Abstract
Interictal epileptiform discharges (IEDs) can produce haemodynamic responses that can be detected by electroencephalography-functional magnetic resonance imaging (EEG-fMRI) using different analysis methods such as the general linear model (GLM) of IEDs or independent component analysis (ICA). The IEDs can also be mapped by electrical source imaging (ESI) which has been demonstrated to be useful in presurgical evaluation in a high proportion of cases with focal IEDs. ICA advantageously does not require IEDs or a model of haemodynamic responses but its use in EEG-fMRI of epilepsy has been limited by its ability to separate and select epileptic components. Here, we evaluated the performance of a classifier that aims to filter all non-BOLD responses and we compared the spatial and temporal features of the selected independent components (ICs). The components selected by the classifier were compared to those components selected by a strong spatial correlation with ESI maps of IED sources. Both sets of ICs were subsequently compared to a temporal model derived from the convolution of the IEDs (derived from the simultaneously acquired EEG) with a standard haemodynamic response. Selected ICs were compared to the patients’ clinical information in 13 patients with focal epilepsy. We found that the misclassified ICs clearly related to IED in 16/25 cases. We also found that the classifier failed predominantly due to the increased spectral range of fMRIs temporal responses to IEDs. In conclusion, we show that ICA can be an efficient approach to separate responses related to epilepsy but that contemporary classifiers need to be retrained for epilepsy data. Our findings indicate that, for ICA to contribute to the analysis of data without IEDs to improve its sensitivity, classification strategies based on data features other than IC time course frequency is required.
Similar content being viewed by others
References
Aghakhani Y, Kobayashi E, Bagshaw AP, Hawco C, Bénar CG, Dubeau F, Gotman J (2006) Cortical and thalamic fMRI responses in partial epilepsy with focal and bilateral synchronous spikes. Clin Neurophysiol 117:177–191
Allen PJ, Polizzi G, Krakow K, Fish DR, Lemieux L (1998) Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction. Neuroimage 8(3):229–239
Allen PJ, Josephs O, Turner R (2000) A method for removing imaging artifact from continuous EEG recorded during functional MRI. Neuroimage 12(2):230–239
Bagshaw AP, Kobayashi E, Dubeau F, Pike GB, Gotman J (2006) Correspondence between EEG-fMRI and EEG dipole localization of interictal discharges in focal epilepsy. Neuroimage 30:417–425
Bénar CG, Gross DW, Wang YH, Petre V, Pike B, Dubeau F, Gotman J (2002) The BOLD response to interictal epileptiform discharges. NeuroImage 17:1182–1192
Bénar CG, Grova C, Kobayashi E, Bagshaw AP, Aghakhani Y, Dubeau F, Gotman J (2006) EEG-fMRI of epileptic spikes: concordance with EEG source localization and intracranial EEG. Neuroimage 30:1161–1170
Boor R, Jacobs J, Hinzmann A, Bauermann T, Scherg M, Boor S, Vucurevic G, Pfleiderer C, Kutschke G, Stoeter P (2007) Combined spike-related functional MRI and multiple source analysis in the non-invasive spike localization of benign rolandic epilepsy. Clin Neurophysiol 118:901–909
Brodbeck V, Spinelli L, Lascano AM, Wissmeier M, Vargas MI, Vulliemoz S, Pollo C, Schaller K, Michel CM, Seeck M. (2011) Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients. Brain 134: 2887–2897
Calhoun V, Adali T, Hansen L, Larsen J, Pekar J (2003) Ica of functional mri data: an overview, 4th International Symposium on Independent Component Analysis and Blind Signal Separation (ICA 2003)
De Martino F, Gentile F, Esposito F, Balsi M, Di Salle F, Goebel R, Formisano E (2007) Classification of fMRI independent components using IC-fingerprints and support vector machine classifiers. Neuroimage 34(1):177–194
