Abstract
The purpose of this investigation was to evaluate the performance of the Bactec 9240 and BacT/Alert 3D blood culture systems in the detection of Candida spp. and bacteria in simulated polymicrobial sepsis models. A total of 28 clinical isolates of Escherichia coli, Staphylococcus aureus, Candida albicans, and Candida glabrata were studied. Five polymicrobial models of C. albicans + S. aureus, C. albicans + E. coli, C. glabrata + S. aureus, C. glabrata + E. coli, and C. albicans + C. glabrata were prepared. Each combination was inoculated in five different blood culture vials. The two systems were compared for culture positivity and time to detection (TTD). Twenty-four mixed cultures with a yeast and a bacteria were tested. Bactec Mycosis vials could detect yeasts in all 24 cultures. The aerobic vials from both Bactec and BacT/Alert could detect both yeasts and bacteria in 22/24 (91.66 %) cultures. Bactec Plus Anaerobic/F and BacT/Alert FN vials could detect both microorganisms in 19/24 (79.16 %) and 4/24 (16.67 %) vials, respectively. Seven polymicrobial sepsis models with C. albicans + C. glabrata were also tested. Mycosis vials could detect both yeasts in 7/7 mixed cultures. The aerobic vials from Bactec and BacT/Alert could detect both yeasts in 3/7 and 2/7 mixed cultures, respectively. Bactec Plus Aerobic/F had a shorter TTD compared to BacT/Alert FA and Bactec Plus Anaerobic/F vials (p < 0.0001 and p < 0.01, respectively). The present study shows that the Bactec and BacT/Alert systems have different characteristics in the detection of yeasts and bacteria with polymicrobial sepsis.
Similar content being viewed by others
References
Klotz SA, Chasin BS, Powell B, Gaur NK, Lipke PN (2007) Polymicrobial bloodstream infections involving Candida species: analysis of patients and review of the literature. Diagn Microbiol Infect Dis 59:401–406
Arendrup MC, Sulim S, Holm A, Nielsen L, Nielsen SD, Knudsen JD, Drenck NE, Christensen JJ, Johansen HK (2011) Diagnostic issues, clinical characteristics, and outcomes for patients with fungemia. J Clin Microbiol 49:3300–3308
Tortorano AM, Peman J, Bernhardt H, Klingspor L, Kibbler CC, Faure O, Biraghi E, Canton E, Zimmermann K, Seaton S, Grillot R; ECMM Working Group on Candidaemia (2004) Epidemiology of candidaemia in Europe: results of 28-month European Confederation of Medical Mycology (ECMM) hospital-based surveillance study. Eur J Clin Microbiol Infect Dis 23:317–322
Martin GS, Mannino DM, Eaton S, Moss M (2003) The epidemiology of sepsis in the United States from 1979 through 2000. N Engl J Med 348:1546–1554
McKenzie FE (2006) Case mortality in polymicrobial bloodstream infections. J Clin Epidemiol 59:760–761
Morrell M, Fraser VJ, Kollef MH (2005) Delaying the empiric treatment of Candida bloodstream infection until positive blood culture results are obtained: a potential risk factor for hospital mortality. Antimicrob Agents Chemother 49:3640–3645
Garey KW, Rege M, Pai MP, Mingo DE, Suda KJ, Turpin RS, Bearden DT (2006) Time to initiation of fluconazole therapy impacts mortality in patients with candidemia: a multi-institutional study. Clin Infect Dis 43:25–31
Taur Y, Cohen N, Dubnow S, Paskovaty A, Seo SK (2010) Effect of antifungal therapy timing on mortality in cancer patients with candidemia. Antimicrob Agents Chemother 54:184–190
Wilson ML, Mirrett S, Meredith FT, Weinstein MP, Scotto V, Reller LB (2001) Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults. J Clin Microbiol 39:983–989
Mirrett S, Reller LB, Petti CA, Woods CW, Vazirani B, Sivadas R, Weinstein MP (2003) Controlled clinical comparison of BacT/Alert standard aerobic medium with BACTEC standard aerobic medium for culturing blood. J Clin Microbiol 41:2391–2394
Ericson EL, Klingspor L, Ullberg M, Özenci V (2012) Clinical comparison of the Bactec Mycosis IC/F, BacT/Alert FA, and BacT/Alert FN blood culture vials for the detection of candidemia. Diagn Microbiol Infect Dis 73:153–156
Meyer MH, Letscher-Bru V, Jaulhac B, Waller J, Candolfi E (2004) Comparison of Mycosis IC/F and Plus Aerobic/F media for diagnosis of fungemia by the Bactec 9240 system. J Clin Microbiol 42:773–777
George BJ, Horvath LL, Hospenthal DR (2005) Effect of inoculum size on detection of Candida growth by the BACTEC 9240 automated blood culture system using aerobic and anaerobic media. J Clin Microbiol 43:433–435
Cateau E, Cognee AS, Tran TC, Vallade E, Garcia M, Belaz S, Kauffmann-Lacroix C, Rodier MH (2012) Impact of yeast-bacteria coinfection on the detection of Candida sp. in an automated blood culture system. Diagn Microbiol Infect Dis 72:328–321
Acknowledgments
This study was supported by grants from the Karolinska Institutet.
Conflict of interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Klingspor, L., Muhammed, S.A. & Özenci, V. Comparison of the two blood culture systems, Bactec 9240 and BacT/Alert 3D, in the detection of Candida spp. and bacteria with polymicrobial sepsis. Eur J Clin Microbiol Infect Dis 31, 2983–2987 (2012). https://doi.org/10.1007/s10096-012-1650-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10096-012-1650-6