–679. doi:10.1016/j.echo.2010.03.028

    Article  PubMed  Google Scholar 

  17. Moiduddin N, Texter KM, Zaidi AN et al (2010) Two-dimensional speckle strain and dyssynchrony in single left ventricles vs. normal left ventricles. Congenit Heart Dis 5:579–586. doi:10.1111/j.1747-0803.2010.00460.x

    Article  PubMed  Google Scholar 

  18. Lunze FI, Lunze K, McElhinney DB et al (2013) Heterogeneity of regional function and relation to ventricular morphology in patients with fontan circulation. Am J Cardiol 112:1207–1213. doi:10.1016/j.amjcard.2013.06.016

    Article  PubMed  Google Scholar 

  19. Menon SC, Minich LL, Casper TC et al (2011) Regional myocardial dysfunction following Norwood with right ventricle to pulmonary artery conduit in patients with hypoplastic left heart syndrome. J Am Soc Echocardiogr 24:826–833. doi:10.1016/j.echo.2011.05.008

    Article  PubMed  Google Scholar 

  20. Tham EB, Smallhorn JF, Kaneko S et al (2014) Insights into the evolution of myocardial dysfunction in the functionally single right ventricle between staged palliations using speckle-tracking echocardiography. J Am Soc Echocardiogr 27:314–322. doi:10.1016/j.echo.2013.11.012

    Article  PubMed  Google Scholar 

  21. Li S-J, Wong SJ, Cheung Y (2014) Atrial and ventricular mechanics in patients after Fontan-type procedures: atriopulmonary connection versus extracardiac conduit. J Am Soc Echocardiogr 27:666–674. doi:10.1016/j.echo.2014.01.027

    Article  PubMed  Google Scholar 

  22. Onishi T, Saha SK, Delgado-Montero A et al (2015) Global longitudinal strain and global circumferential strain by speckle-tracking echocardiography and feature-tracking cardiac magnetic resonance imaging: comparison with left ventricular ejection fraction. J Am Soc Echocardiogr 28:587–596. doi:10.1016/j.echo.2014.11.018

    Article  PubMed  Google Scholar 

  23. Voigt J-U, Pedrizzetti G, Lysyansky P et al (2015) Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging 16:1–11. doi:10.1093/ehjci/jeu184

    Article  CAS  PubMed  Google Scholar 

Download references

Funding

This study was supported by the Higgins Family Noninvasive Cardiac Imaging Research Funds.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rahul H. Rathod.

Ethics declarations

Conflict of interest

None of the authors have relevant conflicts of interest to disclose.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional Committee on Clinical Investigations and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed consent

The institutional Committee on Clinical Investigations approved this retrospective study and waived the requirement for informed consent.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ghelani, S.J., Harrild, D.M., Gauvreau, K. et al. Echocardiography and magnetic resonance imaging based strain analysis of functional single ventricles: a study of intra- and inter-modality reproducibility. Int J Cardiovasc Imaging 32, 1113–1120 (2016). https://doi.org/10.1007/s10554-016-0882-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-016-0882-4

Keywords

Navigation