Diehl B, Salek-Haddadi A, Fish DR, Lemieux L (2003) Mapping of spikes, slow waves, and motor tasks in a patient with malformation of cortical development using simultaneous EEG and fMRI. Magn Reson Imaging 21(10):1167–1173 Friston KJ, Holmes AP, Worsley KJ, Poline JB, Frith C, Frackowiak RSJ (1995) Statistical Parametric Maps in Functional Imaging: A General Linear Approach. Human Brain Mapping, 2: 189-210
Friston KJ, Holmes AP, Worsley KJ, Poline JB, Frith C, Frackowiak RSJ (1995) Statistical parametric maps in functional imaging: a general linear approach. Human Brain Mapping 2:189–210
Fox MD, Snyder AZ, Vincent JL, Corbetta M, Van Essen DC, Raichle ME (2005) The human brain is intrinsically organized into dynamic, anticorrelated functional networks. Proc Natl Acad Sci USA 102(27):9673–9678
Glover GH (1999) Deconvolution of impulse response in eventrelated BOLD fMRI. Neuroimage 9:416–429
Gotman J, Kobayashi E, Bagshaw AP, Benar CG, Dubeau F (2006) Combining EEG and fMRI: a multimodal tool for epilepsy research. J Magn Reson Imaging 23(6):906–920
Greicius MD, Krasnow B, Reiss AL, Menon V (2003) Functional connectivity in the resting brain: a network analysis of the default mode hypothesis. Proc Natl Acad Sci USA 100(1):253–258
Grouiller F, Thornton RC, Groening K, Spinelli L, Duncan JS, Schaller K, Siniatchkin M, Lemieux L, Seeck M, Michel CM, Vulliemoz S (2011) With or without spikes: localization of focal epileptic activity by simultaneous electroencephalography and functional magnetic resonance imaging. Brain. doi:10.1093/brain/awr156
Grova C, Daunizeau J, Kobayashi E, Bagshaw AP, Lina JM, Dubeau F, Gotman J (2008) Concordance between distributed EEG source localization and simultaneous EEG-fMRI studies of epileptic spikes. Neuroimage 39:755–774
Hamandi K, Salek-Haddadi A, Fish DR, Lemieux L (2004) EEG/functional MRI in epilepsy: the Queen Square experience. J Clin Neurophysiol 21(4):241–248
Helmholtz H (1853) Ueber einige Gesetze der Vertheilung elektrischer Ströme in körperlichen Leitern mit Anwendung auf die thierisch-elektrischen Versuche. Ann Physik und Chemie 9:211–233
Hunyadi B, Tousseyn S, Mijović B, Dupont P, Van Huffel S, Van Paesschen W, De Vos M (2013) ICA extracts epileptic sources from fMRI in EEG-negative patients: a retrospective validation study. PLoS One 8(11):e78796. doi:10.1371/journal.pone.0078796
Isnard J, Guénot M, Ostrowsky K, Sindou M, Mauguière F (2000) The role of the insular cortex in temporal lobe epilepsy. Ann Neurology 48:614–623
Kim SG, Ogawa S (2012) Biophysical and physiological origins of blood oxygenation level-dependent fMRI signals. J. Cereb. Blood Flow Metab. 32:1188–1206
Lantz G, Spinelli L, Seeck M, Menendez GPR, Sottas CC, Michel CM (2003) Propagation of interictal epileptiform activity can lead to erroneous source localizations: a 128-channel EEG mapping study. J Clin Neurophysiol 20:311–319
Lemieux L, Salek-Haddadi A, Josephs O, Allen P, Toms N, Scott C, Krakow K, Turner R, Fish DR (2001) Event-related fMRI with simultaneous and continuous EEG: description of the method and initial case report. Neuroimage 14:780–787
LeVan P, Tyvaert L, Moeller F, Gotman J (2010) Independent component analysis reveals dynamic ictal BOLD responses in EEG-fMRI data from focal epilepsy patients. NeuroImage 49:366–378
Maziero D, Castellanos AJ, Salmon CEG, Velasco TR (2014) Comparison between different ESI methods on refractory epilepsy patients shows a high sensitivity for bayesian model averaging. Journal of Biomedical Science and Engineering 7:662–674
McKeown M, Makeig S, Brown G, Jung T, Kindermann S, Bell A, Sejnowski T (1998) Analysis of fMRI data by blind separation into independent spatial components. Hum Brain Mapp 6:160–188
Menz M, Neumann J, Muller K, Zysset S (2006) Variability of the BOLD response over time: an examination of within-session differences. Neuroimage 32:1185–1194
Michel CM, Murray MM, Lantz G, Gonzalez S, Spinelli L, Peralta RG (2004) EEG source imaging. Clin Neurophysiol 115:2195–2222
Moeller F, LeVan P, Gotman J (2011) Independent component analysis (ICA) of generalized spike wave discharges in fMRI: comparison with general linear model-based EEG-fMRI. Hum Brain Mapp 32:209–217
Moritz CH, Carew JD, McMillan AB, Meyerand ME (2005) Independent component analysis applied to self-paced functional MR imaging paradigms. Neuroimage 25:181–192
Pittau F, Dubeau F, Gotman J (2012) Contribution of EEG/fMRI to the definition of the epileptic focus. Neurology 78:1479–1487
Rodionov R, De Martino F, Laufs H, Carmichael DW, Formisano E, Walker M, Duncan J, Lemieux L (2007) Independent component analysis of interictal fMRI in focal epilepsy: comparison with general linear model-based EEG correlated fMRI. Neuroimage 38:488–500
Salek-Haddadi A, Friston KJ, Lemieux L, Fish DR (2003) Studying spontaneous EEG activity with fMRI. Brain Res Rev 43:110–133
Salek-Haddadi A, Diehl B, Hamandi K, Merschhemke M, Liston A, Friston K, Duncan JS, Fish DR, Lemieux L (2006) Hemodynamic correlates of epileptiform discharges: an EEG–fMRI study of 63 patients with focal epilepsy. Brain Res 1088(1):148–166
Schmithorst VJ, Brown RD (2004) Empirical validation of the triple-code model of numerical processing for complex math operations using functional MRI and group Independent 150 Part 3. Multimodal data integration component analysis of the mental addition and subtraction of fractions. Neuroimage 22:1414–1420
Seeck M, Lazeyras F, Michel CM, Blanke O, Gericke CA, Ives J, Delavelle J, Golay X, Haenggeli CA, de Tribolet N, Landis T (1998) Non-invasive epileptic focus localization using EEGtriggered functional MRI and electromagnetic tomography. Electroencephalogr Clin Neurophysiol 106:508–512
Thornton R, Vulliemoz S, Rodionov R, Carmichael DW, Chaudhary UJ, Diehl B, Laufs H, Vollmar C, McEvoy AW, Walker MC, Bartolomei F, Guye M, Chauvel P, Duncan JS, Lemieux L (2011) Epileptic networks in focal cortical dysplasia revealed using electroencephalography-functional magnetic resonance imaging. Ann Neurol 70:822–837
Trujillo-Barreto NJ, Aubert-Vázquez E, Valdés-Sosa PA (2004) Bayesian model averaging in EEG/MEG imaging. Neuroimage 21:1300–1319
Velasco TR, Wichert-Ana L, Mathern GW, Araujo D, Walz R, Bianchin MM, Dalmagro CL, Leite JP, Santos AC, Jr Assirati, Joao A, Jr Carlotti, Carlos EGS, Sakamoto AC (2011) Utility of ictal SPECT in mesial temporal lobe epilepsy with hippocampal atrophy: a randomized trial. Neurosurgery 68(2):431–436
Vulliemoz S, Thornton R, Rodionov R, Carmichael DW, Guye M, Lhatoo S, Salek-Haddadi A, Diehl B, Hamandi K, Merschhemke M, Liston A, Friston K, Duncan JS, Fish DR, Lemieux L (2009) The spatio-temporal mapping of epileptic networks: combination of EEG–fMRI and EEG source imaging. Neuroimage 46(3):834–843
Worsley KJ, Liao CH, Aston J, Petre V, Duncan GH, Morales F, Evans AC (2002) A general statistical analysis for fMRI data. Neuroimage 15:1–15
Acknowledgments
We thank the State of São Paulo Research Foundation for the financial support. DWC is supported by the UK Engineering and Physical Sciences Research Council (EP/M001393/1) and Action Medical Research (GN2214).
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Maziero, D., Sturzbecher, M., Velasco, T.R. et al. A Comparison of Independent Component Analysis (ICA) of fMRI and Electrical Source Imaging (ESI) in Focal Epilepsy Reveals Misclassification Using a Classifier. Brain Topogr 28, 813–831 (2015). https://doi.org/10.1007/s10548-015-0436-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10548-015-0436-4